Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Invasive Cardiol ; 36(1)2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38224295

RESUMO

OBJECTIVES: Ostial CTOs can be challenging to revascularize. We aim to describe the outcomes of ostial chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We examined the clinical and angiographic characteristics and procedural outcomes of 8788 CTO PCIs performed at 35 US and non-US centers between 2012 and 2022. In-hospital major adverse cardiac events (MACE) included death, myocardial infarction, urgent repeat target-vessel revascularization, tamponade requiring pericardiocentesis or surgery, and stroke. RESULTS: Ostial CTOs constituted 12% of all CTOs. Patients with ostial CTOs had higher J-CTO score (2.9 ± 1.2 vs 2.3 ± 1.3; P less than .01). Ostial CTO PCI had lower technical (82% vs. 86%; P less than .01) and procedural (81% vs. 85%; P less than .01) success rates compared with non-ostial CTO PCI. Ostial location was not independently associated with technical success (OR 1.03, CI 95% 0.83-1.29 P =.73). Ostial CTO PCI had a trend towards higher incidence of MACE (2.6% vs. 1.8%; P =.06), driven by higher incidence of in-hospital death (0.9% vs 0.3% P less than.01) and stroke (0.5% vs 0.1% P less than .01). Ostial lesions required more often use of the retrograde approach (30% vs 9%; P less than .01). Ostial CTO PCI required longer procedure time (149 [103,204] vs 110 [72,160] min; P less than .01) and higher air kerma radiation dose (2.3 [1.3, 3.6] vs 2.0 [1.1, 3.5] Gray; P less than .01). CONCLUSIONS: Ostial CTOs are associated with higher lesion complexity and lower technical and procedural success rates. CTO PCI of ostial lesions is associated with frequent need for retrograde crossing, higher incidence of death and stroke, longer procedure time and higher radiation dose.


Assuntos
Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Humanos , Mortalidade Hospitalar , Intervenção Coronária Percutânea/efeitos adversos , Ecocardiografia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Hemodinâmica
2.
Cardiol J ; 29(2): 245-251, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34708864

RESUMO

BACKGROUND: The treatment of choice for severe rheumatic mitral stenosis (MS) is balloon mitral valvuloplasty (BMV). Assessment of MS severity is usually performed by echocardiography. Before performing BMV, invasive hemodynamic assessment is also performed. The effect of anesthesia on the invasive assessment of MS severity has not been studied. The purpose of the present study was to assess changes in invasive hemodynamic measurement of MS severity before and after induction of general anesthesia. METHODS: The medical files of 22 patients who underwent BMV between 2014 and 2020 were reviewed. Medical history, laboratory, echocardiographic and invasive measurements were collected. Anesthesia induction was performed with etomidate or propofol. Pre-procedural echocardiographic measurements of valve area using pressure half time, and continuity correlated well with invasive measurements using the Gorlin formula. RESULTS: After induction of anesthesia the mean mitral valve gradient dropped by 2.4 mmHg (p = 0.153) and calculated mitral valve area (MVA) increased by 0.2 cm2 (p = 0.011). A wide variability in individual response was observed. While a drop in gradient was noted in 14 patients, it increased in 7. Gorlin derived MVA rose in most patients but dropped in 4. Assuming a calculated MVA of 1.5 cm2 and below to define clinically significant MS, 4 patients with pre-induction MVA of 1.5 cm2 or below had calculated MVA above 1.5 cm2 after induction. CONCLUSIONS: The impact of general anesthesia on the hemodynamic assessment of MS is heterogeneous and may lead to misclassification of MS severity.


Assuntos
Anestesia , Valvuloplastia com Balão , Estenose da Valva Mitral , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico
3.
Cardiology ; 138(3): 195-199, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28793300

RESUMO

OBJECTIVES: During the past decade, the most common causes of mortality and morbidity were cardiovascular diseases and malignancies. The aim of the current study was to describe the incidence, course of admission, and short-term (30-day) prognosis of patients with and without malignancy, admitted to a tertiary center intensive cardiovascular care unit (ICCU). METHODS: A prospective observational study of 2,259 patients admitted to the ICCU was conducted between January 2014 and December 2015. Patients with malignancies (n = 256) were divided into 2 groups: those with solid and those with homogenous tumors. RESULTS: The time of diagnosis was categorized into 3 patient groups: recent (<6 months), 59 patients (23%); late (6-24 months), 49 patients (19%), and very late (>24 months), 148 patients (58%). Those with a history of malignancy were older (73 ± 12 vs. 64 ± 15, p < 0.001) and were more likely to be female (p = 0.002). After using a multivariate logistic regression model analysis, no differences were found in therapeutic interventions and clinical outcomes, including major bleeding and acute renal failure, between patients with and without malignancies. CONCLUSIONS: Patients with a malignancy comprised about 10% of the entire ICCU population. While mortality was independently associated with advanced age, renal failure, and a diagnosis of ST-elevation myocardial infarction, malignancy alone was not found to be independently associated with a higher mortality rate at 30 days of follow-up.


Assuntos
Hospitalização/estatística & dados numéricos , Unidades de Terapia Intensiva/estatística & dados numéricos , Neoplasias/complicações , Neoplasias/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Efeitos Psicossociais da Doença , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Israel/epidemiologia , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Centros de Atenção Terciária , Fatores de Tempo
4.
Int J Cardiol ; 215: 227-31, 2016 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27128536

RESUMO

BACKGROUND: Accurate risk stratification is pivotal for appropriate selection of patients with severe symptomatic aortic stenosis for either surgical or transcatheter aortic valve replacement (TAVR). We sought to determine whether recent risk prediction models developed specifically in TAVR patients enhance prognostication in comparison with previous surgical scores used in clinical practice (EuroScore I, EuroScore II, STS). METHODS: The Israeli TAVR Registry Risk Model Accuracy Assessment (IRRMA) study utilized a multicenter prospective TAVR database (n=1327) to perform a quantitative comparison between previous risk scores developed in either surgical or TAVR populations, with the present registry serving as an independent external validation set. RESULTS: In the IRRMA population, 4 variables (NYHA functional class IV, chronic obstructive pulmonary disease, systolic pulmonary artery pressure ≥60mmHg, vascular access other than by the femoral route) identified by cross-validation and leave-one-out analyses provided the most discriminative model (C-statistic=0.63) for predicting 30-day mortality. Previous scores developed in surgical (EuroScores I and II, STS), TAVR (FRANCE-2, OBSERVANT), or mixed (German AV score) populations were applied to the IRRMA cohort. Resultant C-statistics ranged between 0.52-0.71 (for the German AV and FRANCE-2 scores, respectively) and did not differ significantly (p=0.07 for the comparison between the lowest and highest C-statistics). The observed C-statistic for 5 of these 6 scores was lower than originally reported when applied to the IRRMA population. CONCLUSION: Available TAVR risk scores showed limited accuracy when applied to an independent validation set and did not enhance prognostication in comparison to previous surgical scores.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Israel , Masculino , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA