Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 214: 72-85, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31883465

RESUMO

PURPOSE: Limited information is available on morphologic and functional regeneration of photoreceptors after retinal detachment (RD) surgery. This observational clinical study compared morphologic and functional changes of cones after vitrectomy for macula-off retinal detachment. DESIGN: Prospective, fellow-eye comparative case series. METHODS: StudyPopulation: Five eyes after vitrectomy with gas for macula-off retinal detachment (retinal detachment eyes, RDE) and 5 healthy fellow eyes (HFE) of 5 patients (mean age 59.8 years, macula-off duration 0.5 days to 5.5 days). ObservationProcedures: Eyes were examined with adaptive-optics optical coherence tomography (AO-OCT), spectral-domain OCT (SDOCT), and microperimetry (MP) at 6 (baseline, BL) and 56 weeks (follow-up, FUP) after 23 gauge pars plana vitrectomy and SF6 gas tamponade. Eight corresponding regions at foveal eccentricities of 2.5° (ecc 2.5°) and 6.5° (ecc 6.5°) were analyzed in every eye. AO-OCT en face images and SD-OCT B-scans were graded regarding irregularity and loss of photoreceptor signals ranging from none to severe changes. The number of detectable cones at height of the inner-outer segment junction (IS/OS) and cone outer segment tips (COST) was counted manually in AO-OCT images. MP with a custom grid was used to assess retinal sensitivity at these locations. MainOutcomeMeasures: Cone density, cone pattern regularity and signal attenuation, retinal sensitivity. RESULTS: In comparison to HFE, RDE showed highly irregular cone patterns in AO-OCT and irregular outer retinal bands in SDOCT. Despite significant improvement of cone pattern regularity compared to BL (P < .001), 63% of AO images showed remaining cone pattern irregularity and 45.5% of SDOCT B-scans showed severe signal reduction at FUP. In HFE, mean cone density retrieved from IS/OS and COST remained around 20,000/mm2 (ecc 2.5°) and 16,000/mm2 (ecc 6.5°) at BL and FUP. Cone density of RDE was significantly reduced and ranged between 200/mm2 and 15,600/mm2 (P < .001) at BL. Despite improvement at FUP (P < .001), mean cone density at IS/OS and COST was still lower compared to HFE and ranged between 7790 and 9555 cones/mm2 (P < .001). Mean retinal sensitivity of all measured locations remained 18 dB in HFE and was significantly lower in RDE, with 14.30 dB at BL and 14.64 dB at FUP. Both SDOCT grading and microperimetry sensitivity showed strong correlation with AO-OCT grading and cone density (rho values > 0.750). CONCLUSIONS: The combination of AO-OCT, SDOCT, and microperimetry is a powerful tool to capture cone regeneration after vitreoretinal surgery. Our study shows that cone morphology and function improve within 56 weeks after RD surgery but structural and functional impairment is still present.


Assuntos
Células Fotorreceptoras Retinianas Cones/fisiologia , Descolamento Retiniano/fisiopatologia , Descolamento Retiniano/cirurgia , Tomografia de Coerência Óptica , Testes de Campo Visual , Vitrectomia , Idoso , Comprimento Axial do Olho , Contagem de Células , Tamponamento Interno , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Estudos Prospectivos , Descolamento Retiniano/diagnóstico por imagem , Acuidade Visual/fisiologia , Campos Visuais/fisiologia
2.
J Cataract Refract Surg ; 28(2): 271-5, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11821209

RESUMO

PURPOSE: To develop and evaluate a standardized slitlamp photographic technique to document and quantify anterior capsule opacification (ACO) in the pseudophakic eye. SETTING: University of Vienna, Medical School, Department of Ophthalmology, Vienna, Austria. METHODS: In this prospective study, slitlamp photographs were taken in 29 eyes of 19 patients with ACO of varying degrees and intraocular lenses of different materials. Digital slitlamp photographs were taken by 2 examiners using a standardized protocol. The intensity of anterior fibrosis was evaluated using subjective grading by 2 masked examiners and by image analysis. RESULTS: A standardized protocol was developed for documentation of ACO. The intraexaminer (or short-term) reproducibility (r = 0.96, P < .01) and interexaminer reproducibility (r = 0.93, P < .01) were excellent. The results of image analysis used to objectively quantify ACO correlated with the subjective grading (r = 0.95, P < .01). CONCLUSION: This standardized technique of slitlamp photography and image analysis provided reproducible documentation and can therefore serve as a basis for the quantification of ACO.


Assuntos
Catarata/diagnóstico , Cápsula do Cristalino/patologia , Fotografação/métodos , Complicações Pós-Operatórias/diagnóstico , Câmara Anterior , Fibrose/diagnóstico , Humanos , Processamento de Imagem Assistida por Computador/métodos , Implante de Lente Intraocular , Lentes Intraoculares , Variações Dependentes do Observador , Facoemulsificação , Estudos Prospectivos , Pseudofacia/complicações , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA