Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Vasc Surg ; 74(3): 861-870, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33775747

RESUMO

OBJECTIVE: Fenestrated-branched endovascular aneurysm repair (FBEVAR) has expanded the treatment of patients with thoracoabdominal aortic aneurysms (TAAAs). Previous studies have demonstrated that women are less likely to be treated with standard infrarenal endovascular aneurysm repair because of anatomic ineligibility and experience greater mortality after both infrarenal and thoracic aortic aneurysm repair. The purpose of the present study was to describe the sex-related outcomes after FBEVAR for treatment of TAAAs. METHODS: The data from 886 patients with extent I to IV TAAAs (excluding pararenal or juxtarenal aneurysms), enrolled in eight prospective, physician-sponsored, investigational device exemption studies from 2013 to 2019, were analyzed. All data were collected prospectively, audited and adjudicated by clinical events committees and/or data safety monitoring boards, and subject to Food and Drug Administration oversight. All the patients had been treated with Cook-manufactured patient-specific FBEVAR devices or the Cook t-Branch off-the-shelf device (Cook Medical, Brisbane, Australia). RESULTS: Of the 886 patients who underwent FBEVAR, 288 (33%) were women. The women had more extensive aneurysms and a greater prevalence of diabetes (33% vs 26%; P = .043) but a lower prevalence of coronary artery disease (33% vs 52%; P < .0001) and previous infrarenal endovascular aneurysm repair (7.6% vs 16%; P < .001). The women had required a longer operative time from incision to surgery end (5.0 ± 1.8 hours vs 4.6 ± 1.7 hours; P < .001), experienced lower technical success (93% vs 98%; P = .002), and were less likely to be discharged to home (72% vs 83%; P = .009). Despite the smaller access vessels, the women did not have an increased incidence of access site complications. Also, the 30-day outcomes were broadly similar between the sexes. At 1 year, no differences were found between the women and men in freedom from type I or III endoleak (91.4% vs 92.0%; P = .64), freedom from reintervention (81.7% vs 85.3%; P = .10), target vessel instability (87.5% vs 89.2%; P = .31), and survival (89.6% vs 91.7%; P = .26). The women had a greater incidence of postoperative sac expansion (12% vs 6.5%; P = .006). Multivariable modeling adjusted for age, aneurysm extent, aneurysm size, urgent procedure, and renal function showed that patient sex was not an independent predictor of survival (hazard ratio, 0.83; 95% confidence interval, 0.50-1.37; P = .46). CONCLUSIONS: Women undergoing FBEVAR demonstrated metrics of increased complexity and had a lower level of technical success, especially those with extensive aneurysms. Compared with the men, the women had similar 30-day mortality and 1-year outcomes, with the exception of an increased incidence of sac expansion. These data have demonstrated that FBEVAR is safe and effective for women and men but that further efforts to improve outcome parity are indicated.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Comorbidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
2.
J Vasc Surg ; 73(6): 2144-2153, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33359847

RESUMO

BACKGROUND: Surgical procedures account for 50% of hospital revenue and ∼60% of operating costs. On average, <20% of surgical instruments will be used during a case, and the expense for resterilization and assembly of instrument trays ranges from $0.51 to $3.01 per instrument. Given the complexity of the surgical service supply chain, physician preferences, and variation of procedures, a reduction of surgical cost has been extremely difficult and often ill-defined. A data-driven approach to instrument tray optimization has implications for efficiency and cost savings in sterile processing, including reductions in tray assembly time and instrument repurchase, repair, and avoidable depreciation. METHODS: During a 3-month period, vascular surgery cases were monitored using a cloud-based technology product (OpFlow, Operative Flow Technologies, Raleigh, NC) as a part of a hospital-wide project. Given the diversity of the cases evaluated, we focused on two main vascular surgery trays: vascular and aortic. An assessment was performed to evaluate the exact instruments used by the operating surgeons across a variety of cases. The vascular tray contained 131 instruments and was used for the vast majority of vascular cases, and the aortic tray contained 152 instruments. Actual instrument usage data were collected, a review and analysis performed, and the trays optimized. RESULTS: During the 3-month period, 168 vascular surgery cases were evaluated across six surgeons. On average, the instrument usage per tray was 30 of 131 instruments (22.9%) for the vascular tray and 19 of 152 (12.5%) for the aortic tray. After review, 45.8% of the instruments were removed from the vascular tray and 62.5% from the aortic tray, for 1255 instruments removed from the versions of both trays. An audit was performed after the removal of instruments, which showed that none of the removed instruments had required reinstatement. The instrument reduction from these two trays alone yielded an estimated costs savings of $97,781 for repurchase and $97,444 in annual resterilization savings. Annually, the removal of the instruments is projected to save 316.2 hours of personnel time. The time required for operating room table setup decreased from a mean of 7:44 to 5:02 minutes for the vascular tray (P < .0001) and from 8:53 to 4:56 minutes for the aortic tray (P < .0001). CONCLUSIONS: Given increasing cost constraints in healthcare, sterile processing remains an untapped resource for surgical expense reduction. A comprehensive data analytics solution provided the ability to make informed decisions in tray management that otherwise could not be reliably performed.


Assuntos
Custos Hospitalares , Salas Cirúrgicas/economia , Instrumentos Cirúrgicos/economia , Procedimentos Cirúrgicos Vasculares/economia , Procedimentos Cirúrgicos Vasculares/instrumentação , Computação em Nuvem , Redução de Custos , Análise Custo-Benefício , Reutilização de Equipamento/economia , Humanos , Aprendizado de Máquina , Projetos Piloto , Esterilização/economia , Fatores de Tempo , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA