Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Med Eng Phys ; 126: 104144, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38621846

RESUMO

The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.


Assuntos
Fenômenos Fisiológicos Cardiovasculares , Smartphone , Reologia/métodos , Velocidade do Fluxo Sanguíneo , Imagens de Fantasmas
2.
Int J Cardiol ; 334: 1-9, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33933514

RESUMO

BACKGROUND: Morphological evaluation of coronary lesion length is a paramount step during invasive assessment of coronary artery disease. Likewise, the extent of epicardial pressure losses can be measured using longitudinal vessel interrogation with fractional flow reserve (FFR) pullbacks. We aimed to quantify the mismatch in lesion length between morphological (based on quantitative coronary angiography, QCA, and optical coherence tomography, OCT) and functional evaluations. METHODS: This is a prospective and multicenter study of patients evaluated by QCA, OCT and motorized fractional flow reserve pullbacks (mFFR). The difference in lesion length between the functional and anatomical evaluations was referred to as FAM. RESULTS: 117 patients (131 vessels) were included. Median lesion length derived from angiography was 16.05 mm [11.40-22.05], from OCT was 28.00 mm [16.63-38.00] and from mFFR 67.12 mm [25.38-91.37]. There was no correlation between QCA and mFFR lesion length (r = 0.124, 95% CI -0.168-0.396, p = 0.390). OCT lesion length did correlate with mFFR (r = 0.469, 95% CI 0.156-0.696, p = 0.004). FAM was strongly associated with the improvement in vessel conductance with percutaneous coronary intervention (PCI), higher mismatch was associated with lower post-PCI FFR. CONCLUSIONS: Lesion length assessment differs between morphological and functional evaluations. The morphological-functional mismatch in lesion length is frequent, and influences the results of PCI in terms of post-PCI FFR. Integration of the extent of pressure losses provides clinically relevant information that may be useful for clinical decision-making concerning revascularization strategy.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos
3.
Med Eng Phys ; 85: 7-15, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33081966

RESUMO

Decellularized extracellular matrix is one of the most promising biological scaffold supporting in vitro tissue growth and in vivo tissue regeneration in both preclinical research and clinical practice. In case of thick tissues or even organs, conventional static decellularization methods based on chemical or enzymatic treatments are not effective in removing the native cellular material without affecting the extracellular matrix. To overcome this limitation, dynamic decellularization methods, mostly based on perfusion and agitation, have been proposed. In this study, we developed a low-cost scalable 3D-printed sample-holder for agitation-based decellularization purposes, designed for treating multiple specimens simultaneously and for improving efficiency, homogeneity and reproducibility of the decellularization treatment with respect to conventional agitation-based approaches. In detail, the proposed sample-holder is able to house up to four specimens and, immersed in the decellularizing solution within a beaker placed on a magnetic stirrer, to expose them to convective flow, enhancing the solution transport through the specimens while protecting them. Computational fluid dynamics analyses were performed to investigate the fluid phenomena establishing within the beaker and to support the sample-holder design. Exploratory biological tests performed on human skin specimens demonstrated that the sample-holder reduces process duration and increases treatment homogeneity and reproducibility.


Assuntos
Matriz Extracelular , Engenharia Tecidual , Humanos , Perfusão , Impressão Tridimensional , Reprodutibilidade dos Testes , Alicerces Teciduais
4.
Am J Cardiovasc Drugs ; 20(3): 259-269, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31586336

RESUMO

INTRODUCTION: Real-life data comparing clopidogrel, prasugrel, and ticagrelor for unselected patients undergoing percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) are lacking, as are data for the temporal distribution of ischemic and bleeding risks. METHODS: A total of 19,825 patients were enrolled from the RENAMI and BleeMACS registries. Both were multicenter, retrospective, observational registries including the data and outcomes of consecutive patients with ACS who underwent primary PCI and were discharged with dual antiplatelet therapy (DAPT). We evaluated the long-term outcome stratified by the different antiplatelet agents. RESULTS: A total of 14,105 patients (71.2%) were treated with clopidogrel, 2364 patients (11.9%) with prasugrel and 3356 patients (16.9%) with ticagrelor. After propensity score matching, at 1 year, prasugrel reduced the incidence of net adverse clinical events (NACE; a composite endpoint of all-cause death, myocardial infarction [MI] and Bleeding Academic Research Consortium [BARC] 3-5 bleeding) (4.2% vs.7.6%, p = 0.002) and of major adverse cardiovascular events (MACE; a composite endpoint of death and MI) compared with clopidogrel (2.6% vs. 5.2%, p = 0.007). Ticagrelor decreased rates of MACE compared with clopidogrel (2.7% vs. 6.2%, p < 0.001), but not of NACE (6.6% vs. 8.7%, p = 0.07). Ticagrelor presented similar performance in terms of MACE compared with prasugrel (2.8% vs. 2.4%, p = 0.56), with a trend towards a reduction in MI (0.2% vs. 0.4%, p = 0.56), but with higher risk of BARC 3-5 bleedings (3.8% vs. 1.7%, p = 0.04). In the daily risk analysis, clopidogrel presented a binomial distribution with a peak of ischemic risk at 3 months, which decreased towards bleedings; prasugrel had a constant equivalence between opposite risks; and ticagrelor constantly reduced recurrent MIs despite higher risk of BARC 3-5 events. CONCLUSION: In real life, ticagrelor is more effective in reducing ischemic events during the first year after ACS, despite an increased risk of major bleedings, while prasugrel assures a better balance between ischemic and bleeding recurrent events.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Clopidogrel , Hemorragia , Infarto do Miocárdio , Intervenção Coronária Percutânea , Cloridrato de Prasugrel , Ticagrelor , Síndrome Coronariana Aguda/epidemiologia , Clopidogrel/administração & dosagem , Clopidogrel/efeitos adversos , Clopidogrel/farmacocinética , Europa (Continente)/epidemiologia , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Conduta do Tratamento Medicamentoso/estatística & dados numéricos , Pessoa de Meia-Idade , Mortalidade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/farmacocinética , Cloridrato de Prasugrel/administração & dosagem , Cloridrato de Prasugrel/efeitos adversos , Cloridrato de Prasugrel/farmacocinética , Sistema de Registros/estatística & dados numéricos , Risco Ajustado/métodos , Equivalência Terapêutica , Ticagrelor/administração & dosagem , Ticagrelor/efeitos adversos , Ticagrelor/farmacocinética
5.
Comput Methods Biomech Biomed Engin ; 20(10): 1104-1112, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28553722

RESUMO

This study investigates the impact that uncertainty in phase contrast-MRI derived inlet boundary conditions has on patient-specific computational hemodynamics models of the healthy human thoracic aorta. By means of Monte Carlo simulations, we provide advice on where, when and how, it is important to account for this source of uncertainty. The study shows that the uncertainty propagates not only to the intravascular flow, but also to the shear stress distribution at the vessel wall. More specifically, the results show an increase in the uncertainty of the predicted output variables, with respect to the input uncertainty, more marked for blood pressure and wall shear stress. The methodological approach proposed here can be easily extended to study uncertainty propagation in both healthy and pathological computational hemodynamic models.


Assuntos
Aorta Torácica/fisiologia , Hemodinâmica , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Incerteza , Adulto , Aorta , Pressão Sanguínea , Simulação por Computador , Humanos , Masculino , Microscopia de Contraste de Fase , Método de Monte Carlo , Razão Sinal-Ruído , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA