Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
JACC Cardiovasc Interv ; 2(2): 97-106, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19463409

RESUMO

OBJECTIVES: We sought to examine angiographic and clinical outcomes with sirolimus-eluting stents (SES) in total coronary occlusion (TCO) revascularization. BACKGROUND: Despite evaluation of drug-eluting stents beyond approved indications, few studies have evaluated their clinical benefit in TCO revascularization. METHODS: Among 15 centers in North America, 200 consecutive TCO patients (78.8% >6 weeks TCO age) were enrolled for treatment with SES. The primary end point was 6-month angiographic binary restenosis within the treated segment. RESULTS: Patient characteristics included: diabetes, 24.5%; prior infarction, 33.5%; and stent length, 45.9 mm median (quartile 1, 30.2 mm; quartile 2, 62.1 mm). A total of 199 patients (99.5%) were treated with SES, and procedural success was 98.0%. The 6-month binary restenosis rates were 9.5% in-stent, 12.4% in-segment, and 22.6% in-"working length" representing the entire treatment segment. Rates of 1-year target lesion revascularization, myocardial infarction, and target vessel failure were 9.8%, 1.0%, and 10.9%, respectively. Stent thrombosis occurred in 2 patients (1.0%). Using logistic regression modeling with propensity score adjustment, the absolute reduction in binary restenosis with SES compared with a historical bare-metal stent control was 37.7% (95% confidence interval [CI]: 27.2% to 48.3%, p < 0.001; odds ratio: 0.17, 95% CI: 0.09 to 0.30, p < 0.0001). Among 32 patients (16%) identified with stent fracture, target lesion revascularization was more common than patients without fracture (25.0% vs. 6.7%, p = 0.005). CONCLUSIONS: Despite greater lesion complexity than prior TCO trials, percutaneous revascularization with SES appears safe and results in substantial reductions in angiographic restenosis and failed patency and a low rate of repeat revascularization. These findings support the use of SES in TCO revascularization. (The ACROSS/TOSCA Trial; NCT00378612).


Assuntos
Reestenose Coronária/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Imunossupressores/uso terapêutico , Sirolimo/uso terapêutico , Idoso , Intervalos de Confiança , Angiografia Coronária , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/terapia , Reestenose Coronária/tratamento farmacológico , Vasos Coronários/patologia , Feminino , Indicadores Básicos de Saúde , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Prospectivos , Grau de Desobstrução Vascular
2.
Am Heart J ; 150(4): 659-65, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16209961

RESUMO

BACKGROUND: Noninvasive methods are needed to evaluate reperfusion success in patients with acute myocardial infarction (MI). The AMISTAD trial was analyzed to compare MI size and myocardial salvage determined by electrocardiogram (ECG) with technetium Tc 99m sestamibi single-photon emission computerized tomography (SPECT) imaging. METHODS: Of 236 patients enrolled in AMISTAD, 166 (70 %) with no ECG confounding factors and no prior MI were included in this analysis. Of these, group 1 (126 patients, 53%) had final infarct size (FIS) available by both ECG and SPECT. Group 2 (56 patients, 24%) had myocardium at risk, FIS, and salvage index (SI) assessed by both SPECT and ECG techniques. Aldrich/Clemmensen scores for myocardium at risk and the Selvester QRS score for final MI size were used. Salvage index was calculated as follows: SI = (myocardium at risk-FIS)/(myocardium at risk). RESULTS: In group 1, FIS was 15% (6, 24) as measured by ECG and 11% (2, 27) as measured by SPECT. In the adenosine group, FIS was 12% (6, 21) and 11% (2, 22). In the placebo group, FIS was 16.5% (7.5, 24) and 11.5% (3.0, 38.5) by ECG and SPECT, respectively. The overall correlation between SPECT and ECG for FIS was 0.58 (P = .0001): 0.60 in the placebo group (P = .0001) and 0.54 (P = .0001) in the adenosine group. In group 2, myocardium at risk was 23% (17, 30) and 26% (10, 50) with ECG and SPECT, respectively (P = .0066). Final infarct size was 17% (6, 21) and 12% (1, 24) (P < .0001). The SI was 29% (-7, 57) and 46% (15, 79) with ECG and SPECT, respectively (P = .0510). CONCLUSIONS: The ECG measurement of infarct size has a moderate relationship with SPECT infarct size measurements in the population with available assessments. This ECG algorithm must further be validated on clinical outcomes.


Assuntos
Adenosina/uso terapêutico , Eletrocardiografia , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/patologia , Terapia Trombolítica , Humanos , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA