1.
J Am Coll Cardiol ; 81(20): 1979-1991, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37197841

RESUMO

BACKGROUND: Takotsubo syndrome (TTS) is a reversible form of heart failure with incompletely understood pathophysiology. OBJECTIVES: This study analyzed altered cardiac hemodynamics during TTS to elucidate underlying disease mechanisms. METHODS: Left ventricular (LV) pressure-volume loops were recorded in 24 consecutive patients with TTS and a control population of 20 participants without cardiovascular diseases. RESULTS: TTS was associated with impaired LV contractility (end-systolic elastance 1.74 mm Hg/mL vs 2.35 mm Hg/mL [P = 0.024]; maximal rate of change in systolic pressure over time 1,533 mm Hg/s vs 1,763 mm Hg/s [P = 0.031]; end-systolic volume at a pressure of 150 mm Hg, 77.3 mL vs 46.4 mL [P = 0.002]); and a shortened systolic period (286 ms vs 343 ms [P < 0.001]). In response, the pressure-volume diagram was shifted rightward with significantly increased LV end-diastolic (P = 0.031) and end-systolic (P < 0.001) volumes, which preserved LV stroke volume (P = 0.370) despite a lower LV ejection fraction (P < 0.001). Diastolic function was characterized by prolonged active relaxation (relaxation constant 69.5 ms vs 45.9 ms [P < 0.001]; minimal rate of change in diastolic pressure -1,457 mm Hg/s vs -2,192 mm Hg/s [P < 0.001]), whereas diastolic stiffness (1/compliance) was not affected during TTS (end-diastolic volume at a pressure of 15 mm Hg, 96.7 mL vs 109.0 mL [P = 0.942]). Mechanical efficiency was significantly reduced in TTS (P < 0.001) considering reduced stroke work (P = 0.001), increased potential energy (P = 0.036), and a similar total pressure-volume area compared with that of control subjects (P = 0.357). CONCLUSIONS: TTS is characterized by reduced cardiac contractility, a shortened systolic period, inefficient energetics, and prolonged active relaxation but unaltered diastolic passive stiffness. These findings may suggest decreased phosphorylation of myofilament proteins, which represents a potential therapeutic target in TTS. (Optimized Characterization of Takotsubo Syndrome by Obtaining Pressure Volume Loops [OCTOPUS]; NCT03726528).


Assuntos
Cardiomiopatia de Takotsubo , Humanos , Cardiomiopatia de Takotsubo/diagnóstico , Hemodinâmica , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Contração Miocárdica/fisiologia
2.
JACC Cardiovasc Interv ; 13(10): 1251-1261, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32360260

RESUMO

OBJECTIVES: The aim of this study was to assess the value of echocardiographic right ventricular (RV) and systolic pulmonary artery pressure (sPAP) assessment in predicting transcatheter tricuspid edge-to-edge valve repair (TTVR) outcome. BACKGROUND: RV dysfunction and pulmonary hypertension are associated with poor prognosis and are systematically sought during tricuspid regurgitation evaluation. The value of echocardiographic assessment in predicting TTVR outcome is unknown. METHODS: Data were taken from the TriValve (Transcatheter Tricuspid Valve Therapies) registry, which includes patients undergoing TTVR at 14 European and North American centers. The primary outcome was 1-year survival free from hospitalization for heart failure, and secondary outcomes were 1-year survival and absence of hospital admission for heart failure at 1 year. RESULTS: Overall, 249 patients underwent TTVR between June 2015 and 2018 (mean tricuspid annular plane systolic excursion [TAPSE] 15.8 ± 15.3 mm, mean sPAP 43.6 ± 16.0 mm Hg). Tricuspid regurgitation grade ≥3+ was found in 96.8% of patients at baseline and 29.4% at final follow-up; 95.6% were in New York Heart Association functional class III or IV initially, compared with 34.3% at follow-up (p < 0.05). Final New York Heart Association functional class did not differ among TAPSE and sPAP quartiles, even when both low TAPSE and high sPAP were present. Rates of 1-year survival and survival free from hospitalization for heart failure were 83.9% and 78.7%, respectively, without significant differences according to baseline echocardiographic RV characteristics (TAPSE, fractional area change, and end-diastolic area) and sPAP (p > 0.05 for all). CONCLUSIONS: TTVR provides clinical improvement, with 1-year survival free from hospital readmission >75% in patients with severe tricuspid regurgitation. Conventional echocardiographic parameters used to assess RV function and sPAP did not predict clinical outcome after TTVR.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Ecocardiografia , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia , Função Ventricular Direita , Pressão Ventricular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Progressão da Doença , Europa (Continente) , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Valor Preditivo dos Testes , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
3.
Echocardiography ; 37(3): 380-387, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32049400

RESUMO

OBJECTIVES: The aim of this study was to investigate reliability and accuracy of noninvasive measurement method by echocardiography compared to invasive measurement of systolic pulmonary artery pressure (SPAP) in a large cohort of aortic stenosis (AS) patients. BACKGROUND: Pulmonary hypertension (PH) is common in patients with cardiac disease, especially in left heart disease like severe AS. Invasive measurement by right heart catheterization (RHC) is the gold standard to assess pulmonary pressures. Nevertheless, echocardiography is widely used in everyday practice for estimation of pulmonary pressures and diagnosing PH. METHODS: A total of 1400 patients with AS and full invasive hemodynamic assessment by RHC and noninvasive measurements by Doppler echocardiography were included. RESULTS: Mean patient age was 81.5 ± 6.8 years, and 46.3% were males. SPAP was 44.7 ± 15.1 mm Hg by echocardiography and 45.3 ± 15.2 mm Hg by RHC. Pearson's correlation coefficient was r = .820 (P < .0001). Bland-Altman analysis showed a bias of -0.56 mm Hg (95% limits of agreement -18.38 to + 17.26 mm Hg) and 80.6% measurement accuracy. Pulmonary hypertension defined by RHC as a mean PAP ≥25 mm Hg was reliably diagnosed via an echocardiographically measured SPAP of >40 mm Hg (82.2% sensitivity, 80.2% specificity, 83.1% positive predictive value, 79.2% negative predictive value). CONCLUSIONS: In a large cohort of patients with severe aortic stenosis, we could demonstrate a very good correlation of SPAP between Doppler echocardiography and invasive RHC measurement. Pulmonary hypertension could be diagnosed by echocardiography with high sensitivity and specificity.


Assuntos
Estenose da Valva Aórtica , Cateterismo Cardíaco , Artéria Pulmonar , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes
4.
Artigo em Inglês | MEDLINE | ID: mdl-27301396

RESUMO

BACKGROUND: Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets for implantation that would improve hemodynamics after ViV. METHODS AND RESULTS: Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated postprocedural gradients (mean ≥20 mm Hg). Optimal implantation depths were defined by receiver operating characteristic curve. A total of 292 consecutive patients (age, 78.9±8.7 years; 60.3% male; 157 CoreValve Evolut and 135 Sapien XT) were evaluated. High implantation was associated with significantly lower rates of elevated gradients in comparison with low implantation (CoreValve Evolut, 15% versus 34.2%; P=0.03 and Sapien XT, 18.5% versus 43.5%; P=0.03, respectively). Optimal implantation depths were defined: CoreValve Evolut, 0 to 5 mm; Sapien XT, 0 to 2 mm (0-10% frame height); sensitivities, 91.3% and 88.5%, respectively. The strongest independent correlate for elevated gradients after ViV was device position (high: odds ratio, 0.22; confidence interval, 0.1-0.52; P=0.001), in addition to type of device used (CoreValve Evolut: odds ratio, 0.5; confidence interval, 0.28-0.88; P=0.02) and surgical valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). CONCLUSIONS: High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self- and balloon-expandable transcatheter valves. These clinical evaluations support specific implantation targets to optimize hemodynamics after ViV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Herz ; 34(6): 444-50, 2009 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-19784562

RESUMO

Standard therapy of advanced mitral valve regurgitation currently consists of mitral valve reconstruction through heart surgery including heart-lung machine employment. Typically, a ring is implanted and a leaflet reduced, if necessary, to approximate the posterior and anterior mitral valve leaflets to each other. Because of high comorbidity among this patient population, new and less burdening catheter-based techniques have been developed. Clinical etiology of mitral valve regurgitation is divided into two categories: "structural" versus "functional". The MONARC system of the Edwards Lifesciences company consists of three components--distal stent, bridge with bioabsorbing coating, proximal stent--and is implanted into the coronary sinus. The underlying principle is an indirect annuloplasty of the mitral valve annulus resulting from resorption of the bridge coating and leading to a reduction and indirect tightening of the mitral valve annulus. The EVOLUTION I (EV I) study in patients suffering from functional mitral regurgitation to a degree between 2+ and 4+ revealed--12 months after the MONARC implantation--a mitral valve regurgitation reduction from 2.48 to 1.78. The EV I study found interaction of the foreshortening bridge with the coronary arteries in some patients. This problem is most widely excluded by previous computed tomographic or angiographic examinations in the ongoing follow-up study EV II. Direct annuloplasty is made possible in case of functional mitral regurgitation by using the Mitralign Percutaneous Annuloplasty System (MPAS) of the Mitralign company. In doing so, an improved coadaptation of the mitral valve leaflet is achieved by inserting three sutures into the posterior mitral valve annulus and subsequent plicating.The MitraClip of the Evalve company uses the principle of the edge-to-edge technique. In doing so, the posterior and anterior leaflets are joined by implanting a clip, resulting in a reduction of mitral regurgitation with two diastolic orifices. In contrast to strukthe other two procedures, the MitraClip can be used for both functional and structural mitral valve regurgitation. The EVEREST I study and the EVEREST II study, as far as it has already been published, show that this procedure is secure and its results are very positive. The previous results of all three procedures show that catheter-based techniques for treating high-risk patients suffering from mitral valve regurgitation arrive at positive results in part, so that possibly a real alternative to conventional heart surgery will be available in the future.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Stents , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Desenho de Prótese , Avaliação da Tecnologia Biomédica
SELEÇÃO DE REFERÊNCIAS