1.
Radiat Prot Dosimetry ; 180(1-4): 201-205, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29069460

RESUMO

Fluorescent nuclear track detectors (FNTDs) as criticality dosimeters for both neutrons and gamma are further characterized in terms of angular dependence and quick dose assessment. The power spectrum integral depth profiles obtained from stacks of fluorescent images acquired within FNTDs exposed to a broad spectrum neutron field at various angles are analyzed to determine a calibration curve for angular dependence. MCNPX simulations were shown to be in good agreement with experimental results. A prototype triage reader was also designed and tested for quick assessment of dose. An unfolding technique incorporating both energy dependence and angular dependence is discussed. The advantages and shortcomings of using FNTDs in the event of a criticality excursion accident are analyzed.


Assuntos
Nêutrons , Reatores Nucleares , Dosímetros de Radiação , Radiometria/instrumentação , Algoritmos , Calibragem , Simulação por Computador , Relação Dose-Resposta à Radiação , Nêutrons Rápidos , Raios gama , Método de Monte Carlo , Fótons , Liberação Nociva de Radioativos , Reprodutibilidade dos Testes
2.
Radiat Prot Dosimetry ; 180(1-4): 215-219, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29077974

RESUMO

The neutron-energy dependence of the track-counting sensitivity of fluorescent nuclear track detectors (FNTDs) at two ranges of Mg doping, resulting in different crystal colorations, was investigated. The performance of FNTDs was studied with the following converters: Li-glass for thermal to intermediate-energy neutrons, polyethylene for fast neutrons, and polytetrafluoroethylene (Teflon™) for photon- and radon-background subtraction. The irradiations with monoenergetic neutrons were performed at the National Physics Laboratory (NPL), UK. The energy range was varied from 144 keV to 16.5 MeV in the personal dose equivalent range from 1 to 3 mSv. Monte Carlo simulations were performed to model the response of FNTDs to monoenergetic neutrons. A good agreement with the experimental data was observed suggesting the development of a basic model for future MC studies. Further work will focus on increasing FNTD sensitivity to low-energy neutrons and developing a faster imaging technique for scanning larger areas to improve counting statistics.


Assuntos
Nêutrons , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/instrumentação , Artefatos , Desenho de Equipamento , Nêutrons Rápidos , Processamento de Imagem Assistida por Computador , Transferência Linear de Energia , Método de Monte Carlo , Óptica e Fotônica , Fótons , Polietileno/química , Politetrafluoretileno/química , Sensibilidade e Especificidade , Reino Unido
3.
Vestn Khir Im I I Grek ; 163(1): 93-6, 2004.
Artigo em Russo | MEDLINE | ID: mdl-15143595

RESUMO

A comparative analysis of long-term results of reconstructive operations on the femoro-popliteal segment performed by different techniques was based on the assessment of the operation results made by the patients and their social rehabilitation after the operation. The operations of choice may be thought to be reconstruction with the application of transplants of velours dacron with a gelatin impregnation (VDGI), polytetraftoroethylene (PTFE) and autovein. Transplants of VDGI are found to be preferable. The long-term results of using PTFE transplants in the femoro-popliteal position were shown by the authors to be inferior to VDGI transplants. Since PTFE is much more expensive than dacron, the practice of so wide using this material should be revised. The authors believe that endarterectomy can not be considered to be the operation of choice for long-standing occlusions of the superficial femoral artery. They should be used but for critical ischemia of the extremity when trying to safe it if the transplants of VDGI and PTFE and good autovein are not available. The long-term results of using lavsan-ftorolon transplants in the femoro-popliteal position suggest that they should not be used in practice.


Assuntos
Arteriopatias Oclusivas/cirurgia , Artéria Femoral/cirurgia , Doenças Vasculares Periféricas/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Artéria Poplítea/cirurgia , Cuidados Pós-Operatórios , Autoavaliação (Psicologia) , Humanos
SELEÇÃO DE REFERÊNCIAS