Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Br J Radiol ; 86(1021): 20120238, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255542

RESUMO

OBJECTIVE: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. METHODS: In six ex vivo left anterior descending coronary arteries immersed in oil, CT (slices/collimation 64×0.625 mm, temporal resolution 210 ms, pitch 0.2) was performed after intracoronary injection of a saline solution, and solutions of a dimeric isosmolar contrast medium (Iodixanol 320 mgI ml(-1)) and a monomeric high-iodinated contrast medium (Iomeprol 400 mgI ml(-1)) with dilutions of 1/80 (low concentration), 1/50 (medium concentration), 1/40 (high concentration) and 1/20 (very high concentration). Two radiologists drew regions of interest in the lumen and in calcified and non-calcified plaques for each solution. 29 cross-sections with non-calcified plaques and 32 cross-sections with calcified plaques were evaluated. RESULTS: Both contrast media showed different attenuation values within lumen and plaque (p<0.0001). The correlation between lumen and non-calcified plaque values was good (Iodixanol r=0.793, Iomeprol r=0.647). Clustered medium- and high-concentration solutions showed similar plaque attenuation values, signal-to-noise ratios (SNRs) (non-calcified plaque: medium solution SNR 31.3±15 vs 31.4±20, high solution SNR 39.4±17 vs 37.4±22; calcified plaque: medium solution SNR 305.2±133 vs 298.8±132, high solution SNR 323.9±138 vs 293±123) and derived contrast-to-noise ratios (p>0.05). CONCLUSION: Differently iodinated contrast media have a similar influence on plaque attenuation profiles. ADVANCES IN KNOWLEDGE: Since iodine load affects coronary plaque attenuation linearly, different contrast media may be equally employed for coronary atherosclerotic plaque imaging.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Iopamidol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Técnicas In Vitro , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ácidos Tri-Iodobenzoicos/administração & dosagem
2.
Radiol Med ; 109(5-6): 500-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15973223

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of multislice computed tomography coronary angiography (MSCT-CA) in the detection of in-stent restenosis. MATERIALS AND METHODS: Forty-two patients (33 male, 9 female, mean age 58+/-8 years) previously subjected to percutaneous implantation of coronary stent with suspected in-stent restenosis, underwent a 16-row MSCT (Sensation 16, Siemens) examination. The average time between stent implantation and MSCT-CA was 7.4+/-5.3 months. The following scan parameters were used: collimation 16x0.75 mm, rotation time 0.42 s, feed 3.0 mm/rot., kV 120, mAs 500. After administration of iodinated contrast material (Iomeprol 400 mgI/ml, 100 ml at 4 ml/s) and bolus chaser (40 ml of saline at 4 ml/s) the scan was completed in <20 s. All segments with a stent were assessed by two observers in consensus and were graded according to the following scheme: patent stent, in-stent intimal hyperplasia (IIH) (lumen reduction <50%), in-stent restenosis (ISR) (=/>50%), in-stent occlusion (ISO) (100%). Consensus reading was compared with coronary angiography. RESULTS: Forty-seven stents were assessed (16 in the right coronary artery; 4 in the left main; 22 in the left anterior descending; 5 in the circumflex). In 7 (17%) stents there was ISR (3) or ISO (4), and in 4 (10%) stents there was IIH. The sensitivity and negative predictive values for the detection of ISO were 80% and 98%, respectively, while for the detection of ISR+ISO they were 50% and 89%, respectively. CONCLUSIONS: Although the results are encouraging, the follow-up of stent patency with MSCT-CA does not show a diagnostic accuracy suitable for clinical implementation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA