Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Am J Surg ; 215(1): 19-22, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28676153

RESUMO

BACKGROUND: Average costs associated with common procedures can vary by surgeon without a corresponding variation in outcome or case complexity. METHODS: De-identified cost and equipment utilization data were collected from our hospital for elective laparoscopic cholecystectomy performed by 17 different surgeons over a 6-month period. A group of surgeons used this data to design a standardized equipment pick list that became optional (not mandated) for laparoscopic cholecystectomy. Cost and consumable surgical supply utilization data were collected for six months prior to and following the creation of the standardized pick-list. RESULTS: 280 elective laparoscopic cholecystectomies were performed during the study interval. In the 6 months after standardized pick list creation, the cost of disposable supplies utilized per case decreased by 32%. CONCLUSIONS: Surgical cost savings can be achieved with standardized procedure pick lists and attention to the cost of consumable surgical supplies.


Assuntos
Colecistectomia Laparoscópica/economia , Redução de Custos/estatística & dados numéricos , Equipamentos Descartáveis/economia , Procedimentos Cirúrgicos Eletivos/economia , Fidelidade a Diretrizes/economia , Custos Hospitalares/estatística & dados numéricos , Padrões de Prática Médica/economia , Colecistectomia Laparoscópica/instrumentação , Colecistectomia Laparoscópica/normas , Colecistectomia Laparoscópica/estatística & dados numéricos , Equipamentos Descartáveis/normas , Equipamentos Descartáveis/estatística & dados numéricos , Procedimentos Cirúrgicos Eletivos/instrumentação , Procedimentos Cirúrgicos Eletivos/normas , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Fidelidade a Diretrizes/estatística & dados numéricos , Humanos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas , Padrões de Prática Médica/estatística & dados numéricos , Estudos Retrospectivos , Wisconsin
2.
Surg Endosc ; 31(1): 185-192, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27139704

RESUMO

BACKGROUND: Robotic surgical systems have been used at a rapidly increasing rate in general surgery. Many of these procedures have been performed laparoscopically for years. In a surgical encounter, a significant portion of the total costs is associated with consumable supplies. Our hospital system has invested in a software program that can track the costs of consumable surgical supplies. We sought to determine the differences in cost of consumables with elective laparoscopic and robotic procedures for our health care organization. METHODS: De-identified procedural cost and equipment utilization data were collected from the Surgical Profitability Compass Procedure Cost Manager System (The Advisory Board Company, Washington, DC) for our health care system for laparoscopic and robotic cholecystectomy, fundoplication, and inguinal hernia between the years 2013 and 2015. Outcomes were length of stay, case duration, and supply cost. Statistical analysis was performed using a t-test for continuous variables, and statistical significance was defined as p < 0.05. RESULTS: The total cost of consumable surgical supplies was significantly greater for all robotic procedures. Length of stay did not differ for fundoplication or cholecystectomy. Length of stay was greater for robotic inguinal hernia repair. Case duration was similar for cholecystectomy (84.3 robotic and 75.5 min laparoscopic, p = 0.08), but significantly longer for robotic fundoplication (197.2 robotic and 162.1 min laparoscopic, p = 0.01) and inguinal hernia repair (124.0 robotic and 84.4 min laparoscopic, p = â‰ª0.01). CONCLUSIONS: We found a significantly increased cost of general surgery procedures for our health care system when cases commonly performed laparoscopically are instead performed robotically. Our analysis is limited by the fact that we only included costs associated with consumable surgical supplies. The initial acquisition cost (over $1 million for robotic surgical system), depreciation, and service contract for the robotic and laparoscopic systems were not included in this analysis.


Assuntos
Colecistectomia/economia , Fundoplicatura/economia , Hérnia Inguinal/economia , Laparoscopia/economia , Procedimentos Cirúrgicos Robóticos/economia , Colecistectomia/métodos , Custos e Análise de Custo , Hérnia Inguinal/cirurgia , Humanos , Tempo de Internação , Duração da Cirurgia , Wisconsin
3.
Surg Laparosc Endosc Percutan Tech ; 26(2): 137-40, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26766323

RESUMO

We sought to characterize the changes in esophagogastric junction (EGJ) distensibility during Heller Myotomy with Dor fundoplication using the EndoFLIP device. Intraoperative distensibility measurements on 14 patients undergoing Heller myotomy with Dor fundoplication were conducted over an 18-month period. Minimum esophageal diameter, cross-sectional areas, and distensibility index were measured at 30 and 40 mL catheter volumes before myotomy, postmyotomy, and following Dor fundoplication. Distensibility index is defined as the narrowest cross-sectional area divided by the corresponding pressure expressed in mm/mm Hg. Heller myotomy was found to lead to significant changes in the distensibility characteristics of the EGJ. Minimum esophageal diameter and EGJ distensibility increased significantly with Heller myotomy.


Assuntos
Junção Esofagogástrica/cirurgia , Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Laparoscopia/métodos , Robótica/métodos , Elasticidade , Junção Esofagogástrica/fisiopatologia , Feminino , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/fisiopatologia , Humanos , Período Intraoperatório , Masculino , Manometria , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA