Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Res Cardiol ; 109(3): 271-288, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31482241

RESUMO

According to recent recommendations on echocardiographic assessment of aortic valve stenosis direct measurement of transvalvular peak jet velocity, calculation of transvalvular mean gradient from the velocities using the Bernoulli equation and calculation of the effective aortic valve area by continuity equation are the appropriate primary key instruments for grading severity of aortic valve stenosis. It is obvious that no gold standard can be declared for grading the severity of aortic stenosis. Thus, conclusions of the exclusive evaluation of aortic stenosis by Doppler echocardiography seem to be questionable due to the susceptibility to errors caused by methodological limitations, mathematical simplifications and inappropriate documentation. The present paper will address practical issues of echocardiographic documentation to satisfy the needs to analyze different scenarios of aortic stenosis due to various flow conditions and pressure gradients. Transesophageal and multidimensional echocardiography should be implemented for reliable measurement of geometric aortic valve area and of cardiac dimensions at an early stage of the diagnostic procedure to avoid misinterpretation due to inconsistent results.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Erros Médicos/prevenção & controle , Estenose da Valva Aórtica/fisiopatologia , Documentação , Ecocardiografia Doppler/métodos , Humanos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
2.
JACC Cardiovasc Imaging ; 12(11 Pt 1): 2225-2244, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30878428

RESUMO

Reconstructive surgery of the aortic valve is being increasingly used in patients with aortic regurgitation and/or aortic aneurysm. Its success depends on restoring normal aortic valve and root form. Echocardiography is the most reliable and precise imaging technique because it defines abnormal morphology and function, essential for selecting appropriate substrates and guiding the surgical strategy. Despite technical advances in echocardiography, aortic valve and aortic root morphology and function are still assessed mainly using 2-dimensional echocardiography in clinical practice. This review focuses on the need to use 3-dimensional echocardiography to characterize different forms of aortic valve and root abnormalities and attempts to define echocardiographic predictors of successful valve-root complex repair.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Aneurisma Aórtico/fisiopatologia , Aneurisma Aórtico/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Procedimentos de Cirurgia Plástica , Recuperação de Função Fisiológica , Resultado do Tratamento
3.
Int J Cardiovasc Imaging ; 35(5): 881-895, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30701439

RESUMO

The assessment of aortic valve (AV) morphology is paramount for planning transcatheter AV implantation (TAVI). Nowadays, pre-TAVI sizing is routinely performed at one cardiac phase only, usually at mid-systole. Nonetheless, the AV is a dynamic structure that undergoes changes in size and shape throughout the cardiac cycle, which may be relevant for prosthesis selection. Thus, the aim of this study was to present and evaluate a novel software tool enabling the automatic sizing of the AV dynamically in three-dimensional (3D) transesophageal echocardiography (TEE) images. Forty-two patients who underwent preoperative 3D-TEE images were retrospectively analyzed using the software. Dynamic measurements were automatically extracted at four levels, including the aortic annulus. These measures were used to assess the software's ability to accurately and reproducibly quantify the conformational changes of the aortic root and were validated against automated sizing measurements independently extracted at distinct time points. The software extracted physiological dynamic measurements in less than 2 min, that were shown to be accurate (error 2.2 ± 26.3 mm2 and 0.0 ± 2.53 mm for annular area and perimeter, respectively) and highly reproducible (0.85 ± 6.18 and 0.65 ± 7.90 mm2 of intra- and interobserver variability, respectively, in annular area). Using the maximum or minimum measured values rather than mid-systolic ones for device sizing resulted in a potential change of recommended size in 7% and 60% of the cases, respectively. The presented software tool allows a fast, automatic and reproducible dynamic assessment of the AV morphology from 3D-TEE images, with the extracted measures influencing the device selection depending on the cardiac moment used to perform its sizing. This novel tool may thus ease and potentially increase the observer's confidence during prosthesis' size selection at the preoperative TAVI planning.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Hemodinâmica , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Automação , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Design de Software , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação
4.
Eur Heart J Cardiovasc Imaging ; 20(1): 66-74, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29481687

RESUMO

Aim: To determine if incorporation of assessment of mechanical dyssynchrony could improve the prognostic value of patient selection based on current guidelines. Methods and results: Echocardiography was performed in 1060 patients before and 12 ± 6 months after cardiac resynchronization therapy (CRT) implantation. Mechanical dyssynchrony, defined as the presence of apical rocking or septal flash was visually assessed at the baseline examination. Response was defined as ≥15% reduction in left ventricular end-systolic volume at follow-up. Patients were followed for a median of 59 months (interquartile range 37-86 months) for the occurrence of death of any cause. Applying the latest European guidelines retrospectively, 63.4% of the patients had been implanted with a Class I recommendation, 18.2% with Class IIa, 9.4% with Class IIb, and in 9% no clear therapy recommendation was present. Response rates were 65% in Class I, 50% in IIa, 38% in IIb patients, and 40% in patients without a clear guideline-based recommendation. Assessment of mechanical dyssynchrony improved response rates to 77% in Class I, 75% in IIa, 62% in IIb, and 69% in patients without a guideline-based recommendation. Non-significant difference in survival among guideline recommendation classes was found (Log-rank P = 0.2). Presence of mechanical dyssynchrony predicted long-term outcome better than guideline Classes I, IIa, IIb (Log-rank P < 0.0001, 0.006, 0.004, respectively) and in patients with no guideline recommendation (P = 0.02). Comparable results were observed using the latest American Guidelines. Conclusion: Our data suggest that current guideline criteria for CRT candidate selection could be improved by incorporating assessment of mechanical asynchrony.


Assuntos
Terapia de Ressincronização Cardíaca , Fidelidade a Diretrizes , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Seleção de Pacientes , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento
5.
J Am Soc Echocardiogr ; 23(3): 258-64, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20138473

RESUMO

BACKGROUND: The purpose of this multicenter study was to determine the reliability of visual assessments of segmental wall motion (WM) abnormalities and global left ventricular function among highly experienced echocardiographers using contemporary echocardiographic technology in patients with a variety of cardiac conditions. METHODS: The reliability of visual determinations of left ventricular WM and global function was calculated from assessments made by 12 experienced echocardiographers on 105 echocardiograms recorded using contemporary echocardiographic equipment. Ten studies were reread independently to determine intraobserver reliability. RESULTS: Interobserver reliability for visual differentiation between normal, hypokinetic, and akinetic segments had an intraclass correlation coefficient of 0.70. The intraclass correlation coefficient for dichotomizing segments into normal versus other abnormal was 0.63, for hypokinetic versus other scores was 0.26, and for akinetic versus other scores was 0.58. Similar results were found for intraobserver reliability. Interobserver reliability for WM score index was 0.84 and for left ventricular ejection fraction was 0.78. Similar values were obtained for the intraobserver reliability of WM score index and ejection fraction. Compared to angiographic data, the accuracy of segmental WM assessments was 85%, and correct determination of the culprit artery was achieved in 59% of patients with myocardial infarctions. CONCLUSION: Among experienced readers using contemporary echocardiographic equipment, interobserver and intraobserver reliability was reasonable for the visual quantification of normal and akinetic segments but poor for hypokinetic segments. Reliability was good for the visual assessment of global left ventricular function by WM score index and ejection fraction.


Assuntos
Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Feminino , Humanos , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
6.
Circ Cardiovasc Imaging ; 3(1): 47-53, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19926829

RESUMO

BACKGROUND: Identification and quantification of segmental left ventricular wall motion abnormalities on echocardiograms is of paramount clinical importance but is still performed by a subjective visual method. We constructed an automatic tool for assessment of wall motion based on longitudinal strain. METHODS AND RESULTS: Echocardiograms of 105 patients (3 apical views) were blindly analyzed by 12 experienced readers. Visual segmental scores (VSS) and peak systolic longitudinal strain were assigned to each of 18 segments per patient. Ranges of peak systolic longitudinal strain that best fit VSS (by receiver operating characteristic analysis) were used to generate automatic segmental scores (ASS). Comparisons of ASS and VSS were performed on 1952 analyzable segments. There was agreement of wall motion scores between both methods in 89.6% of normal, 39.5% of hypokinetic, and 69.4% of akinetic segments. Correlation between methods was r=0.63 (P<0.0001). Interobserver and intraobserver reliability using interclass correlation for scoring segmental wall motion into 3 scores by ASS was 0.82 and 0.83 and by VSS 0.70 and 0.69, respectively. Compared with VSS (majority rule), ASS had a sensitivity, specificity, and accuracy of 87%, 85%, and 86%, respectively. ASS and VSS had similar success rates for correct identification of wall motion abnormalities in territories supplied by culprit arteries. VSS had greater specificity and positive predictive values, whereas ASS had higher sensitivity and negative predictive values for identifying the culprit artery. CONCLUSIONS: Automatic quantification of wall motion on echocardiograms by this tool performs as well as visual analysis by experienced echocardiographers, with a greater reliability and similar agreement to angiographic findings.


Assuntos
Automação , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Contração Miocárdica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Angiografia Coronária , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Ultrassonografia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA