Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Cardiol ; 168(5): 4717-22, 2013 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-23948116

RESUMO

OBJECTIVES: To angiographically assess myocardial perfusion in patients with Tako-Tsubo syndrome (TTS) in comparison with control individuals and patients with ST-elevation myocardial infarction (STEMI). BACKGROUND: Coronary microvascular dysfunction has been proposed as the pathophysiological mechanism underlying TTS. METHODS: We retrospectively selected consecutive TTS patients showing typical left ventricular (LV) apical dysfunction admitted to our Department in the period 2007-2011 (n=25). We also enrolled an age and gender-matched control group showing normal coronary arteries (CTR, n=25), patients with STEMI undergoing primary percutaneous intervention with myocardial reperfusion (SR, n=25) or microvascular obstruction (SMVO, n=25). TIMI flow, TIMI frame count (TFC) and both qualitative and quantitative myocardial blush grade in LV apex were assessed. Specifically, myocardial perfusion was quantitatively evaluated using 'Quantitative Blush Evaluator' (QuBE), an open source software previously validated in the setting of STEMI. RESULTS: In TTS, TIMI flow on the LAD was significantly lower and TFC significantly higher compared to CTR and SR (p=0.008 for both), while it did not significantly differ compared to SMVO (p=0.06). In TTS, MBG was significantly lower than that in CTR and SR (p=0.001 for both), while it was significantly higher than that in SMVO (p<0.001). In TTS, QuBE score was significantly lower than that in CTR and SR (p=0.001 for both) and higher than in SMVO (p=0.02). CONCLUSIONS: Our data indicate that myocardial perfusion assessed during angiography is more impaired in patients with TTS than in patients with STEMI exhibiting myocardial reperfusion, while it is less impaired than in patients with STEMI exhibiting MVO.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Idoso , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Microcirculação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Cardiomiopatia de Takotsubo/fisiopatologia
2.
Am Heart J ; 160(6): 1015-22, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21146652

RESUMO

Assessment of myocardial "blush" by either Myocardial Blush Grade or TIMI Myocardial Perfusion Grade, is the angiographic method currently preferred to confirm myocardial tissue-level perfusion after primary percutaneous intervention. This review focuses on the utility of angiographic "blush" as a simple, widely available, and virtually costless technique for the immediate diagnosis of microvascular impairment at the time of acute catheterization. We comprehensively outline the available evidence behind the "blush," its use in clinical practice, and draw comparisons with other new technologies for assessment of microvascular integrity.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Microcirculação , Infarto do Miocárdio/diagnóstico por imagem , Angioplastia Coronária com Balão , Humanos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Índice de Gravidade de Doença
3.
Int J Cardiovasc Imaging ; 22(3-4): 417-28, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16496094

RESUMO

BACKGROUND: Information on the accuracy of both magnetic resonance imaging (MRI) and myocardial contrast echocardiography (MCE) for the identification of perfusion defects in patients with acute myocardial infarction is limited. We evaluated the accuracy of MRI and MCE, using Single Photon Emission Computed Tomography (SPECT) imaging as reference technique. METHODS: Fourteen consecutive patients underwent MCE, MRI and 99mTc-MIBI SPECT after acute myocardial infarction to assess myocardial perfusion. MCE was performed by Harmonic Power Angio Mode, with end-systolic triggering 1:4, using i.v. injection of Levovist. First-pass and delayed enhancement MRI was obtained after i.v administration of Gadolinium-DTPA. At MCE, homogeneous perfusion was considered as normal and absent or "patchy" perfusion as abnormal. At MRI, homogenous contrast enhancement was defined as normal whereas hypoenhancement at first-pass followed by hyperenhancement or persisting hypoenhancement in delayed images was defined as abnormal. RESULTS: At MCE 153 (68%) of segments were suitable for analysis compared to 220 (98%) segments at MRI (p<0.001). Sensitivity, specificity and accuracy of MCE for segmental perfusion defects in these 153 segments were 83, 73 and 77%, respectively. Sensitivity, specificity and accuracy of MRI were 63, 82, and 77%, respectively. MCE and MRI showed a moderate agreement with SPECT (k: 0.52 and 0.46, respectively). The agreement between MCE and MRI was better (k: 0.67) that the one of each technique with SPECT. CONCLUSION: MCE and MRI may be clinically useful in the assessment of perfusion defects in patients with acute myocardial infarction, even thought MCE imaging may be difficult to obtain in a considerable proportion of segments when the Intermittent Harmonic Angio Mode is used.


Assuntos
Circulação Coronária , Ecocardiografia , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Meios de Contraste , Feminino , Gadolínio DTPA , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Polissacarídeos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
4.
J Am Soc Echocardiogr ; 15(3): 197-205, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11875381

RESUMO

BACKGROUND: Myocardial contrast echocardiography (MCE) has potential value in the assessment and quantitation of myocardial perfusion defects. However, the severity of stenosis detectable by MCE and its diagnostic accuracy remain undefined. Thus, we produced coronary stenoses of variable severity and quantified their effect on MCE. METHODS AND RESULTS: Three grades of left anterior descending (LAD) obstructions were produced in 7 open-chest swine. The stenoses were nonflow-limiting at rest, but decreased coronary hyperemia by 31.3% +/- 4.7%, 69.9% +/- 5.3% and 98.9% +/- 1.1%, respectively. Regional myocardial blood flow (RBF) was measured with fluorescent microspheres and was expressed as the ratio of LAD and control (LCx) beds. MCE was performed with 0.3 mg/kg intravenous AF0150 during ECG-gated harmonic imaging in short-axis view. Background-subtracted peak intensity (PI) was expressed as the ratio of LAD/LCx beds. Both RBF and PI ratios progressively decreased with increasing grades of stenosis. MCE showed a significant correlation with RBF (r = 0.74; P <.0001). Ratios of both PI and RBF differed significantly from baseline when coronary hyperemia was reduced more than 50%. An LAD/LCx ratio less than 0.6 by MCE yielded 61% and 83% sensitivity and 85% and 76% specificity with stenosis that reduced coronary hyperemia more than 50% and more than 75%, respectively. CONCLUSION: MCE with intravenous AF0150 during vasodilation correctly depicted the progressive reduction of flow ratios produced by graded coronary stenoses. A significant reduction of PI ratio was observed with stenosis causing more than 50% reduction of coronary hyperemia. An MCE ratio in stenosed/control beds could be selected, which exhibited good sensitivity and specificity in the identification of coronary stenosis.


Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Ecocardiografia/métodos , Animais , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Modelos Animais , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Suínos , Vasodilatação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA