Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Am Heart J ; 264: 114-122, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37315878

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as a standard treatment for high-operative risk patients with severe aortic stenosis (AS). Although coronary artery disease (CAD) often coexists with AS, clinical and angiographic evaluations of stenosis severity are unreliable in this specific setting. To provide precise risk stratification of coronary lesions, combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) was developed to integrate morphological and molecular information on plaque composition. However, there is a lack of evidence on the association between NIRS-IVUS derived findings such as maximum 4mm lipid core burden index (maxLCBI4mm) and clinical outcomes in AS patients undergoing TAVI. This registry aims to assess feasibility and safety of NIRS-IVUS imaging in the setting of routine pre-TAVI coronary angiography to improve assessment of CAD severity. METHODS: The registry is designed as a non-randomized, prospective, observational, multicenter cohort registry. Patients referred for TAVI with angiographic evidence of CAD receive NIRS-IVUS imaging and are followed up to 24 months. Enrolled patients are classified as NIRS-IVUS positive and NIRS-IVUS negative, respectively, based on their maxLCBI4mm to compare their clinical outcomes. The primary endpoint of the registry is major adverse cardiovascular events over a 24-month follow-up period. CONCLUSIONS: Identification of patients likely or unlikely to benefit from revascularization prior to TAVI represents an important unmet clinical need. This registry is designed to investigate whether NIRS-IVUS-derived atherosclerotic plaque characteristics can identify patients and lesions at risk for future adverse cardiovascular events after TAVI, in order to refine interventional decision-making in this challenging patient population.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Angiografia Coronária , Sistema de Registros
2.
Int J Cardiovasc Imaging ; 37(10): 3049-3055, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34247318

RESUMO

MR imaging with an albumin-binding probe enables the visualization of endothelial permeability and damage in the arterial system. The goal of this study was to compare signal enhancement of lesions with different grades of stenosis segments on molecular CMR in combination with the albumin-binding probe gadofosveset. This prospective clinical study included patients with symptoms suggestive of coronary artery disease (CAD). Patients underwent gadofosveset-enhanced cardiovascular magnetic resonance (CMR) imaging and x-ray angiography (QCA) within 24 h. CMR imaging was performed prior to and 24 h following the administration of gadofosveset. Contrast-to-noise ratios (CNRs) between segments with different grades of stenosis were compared. Overall, n = 203 segments of 26 patients were included. Lesions with more than > 70% stenosis demonstrated significantly higher CNRs compared to lesions < 70% (7.6 ± 8.3 vs. 2.5 ± 4.9; p < 0.001). Post-stenotic segments of lesions > 70% stenosis showed significant higher signal enhancement compared to segments located upstream of these lesions (7.3 ± 8.8 vs. 2.8 ± 2.2; p = 0.02). No difference in signal enhancement between segments proximal and distal of lesions with stenosis greater than 50% was measured (3.3 ± 2.8 vs. 2.4 ± 2.7; p = 0.18). ROC analysis for the detection of lesions ≥ 70% revealed an area under the curve of 0.774 (95% CI 0.681-0.866). This study suggests that relevant coronary stenosis and their down-stream segments are associated with increased signal enhancement on Gadofosveset-enhanced CMR, suggesting a higher endothelial permeability in these lesions. An albumin-binding MR probe could represent a novel in vivo biomarker for the identification and characterization of these vulnerable coronary segments.


Assuntos
Estenose Coronária , Imageamento por Ressonância Magnética , Albuminas , Constrição Patológica , Meios de Contraste , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Humanos , Permeabilidade , Valor Preditivo dos Testes , Estudos Prospectivos
3.
Acta Radiol ; 55(5): 554-62, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24031049

RESUMO

BACKGROUND: Although a tube potential of 140 kV is available on most computed tomography (CT) scanners, its incremental diagnostic value versus 120 kV has been controversial. PURPOSE: To retrospectively evaluate the image quality and radiation exposure of cardiac computed tomography angiography (CCTA) performed at 140 kV in comparison to CCTA at 120 kV in overweight and moderately obese patients. MATERIAL AND METHODS: Eighty-eight patients who were referred for CCTA between January 2010 and May 2012 were included. Forty-four patients who were overweight or moderately obese (body mass index [BMI], 25-35 kg/m(2)) underwent CCTA with dual-source CT (DSCT) scanner at 140 kV. Forty-four match controls who underwent CCTA with DSCT at 120 kV were identified per BMI, average heart rate, scan indication, and scan acquisition mode. All scans were performed per routine protocols with direct physician supervision. Quantitative image metrics (CT attenuation, image noise, contrast-to-noise ratio [CNR], and signal-to-noise ratio [SNR] of left main [LM] and proximal right coronary artery [RCA]) were assessed. Effective radiation dose was compared between the two groups. RESULTS: Overall, all scans were diagnostic without any non-evaluable coronary segment per clinical report. 140 kV had a lower attenuation and image noise versus 120 kV (P<0.01). Both SNR and CNR of proximal coronary arteries were similar between 140 kV and 120 kV (SNR, LM P=0.93, RCA P=0.62; CNR, LM P=0.57, RCA P=0.77). 140 kV was associated with a 35.3% increase in effective radiation dose as compared with 120 kV (5.1 [3.6-8.2] vs. 3.3 [2.0-5.1] mSv, respectively; P<0.01). CONCLUSION: 140 kV CCTA resulted in similar image quality but a higher effective radiation dose in comparison to 120 kV CCTA. Therefore, in overweight and moderately obese patients, a tube potential of 120 kV may be sufficient for CCTA with diagnostic image quality.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Obesidade , Sobrepeso , Tomografia Computadorizada por Raios X/métodos , Técnicas de Imagem de Sincronização Cardíaca , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído
4.
BMC Res Notes ; 6: 158, 2013 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-23602055

RESUMO

BACKGROUND: Cardiac computed tomography angiography (CTA) is feasible for aortic valve evaluation, but retrospective gated protocols required high radiation doses for aortic valve assessment. A prospectively triggered adaptive systolic (PTAS) cardiac CT protocol was recently described in arrhythmia using second-generation dual-source CT. In this study, we sought to evaluate the feasibility of PTAS CTA to assess the aortic valve at a low radiation dose. FINDINGS: A retrospective cohort of 29 consecutive patients whom underwent PTAS protocols for clinical indications other than aortic valve assessment and whom also received echocardiography within 2 months of CT, was identified. Images were reviewed for aortic valve morphology (tricuspid/bicuspid/prosthetic) and stenosis (AS) by experienced blinded readers. Accuracy versus echocardiography and radiation doses were assessed. CONCLUSIONS: PTAS CTA protocols using second-generation dual-source CT for aortic valve evaluation are feasible at low doses. This protocol should be investigated further in larger cohorts.


Assuntos
Angiografia/métodos , Valva Aórtica/fisiopatologia , Sístole , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
5.
Int J Cardiovasc Imaging ; 29(6): 1361-70, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23526082

RESUMO

In this study, we sought to evaluate the image quality and effective radiation dose of prospectively ECG-triggered adaptive systolic (PTA-systolic) dual-source CTA versus prospectively triggered adaptive diastolic (PTA-diastolic) dual-source CTA in patients of unselected heart rate and rhythm. This retrospective cohort study consisted of 41 PTA-systolic and 41 matched PTA-diastolic CTA patients whom underwent clinically indicated 128-slice dual source CTA between December 2010 to June 2012. Image quality and motion artifact score (both on a Likert scale 1-4 with 4 being the best), effective dose, and CTDIvol were compared. The effect of heart rate (HR) and heart rate variability [HRV] on image motion artifact score and CTDIvol was analyzed with Pearson's correlation coefficient. All 82 exams were considered diagnostic with 0 non-diagnostic segments. PTA-systolic CTA patients had a higher maximum HR, wider HRV, were less likely to be in sinus rhythm, and received less beta-blocker vs. PTA-diastolic CTA patients. No difference in effective dose was observed (PTA-systolic vs. PTA-diastolic CTA: 2.9 vs. 2.2 mSv, p = 0.26). Image quality score (3.3 vs. 3.5, p < 0.05) and motion artifact score (3.5 vs. 3.8, p < 0.05) were lower in PTA-systolic CTAs than in PTA-diastolic CTAs. For PTA-systolic CTAs, an increase in HR was not associated with a negative impact on motion artifact score nor CTDIvol. For PTA-diastolic CTA, an increase in HR was associated with increased motion artifacts and CTDIvol. HRV demonstrated no correlation with motion artifact and CTDIvol for both PTA-systolic and PTA-diastolic CTAs. In conclusion, both PTA-diastolic CTA and PTA-systolic CTA yielded diagnostic examinations at unselected heart rates and rhythms with similar effective radiation, but PTA-systolic CTA resulted in more consistent radiation exposure and image quality across a wide range of rates and rhythms.


Assuntos
Algoritmos , Arritmias Cardíacas/complicações , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Diástole , Eletrocardiografia , Tomografia Computadorizada Multidetectores , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sístole , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Artefatos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
6.
Eur Radiol ; 22(10): 2067-75, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22622346

RESUMO

OBJECTIVES: To systematically assess inter-technique and inter-/intra-reader variability of coronary CT angiography (CTA) to measure plaque burden compared with intravascular ultrasound (IVUS) and to determine whether iterative reconstruction algorithms affect variability. METHODS: IVUS and CTA data were acquired from nine human coronary arteries ex vivo. CT images were reconstructed using filtered back projection (FBPR) and iterative reconstruction algorithms: adaptive-statistical (ASIR) and model-based (MBIR). After co-registration of 284 cross-sections between IVUS and CTA, two readers manually delineated the cross-sectional plaque area in all images presented in random order. RESULTS: Average plaque burden by IVUS was 63.7 ± 10.7% and correlated significantly with all CTA measurements (r = 0.45-0.52; P < 0.001), while CTA overestimated the burden by 10 ± 10%. There were no significant differences among FBPR, ASIR and MBIR (P > 0.05). Increased overestimation was associated with smaller plaques, eccentricity and calcification (P < 0.001). Reproducibility of plaque burden by CTA and IVUS datasets was excellent with a low mean intra-/inter-reader variability of <1/<4% for CTA and <0.5/<1% for IVUS respectively (P < 0.05) with no significant difference between CT reconstruction algorithms (P > 0.05). CONCLUSION: In ex vivo coronary arteries, plaque burden by coronary CTA had extremely low inter-/intra-reader variability and correlated significantly with IVUS measurements. Accuracy as well as reader reliability were independent of CT image reconstruction algorithm. KEY POINTS: • IVUS is deemed the gold standard in-vivo coronary plaque assessment • But coronary CT angiography findings correlate strongly with IVUS results • Coronary CT angiography now allows plaque quantification close to IVUS • Iterative image reconstruction algorithms do not alter accuracy or reproducibility • Plaque quantification is more challenging in smaller eccentric calcified lesions.


Assuntos
Algoritmos , Angiografia Coronária/normas , Placa Aterosclerótica/diagnóstico por imagem , Ultrassonografia de Intervenção , Humanos , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA