RESUMO
PURPOSE: To assess ciliary muscle (CM) and anterior scleral thickness (AST) dimensions in vivo in high myopia using swept-source optical coherence tomography (SS-OCT) and to compare with emmetropic and hyperopic subjects. METHODS: Cross-sectional study that included 34 high myopic patients (≥ -6 diopters [D]), 90 emmetropes (-1 to +1 D) and 38 hyperopic patients (≥ +3.5 D). CM thickness (CMT) and AST were measured in the temporal and nasal quadrants at 1, 2, and 3 mm from the scleral spur using SS-OCT. In addition, the length of the CM (CML) was evaluated. RESULTS: The dimensions of the CML and the CMT at any of their measurement points were greater in high myopes and emmetropes than in hyperopes, both in the nasal and temporal quadrants (P < .001). However, there were no differences between high myopes and emmetropes for any of the parameters (P ≥ .076) except for the CMT at 3 mm in the temporal quadrant (P < .001). There were no differences in the AST between high myopes, emmetropes and hyperopes, in any of the measurement points or quadrants studied (P > .05). CONCLUSIONS: The SS-OCT allows to measure the CM in vivo, not observing differences in its dimensions between high myopes and emmetropes, but they were smaller in hyperopes. In the measurement of the anterior sclera, no differences were observed between the three groups analyzed according to refraction.
Assuntos
Hiperopia , Miopia , Humanos , Tomografia de Coerência Óptica/métodos , Esclera/diagnóstico por imagem , Estudos Transversais , Miopia/diagnóstico por imagem , MúsculosRESUMO
PURPOSE: To analyze the agreement between Pentacam and optical coherence tomography (OCT) in the assessment of trabecular-iris angle (TIA) width in a large population of normal subjects. METHODS: A cross-sectional study was performed in 989 right eyes of 989 healthy subjects. The trabecular-iris angle (TIA) was measured in the temporal and nasal quadrants using the Pentacam (Oculus, Wetzlar, Germany), a device based on Scheimpflug technology and RTVue 100 OCT (Optovue, Fremont, CA, USA). Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to evaluate agreement between these devices. RESULTS: Mean age was 49.1±15.2 years (18-84); 61% were women and spherical error range was -14 to 8.25. TIA could be measured by OCT in 94.9% and 94.1% in the temporal and nasal quadrants, with a mean value of 35.8±13.2 degrees (2.5-78.7) and 35.7±12.9 degrees (2.2-76.8) respectively. TIA was able to be measured by Pentacam in 95.2% and 95% in the temporal and nasal quadrants and means were 35.7±7.3 degrees (11-74.2) and 36.4±8.2 degrees (14.5-64) respectively. An ICC of 0.378 (95% confidence interval [CI], 0.322-0.431) and 0.589 (95% CI 0.546-0.629) for the temporal and nasal quadrants was obtained, showing moderate agreement between the devices. Bland-Altman plots revealed that, compared with OCT, Pentacam tends to overestimate measurements in narrow angles and underestimate these in open angles. CONCLUSIONS: Agreement between OCT and Pentacam was mediocre, indicating the two devices are not interchangeable when used to measure angle width.