Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Biomech Eng ; 144(9)2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35237785

RESUMO

Transluminal attenuation gradient (TAG), defined as the gradient of the contrast agent attenuation drop along the vessel, is an imaging biomarker that indicates stenosis in the coronary arteries. The transluminal attenuation flow encoding (TAFE) equation is a theoretical platform that quantifies blood flow in each coronary artery based on computed tomography angiography (CTA) imaging. This formulation couples TAG (i.e., contrast dispersion along the vessel) with fluid dynamics. However, this theoretical concept has never been validated experimentally. The aim of this proof-of-principle phantom study is to validate TAFE based on CTA imaging. Dynamic CTA images were acquired every 0.5 s. The average TAFE estimated flow rates were compared against four predefined pump values in a straight (20, 25, 30, 35, and 40 ml/min) and a tapered phantom (25, 35, 45, and 55 ml/min). Using the TAFE formulation with no correction, the flow rates were underestimated by 33% and 81% in the straight and tapered phantoms, respectively. The TAFE formulation was corrected for imaging artifacts focusing on partial volume averaging and radial variation of contrast enhancement. After corrections, the flow rates estimated in the straight and tapered phantoms had an excellent Pearson correlation of r = 0.99 and 0.87 (p < 0.001), respectively, with only a 0.6%±0.2 mL/min difference in estimation of the flow rate. In this proof-of-concept phantom study, we corrected the TAFE formulation and showed a good agreement with the actual pump values. Future clinical validations are needed for feasibility of TAFE in clinical use.


Assuntos
Angiografia por Tomografia Computadorizada , Vasos Coronários , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
2.
Ann Biomed Eng ; 49(4): 1151-1168, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33067688

RESUMO

Endothelial shear stress (ESS) identifies coronary plaques at high risk for progression and/or rupture leading to a future acute coronary syndrome. In this study an optimized methodology was developed to derive ESS, pressure drop and oscillatory shear index using computational fluid dynamics (CFD) in 3D models of coronary arteries derived from non-invasive coronary computed tomography angiography (CTA). These CTA-based ESS calculations were compared to the ESS calculations using the gold standard with fusion of invasive imaging and CTA. In 14 patients paired patient-specific CFD models based on invasive and non-invasive imaging of the left anterior descending (LAD) coronary arteries were created. Ten patients were used to optimize the methodology, and four patients to test this methodology. Time-averaged ESS (TAESS) was calculated for both coronary models applying patient-specific physiological data available at the time of imaging. For data analysis, each 3D reconstructed coronary artery was divided into 2 mm segments and each segment was subdivided into 8 arcs (45°).TAESS and other hemodynamic parameters were averaged per segment as well as per arc. Furthermore, the paired segment- and arc-averaged TAESS were categorized into patient-specific tertiles (low, medium and high). In the ten LADs, used for optimization of the methodology, we found high correlations between invasively-derived and non-invasively-derived TAESS averaged over segments (n = 263, r = 0.86) as well as arcs (n = 2104, r = 0.85, p < 0.001). The correlation was also strong in the four testing-patients with r = 0.95 (n = 117 segments, p = 0.001) and r = 0.93 (n = 936 arcs, p = 0.001).There was an overall high concordance of 78% of the three TAESS categories comparing both methodologies using the segment- and 76% for the arc-averages in the first ten patients. This concordance was lower in the four testing patients (64 and 64% in segment- and arc-averaged TAESS). Although the correlation and concordance were high for both patient groups, the absolute TAESS values averaged per segment and arc were overestimated using non-invasive vs. invasive imaging [testing patients: TAESS segment: 30.1(17.1-83.8) vs. 15.8(8.8-63.4) and TAESS arc: 29.4(16.2-74.7) vs 15.0(8.9-57.4) p < 0.001]. We showed that our methodology can accurately assess the TAESS distribution non-invasively from CTA and demonstrated a good correlation with TAESS calculated using IVUS/OCT 3D reconstructed models.


Assuntos
Vasos Coronários/diagnóstico por imagem , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Idoso , Angiografia por Tomografia Computadorizada , Vasos Coronários/fisiologia , Feminino , Humanos , Hidrodinâmica , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estresse Mecânico , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA