Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 13064, 2024 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844596

RESUMO

This study aimed to investigate carbamate pesticide residues in different varieties of date palm fruits in the UAE, utilizing UHPLC-MS/MS. For sample preparation and clean-up, the efficiency and performance of different QuEChERS dispersive solid-phase extraction kits were compared. Precision and recovery were assessed at 10 µg kg-1 for the three kits, revealing that Kit 2 demonstrated the best performance. The selected QuEChERS method was validated to detect 14 carbamate residues in 55 date samples. The method exhibited strong linearity with R2 > 0.999 and low LOD (0.01-0.005 µg kg-1) and LOQ (0.003-0.04 µg kg-1). Excellent accuracy (recovery: 88-106%) and precision (RSD: 1-11%) were observed, with negligible matrix effect (- 4.98-13.26%). All samples contained at least one carbamate residue. While most detected residues were below their MRLs, carbosulfan was found in 21 samples, propoxur in 2 samples, and carbofuran in 1 sample above their MRLs. The hazard index (HI) was calculated for carbosulfan, phenmedipham, carbaryl, propoxur, carbofuran, and methomyl to assess potential health risks for date consumers. All HI values were below the safety limit of 1.0, indicating that the consumption of dates does not pose a non-carcinogenic health risk for adults and children.


Assuntos
Carbamatos , Frutas , Resíduos de Praguicidas , Phoeniceae , Espectrometria de Massas em Tandem , Phoeniceae/química , Resíduos de Praguicidas/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Carbamatos/análise , Frutas/química , Humanos , Medição de Risco , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise
2.
J Dairy Sci ; 107(4): 1916-1927, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37923201

RESUMO

This study aimed to use ultra-high-performance liquid chromatography coupled to a triple-quadrupole mass spectrometer to detect 11 carbamate pesticide residues in raw and pasteurized camel milk samples collected from the United Arab Emirates. A method was developed and validated by evaluating limits of detection, limits of quantitation, linearity, extraction recovery, repeatability, intermediate precision, and matrix effect. Due to the high protein and fat content in camel milk, a sample preparation step was necessary to avoid potential interference during analysis. For this purpose, 5 different liquid-liquid extraction techniques were evaluated to determine their efficiency in extracting carbamate pesticides from camel milk. The established method demonstrated high accuracy and precision. The matrix effect for all carbamate pesticides was observed to fall within the soft range, indicating its negligible effect. Remarkably, detection limits for all carbamates were as low as 0.01 µg/kg. Additionally, the coefficients of determination were >0.998, demonstrating excellent linearity. A total of 17 camel milk samples were analyzed, and only one sample was found to be free from any carbamate residues. The remaining 16 samples contained at least one carbamate residue, yet all detected concentrations were below the recommended maximum residue limits set by Codex Alimentarius and the European Union pesticide databases. Nonetheless, it is worth noting that the detected levels of ethiofencarb in 3 samples were close to the borderline of the maximum residue limit. To assess the health risk for consumers of camel milk, the hazard index values of carbofuran, carbaryl, and propoxur were calculated. The hazard index values for these 3 carbamate pesticides were all below 1, indicating that camel milk consumers are not at risk from these residues.


Assuntos
Resíduos de Praguicidas , Animais , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/veterinária , Camelus , Leite/química , Cromatografia Líquida/métodos , Cromatografia Líquida/veterinária , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/veterinária , Carbamatos/análise , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA