Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Vasc Surg ; 75(1): 99-108.e2, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34425192

RESUMO

OBJECTIVE: A crucial step in designing fenestrated stent grafts for treatment of complex aortic abdominal aneurysms is the accurate positioning of the fenestrations. The deployment of a fenestrated stent graft prototype in a patient-specific rigid aortic model can be used for design verification in vitro, but is time and human resources consuming. Numerical simulation (NS) of fenestrated stent graft deployment using the finite element analysis has recently been developed; the aim of this study was to compare the accuracy of fenestration positioning by NS and in vitro. METHODS: All consecutive cases of complex aortic abdominal aneurysm treated with the Fenestrated Anaconda (Terumo Aortic) in six European centers were included in a prospective, observational study. To compare fenestration positioning, the distance from the center of the fenestration to the proximal end of the stent graft (L) and the angular distance from the 0° position (C) were measured and compared between in vitro testing (L1, C1) and NS (L2, C2). The primary hypothesis was that ΔL (|L2 - L1|) and ΔC (|C2 - C1|) would be 2.5 or less mm in more than 80% of the cases. The duration of both processes was also compared. RESULTS: Between May 2018 and January 2019, 50 patients with complex aortic abdominal aneurysms received a fenestrated stent graft with a total of 176 fenestrations. The ΔL and ΔC was 2.5 mm or less for 173 (98%) and 174 (99%) fenestrations, respectively. The NS process duration was significantly shorter than the in vitro (2.1 days [range, 1.0-5.2 days] vs 20.6 days [range, 9-82 days]; P < .001). CONCLUSIONS: Positioning of fenestrations using NS is as accurate as in vitro and could significantly decrease delivery time of fenestrated stent grafts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Modelos Cardiovasculares , Complicações Pós-Operatórias/epidemiologia , Stents/efeitos adversos , Aorta Abdominal/anatomia & histologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Simulação por Computador , Humanos , Modelos Anatômicos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
2.
Ann Vasc Surg ; 66: 160-170, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31978487

RESUMO

BACKGROUND: Although recent data on the treatment of thoracoabdominal aortic aneurysms (TAAAs) are promising, in some cases, the paravisceral segment of the aorta may not be suitable for a branched endograft due to space restrictions. A combination of a fenestrated aneurysm repair (FEVAR) with a thoracic aneurysm repair (TEVAR) may represent a feasible treatment option. The current investigation was performed to assess the stability of a fenestrated Anaconda device implanted into a set of thoracic endografts from different manufacturers. We then assessed our clinical results with the FEVAR/TEVAR combination. METHODS: Pull-out forces were measured in vitro after docking a fenestrated Anaconda graft within the distal end of different TEVAR devices. Anaconda devices were implanted in 28- or 30-mm thoracic tube grafts (oversizing of at least 2 mm: 13.3-21.4; minimum overlap of 15 mm). Continuously increasing longitudinal pull forces of up to 100 N were applied on an Instron Tensile Tester. Initial break point and damage to the endografts were documented. Clinical results of patients treated with such an FEVAR/TEVAR combination at our institution are presented as a second part of this study. RESULTS: Median pull-out forces ranged from 2.38 N to 55.0 N. The highest stability was achieved with 34-mm Anaconda devices in 28-mm thoracic tube grafts. Grafts with either thinner Dacron material or those featuring a polytetrafluorethylene membrane seemed especially vulnerable to punctures and tears caused by the downward-looking hooks of the Anaconda device. Between April 1, 2013 and December 31, 2018, in 28 of 172 patients treated with a fenestrated Anaconda device, prior implantation of a thoracic tube graft was necessary to create a sufficient proximal landing zone. In 25 cases (89.3%), the aneurysm was successfully treated. Although the 30-day reintervention rate in this subgroup was relatively high at 28.6%, none of these was due to a failure of the FEVAR/TEVAR combination. Upon an average follow-up of 15 months, no failure of the graft connection and no type III endoleak due to membrane damage were observed. CONCLUSIONS: The combination of a thoracic tube graft and a fenestrated Anaconda device is a viable option for the treatment of patients with Extent I or IV TAAAs with no adequate landing zone above the celiac trunk. Although pull-out testing has shown good stability with most assessed grafts, the thoracic devices with thicker Dacron membranes seemed to be especially suitable.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Feminino , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Polietilenotereftalatos , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Estresse Mecânico , Resistência à Tração , Resultado do Tratamento
3.
J Vasc Surg ; 68(2): 384-391, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29526378

RESUMO

OBJECTIVE: Because of its minimally invasive nature, percutaneous femoral access for endovascular aneurysm repair (pEVAR) is currently undergoing rapid popularization. Compared with surgical cutdown for femoral access (cEVAR), it offers the advantage of faster recovery after surgery as well as a reduction in wound complications. Despite proposed advantages, the method is largely considered uneconomical because of its reliance on costly closure devices. METHODS: There were 50 patients undergoing EVAR who were enrolled in this randomized prospective single-center trial. Each patient randomly received percutaneous access in one groin and surgical access in the other. The primary end points were access duration and cost. Secondary end points were wound complications and the postoperative pain levels. RESULTS: Surgery was performed per protocol in 44 patients. Mean access times for pEVAR and cEVAR were 11.5 ± 3.4 minutes and 24.8 ± 12.1 minutes (P < .001), respectively. Total access costs were €559.65 ± €112.69 for pEVAR and €674.85 ± €289.55 for cEVAR (P = .016). Eight complications in six patients were attributed to cutdown, none to pEVAR (P = .02). The percutaneously accessed groin was significantly less painful at day 1 and day 5 after surgery (P < .001). An intention-to-treat analysis (N = 50 patients) included six cases of pEVAR conversion due to technical failure in three patients (6%) and change of the operative strategy in another three patients (eg, aortouni-iliac stent graft followed by crossover bypass). The intention-to-treat analysis showed shorter mean overall access time for pEVAR (pEVAR, 14.65 ± 10.20 minutes; cEVAR, 25.12 ± 11.77 minutes; P < .001) and no cost difference between the two methods (pEVAR, €651.29 ± €313.49; cEVAR, €625.53 ± €238.29; P = .65). CONCLUSIONS: Our data confirm proposed potential benefits attributable to the minimally invasive nature of pEVAR while demonstrating cost-effectiveness despite the additional cost of closure devices. Taking into account pEVAR failures still does not increase pEVAR costs over cEVAR. Further considering reduced postoperative pain and wound complications, the technique deserves consideration in suitable patients.


Assuntos
Aneurisma/economia , Aneurisma/cirurgia , Implante de Prótese Vascular/economia , Cateterismo Periférico/economia , Procedimentos Endovasculares/economia , Artéria Femoral/cirurgia , Custos Hospitalares , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Áustria , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Redução de Custos , Análise Custo-Benefício , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Artéria Femoral/diagnóstico por imagem , Hematoma/economia , Hematoma/etiologia , Hematoma/terapia , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Dor Pós-Operatória/economia , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/terapia , Hemorragia Pós-Operatória/economia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Estudos Prospectivos , Punções , Instrumentos Cirúrgicos/economia , Fatores de Tempo , Resultado do Tratamento , Cicatrização
4.
Heart Rhythm ; 11(12): 2176-82, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25034184

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has become the standard therapy for high-risk and non-operable patients with severe aortic stenosis. However, the procedure involves several adverse effects, such as rhythm and conduction disturbances. Patients with postprocedural left bundle branch block may have an increased mortality risk, whereas patients with preprocedural right bundle branch block display a higher rate of postinterventional bradyarrhythmias. OBJECTIVE: The purpose of this study was to investigate the occurrence of high-degree atrioventricular block (AVB) in patients with preexisting bundle branch block (BBB) or BBB occurring during TAVI. METHODS: In this prospective single-center study, 50 consecutive patients undergoing TAVI with the Medtronic CoreValve Revalving System were included. Of these patients, 17 with preexisting BBB or BBB occurring during TAVI received a primary prophylactic permanent DDD pacemaker, programmed to the SafeR-mode and featuring dual-channel event counters as well as stored intracardiac electrograms. Pacemaker readouts and intracardiac electrograms were analyzed for the occurrence of high-degree AVB. RESULTS: Ten of 17 patients (58.8%) with preexisting BBB or BBB occurring during TAVI developed episodes of high-degree AVB that were immediately terminated due to switch into DDD backup pacing. In 5 of the cases (29.4%), the first documented episode of high-degree AVB occurred after hospital discharge. Mean follow-up period was 578.1 ± 294.9 days. CONCLUSION: Development of high-degree AVB is a common complication in patients with preexisting BBB or BBB occurring during TAVI. Accordingly, intensified monitoring might be reasonable, especially in patients treated with the self-expandable Medtronic CoreValve Revalving System.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/epidemiologia , Bloqueio de Ramo/epidemiologia , Complicações Intraoperatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Animais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estudos de Coortes , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Incidência , Complicações Intraoperatórias/diagnóstico , Masculino , Marca-Passo Artificial , Cobertura de Condição Pré-Existente , Estudos Prospectivos , Índice de Gravidade de Doença , Distribuição por Sexo , Estatísticas não Paramétricas , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA