Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
Sleep ; 37(12): 1953-61, 2014 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25325484

RESUMO

INTRODUCTION: Home single-channel nasal pressure (HNP) may be an alternative to polysomnography (PSG) for obstructive sleep apnea (OSA) diagnosis, but no cost studies have yet been carried out. Automatic scoring is simpler but generally less effective than manual scoring. OBJECTIVES: To determine the diagnostic efficacy and cost of both scorings (automatic and manual) compared with PSG, taking as a polysomnographic OSA diagnosis several apnea-hypopnea index (AHI) cutoff points. METHODS: We included suspected OSA patients in a multicenter study. They were randomized to home and hospital protocols. We constructed receiver operating characteristic (ROC) curves for both scorings. Diagnostic efficacy was explored for several HNP AHI cutoff points, and costs were calculated for equally effective alternatives. RESULTS: Of 787 randomized patients, 752 underwent HNP. Manual scoring produced better ROC curves than automatic for AHI < 15; similar curves were obtained for AHI ≥ 15. A valid HNP with manual scoring would determine the presence of OSA (or otherwise) in 90% of patients with a polysomnographic AHI ≥ 5 cutoff point, in 74% of patients with a polysomnographic AHI ≥ 10 cutoff point, and in 61% of patients with a polysomnographic AHI ≥ 15 cutoff point. In the same way, a valid HNP with automatic scoring would determine the presence of OSA (or otherwise) in 73% of patients with a polysomnographic AHI ≥ 5 cutoff point, in 64% of patients with a polysomnographic AHI ≥ 10 cutoff point, and in 57% of patients with a polysomnographic AHI ≥ 15 cutoff point. The costs of either HNP approaches were 40% to 70% lower than those of PSG at the same level of diagnostic efficacy. Manual HNP had the lowest cost for low polysomnographic AHI levels (≥ 5 and ≥ 10), and manual and automatic scorings had similar costs for higher polysomnographic cutoff points (AHI ≥ 15) of diagnosis. CONCLUSION: Home single-channel nasal pressure (HNP) is a cheaper alternative than polysomnography for obstructive sleep apnea diagnosis. HNP with manual scoring seems to have better diagnostic accuracy and a lower cost than automatic scoring for patients with low apnea-hypopnea index (AHI) levels, although automatic scoring has similar diagnostic accuracy and cost as manual scoring for intermediate and high AHI levels. Therefore, automatic scoring can be appropriately used, although diagnostic efficacy could improve if we carried out manual scoring on patients with AHI < 15. CLINICAL TRIALS INFORMATION: Clinicaltrials.gov identifier: NCT01347398.


Assuntos
Custos e Análise de Custo , Nariz/fisiologia , Pressão , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/economia , Curva ROC , Apneia Obstrutiva do Sono/economia , Adulto Jovem
3.
J Hazard Mater ; 101(3): 315-22, 2003 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-12935762

RESUMO

The pre-oxidation of an extremely polluted pharmaceutical wastewater (chemical oxygen demand (COD) value of 362,000mg/l) using the Fenton's reagent has been systematically studied using an experimental design technique. The parameters influencing the COD removal of the wastewater, namely temperature, ferrous ion and hydrogen peroxide concentrations have been optimized to achieve a COD global reduction of 56.4%. The total range of the proposed experimental design, however, could not be tested because under some conditions (hydrogen peroxide concentration over 5M) the Fenton's reaction became violent and could not be controlled, probably due to the high exothermic effect associated with COD oxidation. For the tested conditions, the optimal values of hydrogen peroxide and ferrous ion concentration were 3 and 0.3M, respectively, whereas temperature only showed a mild positive effect on COD removal. In addition, during the first 10min of Fenton's reaction, more than 90% of the total COD removal can be achieved.Fenton's reaction has proved to be a feasible technique for the pre-oxidation of the wastewater under study, and can be considered a suitable pre-treatment for this type of wastewaters.


Assuntos
Indústria Farmacêutica , Peróxido de Hidrogênio/química , Ferro/química , Oxidantes/química , Poluentes Químicos da Água/análise , Resíduos Industriais , Oxirredução , Oxigênio/análise , Purificação da Água/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA