Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 81(5): 3192-3201, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30565296

RESUMO

PURPOSE: To develop a gadolinium-free cardiac MR technique that simultaneously exploits native T1 and magnetization transfer (MT) contrast for the imaging of myocardial infarction. METHODS: A novel hybrid T one and magnetization transfer (HYTOM) method was developed based on the modified look-locker inversion recovery (MOLLI) sequence, with a train of MT-prep pulses placed before the balanced SSFP (bSSFP) readout pulses. Numerical simulations, based on Bloch-McConnell equations, were performed to investigate the effects of MT induced by (1) the bSSFP readout pulses, and (2) the MT-prep pulses, on the measured, "apparent," native T1 values. The HYTOM method was then tested on 8 healthy adult subjects, 6 patients, and a swine with prior myocardial infarction (MI). The resulting imaging contrast between normal myocardium and infarcted tissues was compared with that of MOLLI. Late gadolinium enhancement (LGE) images were also obtained for infarct assessment in patients and swine. RESULTS: Numerical simulation and in vivo studies in healthy volunteers demonstrated that MT effects, resulting from on-resonance bSSFP excitation pulses and off-resonance MT-prep pulses, reduce the measured T1 in both MOLLI and HTYOM. In vivo studies in patients and swine showed that the HYTOM sequence can identify locations of MI, as seen on LGE. Furthermore, the HYTOM method yields higher myocardium-to-scar contrast than MOLLI (contrast-to-noise ratio: 7.33 ± 1.67 vs. 3.77 ± 0.66, P < 0.01). CONCLUSION: The proposed HYTOM method simultaneously exploits native T1 and MT contrast and significantly boosts the imaging contrast for myocardial infarction.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Adulto , Idoso , Animais , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Magnetismo , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Distribuição Normal , Estudos Prospectivos , Suínos , Adulto Jovem
2.
Jpn J Radiol ; 34(2): 158-65, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26627894

RESUMO

PURPOSE: Tagged and cine magnetic resonance imaging (tMRI and cMRI) techniques are used for evaluating regional and global heart function, respectively. Measuring global function parameters directly from tMRI is challenging due to the obstruction of the anatomical structure by the tagging pattern. The purpose of this study was to develop a method for processing the tMRI images to improve the myocardium-blood contrast in order to estimate global function parameters from the processed images. MATERIALS AND METHODS: The developed method consists of two stages: (1) removing the tagging pattern based on analyzing and modeling the signal distribution in the image's k-space, and (2) enhancing the blood-myocardium contrast based on analyzing the signal intensity variability in the two tissues. The developed method is implemented on images from twelve human subjects. RESULTS: Ventricular mass measured with the developed method showed good agreement with that measured from gold-standard cMRI images. Further, preliminary results on measuring ventricular volume using the developed method are presented. CONCLUSION: The promising results in this study show the potential of the developed method for evaluating both regional and global heart function from a single set of tMRI images, with associated reduction in scan time and patient discomfort.


Assuntos
Cardiopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Análise de Componente Principal
3.
Artigo em Inglês | MEDLINE | ID: mdl-23367288

RESUMO

Age-related macular degeneration (AMD) is a major cause of blindness and visual impairment in older adults. The wet form of the disease is characterized by abnormal blood vessels forming a choroidal neovascular membrane (CNV), that result in destruction of normal architecture of the retina. Current evaluation and follow up of wet AMD include subjective evaluation of Fluorescein Angiograms (FA) to determine the activity of the lesion and monitor the progression or regression of the disease. However, this subjective evaluation prevents accurate monitoring of the disease progression or regression in response to a pharmacologic agent. In this work, we present a method that allows objective assessment of the activity of a CNV lesion which can be statistically compared across different patient and time points. The method is based on a hypothesis that the discrepancy in the time-intensity signals among the diseased and normal retinal areas are due to an implicit transfer function whose parameters can be used to characterize the retina. The method begins with parametric modeling of the temporal variation of the lesion and background intensities. Then, the values of the model parameters are used to evaluate the change in the activity of the disease. Preliminary results on five datasets show that the calculated parameters are highly correlated with the Visual Acuity (VA) of the patients.


Assuntos
Degeneração Macular/fisiopatologia , Modelos Estatísticos , Angiofluoresceinografia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA