Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Orv Hetil ; 160(14): 540-548, 2019 Apr.
Artigo em Húngaro | MEDLINE | ID: mdl-30931601

RESUMO

INTRODUCTION: Levels of cardiac necroenzymes, high-sensitive troponin (hsTnT) and creatine kinase muscle-brain (CKMB) increase as a result of a myocardial damage following catheter ablation. AIM: To analyze the mid-term alteration of hsTnT and CKMB levels following radiofrequency ablation (RFCA) for atrial fibrillation (AF), atrial flutter (AFlu), AV-nodal reentry tachycardia (AVNRT) and electrophysiological studies (EPS) without ablation. METHOD: Patients undergoing RFCA for various indications and EPS were consecutively enrolled in our prospective study. Concentrations of hsTnT and CKMB were measured from serial blood samples directly before and after the procedure, 4 and 20 hours later and at 3 months follow-up. RESULTS: Forty-seven patients (10 EPS, 12 AVNRT, 13 AFlu, 12 AF) with mean age of 55 ± 13 were included. hsTnT levels increased significantly in all groups after the procedures, while CKMB changed only in the AF group. hsTnT exceeded the reference value in all patients with ablation and in 80% of patients with EPS 4 hours post-ablation. Peak average hsTnT levels for EPS, AVNRT, AFlu were 24 ± 11, 260 ± 218 and 541 ± 233 ng/L, respectively. The highest hsTnT level was measured in the AF group (799 ± 433 ng/L). We found a positive correlation between hsTnT levels and ablation time after RFCA. CONCLUSIONS: The hsTnT levels significantly change after EPS and RFCA, in all patients who underwent ablation, and in 80% of those with EPS had hsTnT positivity in the early post-procedural phase. hsTnT levels depended significantly on the type of the subgroups and correlated with the ablation time. Awareness of those observations is essential to correctly interpret elevated hsTnT levels following RFCA. Orv Hetil. 2019; 160(14): 540-548.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Infarto do Miocárdio/complicações , Adulto , Idoso , Arritmias Cardíacas/sangue , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Biomarcadores/sangue , Ablação por Cateter/métodos , Creatina Quinase Mitocondrial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ablação por Radiofrequência , Resultado do Tratamento , Troponina/sangue
2.
J Am Heart Assoc ; 6(8)2017 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-28751544

RESUMO

BACKGROUND: This study sought to assess payer costs following cryoballoon or radiofrequency current (RFC) catheter ablation of paroxysmal atrial fibrillation in the randomized FIRE AND ICE trial. METHODS AND RESULTS: A trial period analysis of healthcare costs evaluated the impact of ablation modality (cryoballoon versus RFC) on differences in resource use and associated payer costs. Analyses were based on repeat interventions, rehospitalizations, and cardioversions during the trial, with unit costs based on 3 national healthcare systems (Germany [€], the United Kingdom [£], and the United States [$]). Total payer costs were calculated by applying standard unit costs to hospital stays, using International Classification of Diseases, 10th Revision diagnoses and procedure codes that were mapped to country-specific diagnosis-related groups. Patients (N=750) randomized 1:1 to cryoballoon (n=374) or RFC (n=376) ablation were followed for a mean of 1.5 years. Resource use was lower in the cryoballoon than the RFC group (205 hospitalizations and/or interventions in 122 patients versus 268 events in 154 patients). The cost differences per patient in mean total payer costs during follow-up were €640, £364, and $925 in favor of cryoballoon ablation (P=0.012, 0.013, and 0.016, respectively). This resulted in trial period total cost savings of €245 000, £140 000, and $355 000. CONCLUSIONS: When compared with RFC ablation, cryoballoon ablation was associated with a reduction in resource use and payer costs. In all 3 national healthcare systems analyzed, this reduction resulted in substantial trial period cost savings, primarily attributable to fewer repeat ablations and a reduction in cardiovascular rehospitalizations with cryoballoon ablation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Identifier: NCT01490814.


Assuntos
Fibrilação Atrial/economia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/economia , Ablação por Cateter/economia , Criocirurgia/economia , Custos Hospitalares , Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos/economia , Ablação por Cateter/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Cardioversão Elétrica/economia , Europa (Continente) , Humanos , Tempo de Internação/economia , Readmissão do Paciente/economia , Retratamento/economia , Medicina Estatal/economia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA