Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Thorac Dis ; 10(1): 283-290, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29600058

RESUMO

BACKGROUND: Mitral valve (MV) coaptation is very important in MV repair patients. But accurate quantitation of the degree of MV coaptation remains challenging. This study aimed to evaluate the utility of two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) to assess MV coaptation before and after MV repair. METHODS: Forty-eight patients [(age: 52.23±13.31 years; 26 men (54.17%)] undergoing MV repair for mitral regurgitation (MR) were studied. We assessed the utility of 2D and 3D TEE to assess MV coaptation before and after MV repair. Complete conventional 2D and 3D TEE studies were performed, and the degree of the MV coaptation defect before and after surgery was assessed by measuring the MV coaptation length (CL) and length index (CLI) with 2D TEE, and the coaptation area (CA) and coaptation area index (CAI) with 3D TEE. RESULTS: CL and CLI were measured successfully in 46 (95.83%) patients and CA and CAI in 39 (81.25%). Compared with preoperatively, postoperative CL, CLI, CA, and CAI were significantly increased (CL: 4.99±0.79 to 9.66±1.09 mm, P<0.05; CLI: 9.30%±2.66% to 38.24%±3.82%, P<0.05; CA: 158.49±64.17 to 371.33±143.57 mm2, P<0.05; CAI: 9.71%±2.76% to 36.24%±7.26%, P<0.05). Spearman's rank correlation analysis revealed that the CLI and CAI had a significant negative correlation with the degree of MR (r=-0.97, P<0.01; r=-0.92, P<0.01, respectively). Furthermore, Pearson's correlation analysis revealed that the CLI was significantly correlated with the CAI both preoperatively (r=-0.66, P<0.01) and postoperatively (r=-0.67, P<0.01). CONCLUSIONS: The coaptation variables increased significantly in patients undergoing MV repair. The CLI and CAI significantly correlated with MR severity. The CL and CLI determined with 2D TEE are more feasible than the CA and CAI determined with 3D TEE. Both 2D and 3D variables may complement each other for aiding MV repair. 2D CLI is an alternative to 3D CAI due to its simplicity.

2.
J Am Coll Cardiol ; 63(12): 1159-1168, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24509270

RESUMO

OBJECTIVES: The objective of this study was to evaluate the safety and efficacy of the surgical versus transcatheter approach to correct perimembranous ventricular septal defects (pmVSDs) in a prospective, randomized, controlled clinical trial. BACKGROUND: pmVSD is a common congenital heart disease in children. Surgical closure of pmVSD is a well-established therapy but requires open-heart surgery with cardiopulmonary bypass. Although the transcatheter approach is associated with significant incidence of complete atrioventricular block, it may provide a less invasive alternative. Critical comparison of the safety and efficacy of the 2 interventions necessitates a prospective, randomized, controlled trial. METHODS: Between January 2009 and July 2010, 229 children with pmVSD were randomly assigned to surgical or transcatheter intervention. Clinical, laboratory, procedural, and follow-up data over a 2-year period were compared. RESULTS: Neither group had mortality or major complications. However, statistical analysis of the 2 groups demonstrated significant differences (p < 0.001) in minor adverse events (32 vs. 7), quantity of blood transfused, duration of the procedure, median hospital stay, median intensive care unit stay, median hospitalization cost, and median blood loss. During a median follow-up of 2 years, the left ventricular end-diastolic dimension of both groups returned to normal and there was no difference in closure rate, adverse events, and complications between groups. CONCLUSIONS: Transcatheter device closure and surgical repair are effective interventions with excellent midterm results for treating pmVSD in children. Transcatheter device closure has a lower incidence of myocardial injury, less blood transfused, faster recovery, shorter hospital stay, and lower medical expenses. (Transcatheter Closure Versus Surgery of Perimembranous Ventricular Septal Defects; NCT00890799).


Assuntos
Cateterismo Cardíaco , Ponte Cardiopulmonar , Comunicação Interventricular/cirurgia , Dispositivo para Oclusão Septal , Alanina Transaminase/sangue , Aspartato Aminotransferases/sangue , Perda Sanguínea Cirúrgica , Transfusão de Sangue/estatística & dados numéricos , Nitrogênio da Ureia Sanguínea , Criança , Pré-Escolar , Creatinina/sangue , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Feminino , Comunicação Interventricular/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Hospitalização/economia , Humanos , Unidades de Terapia Intensiva Pediátrica , Tempo de Internação/estatística & dados numéricos , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Troponina I/sangue , Septo Interventricular/diagnóstico por imagem
3.
PLoS One ; 8(3): e58494, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23516490

RESUMO

OBJECTIVES: We sought to determine the feasibility and reproducibility of real-time 3-dimensional echocardiography (RT3DE) for evaluation of cardiac volume, mass, and function and to characterize maturational changes of these measurements in human fetuses. METHODS: Eighty pregnant women in the 2(nd) and 3(rd) trimesters (59 with normal fetuses and 21 with fetuses with congenital heart disease [CHD]) were enrolled. We acquired RT3DE images using a matrix-array transducer. RT3DE measurements of volume, mass, stroke volume (SV), combined cardiac output (CCO), and ejection fraction (EF) were obtained. Images were scored and analyzed by two blinded independent observers. Inter- and intraobserver variabilities and correlations between fetal cardiac indices and gestational age were determined. RESULTS: Fifty-two of 59 normal data sets (88%) and 9 of 21 CHD data sets (43%) were feasible for analysis. In normal fetuses, the right ventricle (RV) is larger than the left ventricle (LV) (P<0.05), but no difference exists between the LV and RV in mass, SV, CO, and CO/CCO. The EFs for the LV and RV were diminished; the RVSV/LVSV was reduced in CHD fetuses compared with normal fetuses (P<0.05). Fetal ventricular volumes, mass, SV, and CCO fit best into exponential curves with gestational age, but LVEF, RVEF, and RVSV/LVSV remain relatively constant. CONCLUSIONS: RT3DE is feasible and reproducible for assessment of LV and RV volume, mass, and function, especially in normal fetuses. Gestational growth of these measures, except for EF, is exponential in normal and CHD fetuses. CHD fetuses exhibit diminished LV and RV EFs.


Assuntos
Ecocardiografia Tridimensional/métodos , Feto/fisiologia , Ventrículos do Coração/embriologia , Função Ventricular/fisiologia , Adolescente , Adulto , Estudos de Viabilidade , Feminino , Humanos , Variações Dependentes do Observador , Tamanho do Órgão , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
4.
Echocardiography ; 27(6): 709-15, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20653763

RESUMO

BACKGROUND: Loss of synchronous contraction between or within the right and left ventricle (RV, LV) leads to adverse ventricular function. We used real time three-dimensional echocardiography (RT3DE) for evaluation of severity of interventricular dyssynchrony and function in a porcine heart model. METHODS: Six fresh in vitro porcine hearts were used to create a controlled model of LV and RV dyssynchrony using two sets of pulsatile pumps. Synchronized and dyssynchronized pump settings were used with two different dyssynchronized settings: LV filled first and RV filled first. RESULTS: There was good correlation between actual measurement and RT3DE for interventricular time difference (r = 0.95, P < 0.0001) and stroke volume (SV) for LV and RV (0.89, 0.85; P < 0.0001, respectively). RT3DE data showed a small but significant underestimation for actual volume (P < 0.05). The intra- and interobserver variabilities are 2.9 +/- 1.5% and 3.1 +/- 5.4% for LV and RV SVs, and 1.7 +/- 2.4% and 2.2 +/- 3.2% for time differences by RT3DE. There was significant difference in RV SV between synchrony and dyssynchrony when the RV filled first (P < 0.05), but not in other groups. The same pattern was found in RT3DE derived SVs (synchrony versus dyssynchrony with RV filled first, P < 0.05). CONCLUSIONS: There is no compromise in LV SV during interventricular dyssynchrony; but RV SV was significantly diminished when the RV filled first. RT3DE is a feasible, robust and reproducible method to identify interventricular dyssynchrony and to evaluate ventricular SVs.


Assuntos
Algoritmos , Modelos Animais de Doenças , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Animais , Sistemas Computacionais , Humanos , Aumento da Imagem/métodos , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Direita/complicações
5.
J Am Soc Echocardiogr ; 21(1): 84-9, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17628408

RESUMO

BACKGROUND: Measurement of right ventricular (RV) volumes and ejection fraction (EF) by two-dimensional echocardiography has limited accuracy and reproducibility because of the complex RV geometry. OBJECTIVES: This study sought to validate real-time three-dimensional echocardiography (RT3DE) using a disk summation method for assessment of RV volumes and RVEF in children by comparing it with magnetic resonance imaging (MRI) measurements. METHODS: A total of 20 children (mean age 10.6 +/- 2.8 years) were studied. Transthoracic RT3DE was performed using a RT3DE system to acquire full-volume RT3DE data sets from apical windows and data were processed offline using a software package. RV end-systolic volume and end-diastolic volume (EDV) were measured using a disk summation method by manually tracing the endocardial borders. RVEF was calculated as: RVEF = (EDV - end-systolic volume)/EDV x 100%. All participants also underwent MRI studies for comparison of RV indexes. RESULTS: Of the 20 children, 3 were excluded because of poor or incomplete RV images (two RT3DE and one MRI study). For the remaining 17 children, good correlation and agreement between RT3DE and MRI were found (RVEDV: r = 0.98, P < .001, mean difference = -7.0 +/- 9.0 mL, P < .01; RV end-systolic volume: r = 0.96, P < .001, mean difference = -3.2 +/- 7.1 mL, P > .05; RVEF: r = 0.89, P < .001, mean difference = -0.3 +/- 7.1%, P > .05). The intraobserver and the interobserver variabilities ranged from -1.1% to 5.8%. CONCLUSION: Measurement of RV volumes and EF by RT3DE is feasible, accurate, and reproducible in children compared with MRI measurements.


Assuntos
Ecocardiografia Tridimensional , Ventrículos do Coração , Volume Sistólico , Função Ventricular Direita/fisiologia , Adolescente , Criança , Eletrocardiografia , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Fatores de Tempo , Função Ventricular
6.
J Am Soc Echocardiogr ; 18(4): 299-305, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15846155

RESUMO

OBJECTIVE: We sought to assess the feasibility, accuracy, and reproducibility of a rapid full volume acquisition strategy using real-time (RT) 3-dimensional (3D) echocardiography (3DE) for measurement of left ventricular (LV) volumes, mass, stroke volume (SV), and ejection fraction (EF) in children. METHODS: A total of 19 healthy children (mean 10.6 +/- 2.8 years, 11 male and 9 female) were prospectively enrolled in this study. RT 3DE was performed using an ultrasound system to acquire full volume 3D dataset from the apical window with electrocardiographic triggering in 8 s/dataset. The images were processed offline using software. The LV endocardial and epicardial borders were traced manually to derive LV end-systolic volume, end-diastolic volume, mass, SV, and EF. Magnetic resonance imaging (MRI) studies were performed on a 1.5-T scanner using a breath hold 2-dimensional cine-FIESTA (fast imaging employing steady-state acquisition) sequence. RESULTS: All RT 3DE and MRI data were acquired successfully for analysis. Measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF by RT 3DE correlated well by Pearson regression ( r = 0.86-0.97, P < .001) and agreed well by Bland-Altman analysis with MRI. The interobserver and intraobserver variability of RT 3DE measurements were less than 5%. CONCLUSIONS: This prospective study demonstrated that RT 3DE measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF in children using rapid full volume acquisition strategy are feasible, accurate, and reproducible and are comparable with MRI measurements.


Assuntos
Ecocardiografia Tridimensional , Imageamento por Ressonância Magnética , Função Ventricular Esquerda/fisiologia , Adolescente , Criança , Feminino , Humanos , Masculino , Estudos Prospectivos , Análise de Regressão , Reprodutibilidade dos Testes , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA