Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Curr Probl Diagn Radiol ; 43(4): 162-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24948209

RESUMO

To compare diagnostic accuracy of contrast-enhanced computed tomographic angiography (CTA) and gadolinium-enhanced magnetic resonance angiography (MRA) for the assessment of hemodynamically significant transplant renal artery stenosis (TRAS). After institutional review board approval, records of 27 patients with TRAS confirmed on digital subtraction angiography (DSA) were retrospectively reviewed. A total of 13 patients had MRA and 14 had CTA before DSA. Two board-certified fellowship-trained radiologists, one each from interventional radiology and body imaging blindly reviewed the DSA and CTA or MRA data, respectively. Sensitivity (SN), specificity (SP), positive predictive value, and negative predictive value of MRA and CTA were estimated using 50% stenosis as the detection threshold for significant TRAS. These parameters were compared between modalities using the Fisher exact test. Bias between MRA or CTA imaging and DSA was tested using the Wilcoxon signed-rank test. Two patients were excluded from the MRA group owing to susceptibility artifacts obscuring the TRAS. The correlation between MRA and DSA measurements of stenosis was r = 0.57 (95% CI:-0.02, 0.87; P = 0.052) and between CTA and DSA measurements was r = 0.63 (95% CI: 0.14, 0.87; P = 0.015); the difference between the 2 techniques was not significant (P = 0.7). Both imaging modalities tended to underestimate the degree of stenosis when compared with DSA. MRA group (SN and SP: 56% and 100%, respectively) and CTA group (SN and SP: 81% and 67%, respectively). There were no significant differences in detection performance between modalities (P>0.3 for all measures). We did not find that either modality had any advantage over the other in terms of measuring or detecting significant stenosis. Accordingly, MRA may be preferred over CTA after positive color Doppler ultrasound screening when not contraindicated owing to lack of ionizing radiation or nephrotoxic iodinated contrast. However, susceptibility of artifacts owing to surgical clips at the anastomosis may limit diagnostic utility of MRA as found in 2 of 13 patients. Trend towards no significant difference between the CTA and enhanced MRA in the detection of hemodynamically significant TRAS.


Assuntos
Angiografia , Meios de Contraste , Gadolínio , Transplante de Rim/efeitos adversos , Imageamento por Ressonância Magnética , Obstrução da Artéria Renal/diagnóstico , Tomografia Computadorizada por Raios X , Angiografia/métodos , Angiografia/normas , Feminino , Humanos , Aumento da Imagem , Masculino , Valor Preditivo dos Testes , Obstrução da Artéria Renal/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA