Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Endourol ; 37(8): 863-867, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37294208

RESUMO

Introduction: Recent retrospective literature suggests that the quick sequential organ failure assessment (qSOFA) scoring tool is a potentially superior tool over use of the systemic inflammatory response syndrome (SIRS) criteria to predict septic shock after percutaneous nephrolithotomy (PCNL) surgery. Here we examine use of qSOFA and SIRS to predict septic shock within data series collected prospectively on PCNL patients as part of a greater study of infectious complications. Materials and Methods: We performed a secondary analysis of two prospective multicenter studies including PCNL patients across nine institutions. Clinical signs informing SIRS and qSOFA scores were collected no later than postoperative day 1. The primary outcome was sensitivity and specificity of SIRS and qSOFA (high-risk score of greater-or-equal to two points) in predicting admission to the intensive care unit (ICU) for vasopressor support. Results: A total of 218 cases at 9 institutions were analyzed. One patient required vasopressor support in the ICU. The sensitivity/specificity was 100%/72.4% (McNemar's test p < 0.001) for SIRS and was 100%/90.8% (McNemar's test p < 0.001) for qSOFA. Conclusion: Although positive predictive value for both qSOFA and SIRS in prediction of post-PCNL septic shock is low, prospectively collected data demonstrate use of qSOFA may offer greater specificity than SIRS criteria when predicting post-PCNL septic shock.


Assuntos
Nefrolitotomia Percutânea , Sepse , Choque Séptico , Humanos , Choque Séptico/diagnóstico , Choque Séptico/etiologia , Escores de Disfunção Orgânica , Estudos Retrospectivos , Estudos Prospectivos , Prognóstico , Mortalidade Hospitalar , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Curva ROC
2.
J Endourol ; 37(6): 628-633, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36974366

RESUMO

Introduction: To evaluate flexible ureteroscope working channels with a 1.06 mm digital borescope (Clarus Medical, Minneapolis, MN) and identify factors contributing to ureteroscope damage over time. Materials and Methods: We performed a single institutional prospective study of patients undergoing stone surgery using a nondisposable flexible ureteroscope. A 1.06 mm borescope was used to evaluate ureteroscopes before and after surgery. Borescope videos were reviewed by two independent researchers to quantify average pre- and postprocedural damage. Results: Twenty-five procedures were performed with pre- and postprocedural borescope assessment between August 2021 and February 2022. All patients received preoperative CT imaging depicting a mean axial stone size of 14.1 ± 8.4 mm and density of 923.4 ± 458.1 HU. Mean operative time was 63.8 ± 34.0 minutes. The average number an instrument passes through the working channel was 2.1 ± 1.6. Laser was used in 11 cases with mean laser time of 18.8 ± 19.7 minutes and mean total energy of 5.8 ± 4.2 KJ. On preoperative assessment, all ureteroscopes had some form of defect (24% shave, 32% pinhole, 96% dents and scratches, and 28% discolorations). During postoperative assessment, 23/25 (92%) ureteroscopes showed additional damage with an average of 3.7 ± 2.8 imperfections acquired after one use. Significant differences were seen in acquired shavings (p = 0.028) and scratches or dents (p = 0.018). Of the 355 imperfections seen on postoperative evaluation, 0.4% were shave, 3% were pinhole, 85.8% were dents and scratches, and 10.8% were discolorations. Conclusion: The Clarus borescope observed defects after the majority of flexible ureteroscopy procedures for nephrolithiasis. Although such disruptions may not immediately render ureteroscopes nonfunctional, they are more common than previously described and could increase maintenance costs. Further studies are needed to investigate the burden of unit damage per procedure to raise operator awareness and reduce preventable ureteroscope imperfections.


Assuntos
Cálculos Renais , Ureteroscópios , Humanos , Estudos Prospectivos , Ureteroscopia/métodos , Cálculos Renais/cirurgia , Custos e Análise de Custo , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS