Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Med ; 12(19)2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37834991

RESUMO

Objectives: This article aims to evaluate the accuracy of the color-Doppler-based technique to evaluate residual mitral regurgitation post TEER. Background: The evaluation of residual mitral regurgitation (MR) post-mitral transcutaneous edge-to-edge repair (mitral TEER) is a critical determinant in patients' outcomes. The common methods used today, based on the integration of color flow Doppler parameters, may be misleading because of the multiple jets and high velocities created by the TEER devices. Methods: Patients undergoing TEER at Hadassah hospital were recruited between 2015 and 2019. Post-procedural MR was evaluated using the integrated qualitative approach as recommended by the guidelines. In addition, the MR volume for each patient was calculated by subtracting the forward stroke volume (calculated by multiplying the LVOT area with the velocity time integral of the LVOT systolic flow) from the total stroke volume (calculated by the biplane Simpson method of discs). We compared the two methods for concordance. Results: Overall, 112 cases were enrolled. In 55.4% of cases, the volumetric residual MR was milder than the MR severity assessed by the guidelines' recommended method. In 25.1%, the MR severity was similar in both methods. In 16.2%, the MR severity was worse when calculated using the volumetric method (pValue < 0.001, Kappameasure of agreement = 0.053). The lower residual MR degree using the volumetric approach was mostly observed in patients classified as "moderate" by the integrated approach. Conclusions: MR severity after TEER is often overestimated by the guideline-recommended integrative method when compared with a volumetric method. Alternative methods should be considered to assess the MR severity after mitral TEER.

2.
Eur Heart J Qual Care Clin Outcomes ; 7(5): 447-457, 2021 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-34227670

RESUMO

AIMS: Bicuspid aortic valve (BAV) is the commonest congenital heart valve malformation, and is associated with life-threatening complications. Given the high heritability index of BAV, many experts recommend echocardiography screening for first-degree relatives (FDRs) of an index case. Here, we aim to evaluate the cost-effectiveness of such cascade screening for BAV. METHODS AND RESULTS: Using a decision-analytic model, we performed a cost-effectiveness analysis of echocardiographic screening for FDRs of a BAV index case. Data on BAV probabilities and complications among FDRs were derived from our institution's BAV familial cohort and from the literature on population-based BAV cohorts with long-term follow-up. Health gain was measured as quality-adjusted life years (QALYs). Cost inputs were based on list prices and literature data. One-way and probabilistic sensitivity analyses were performed to account for uncertainty in the model's variables. Screening of FDRs was found to be the dominant strategy, being more effective and less costly than no screening, with savings of €644 and gains of 0.3 QALY. Results were sensitive throughout the range of the main model's variables, including the full range of reported BAV rates among FDRs across the literature. A gradual decrease of the incremental effect was found with the increase in screening age. CONCLUSION: This economic evaluation model found that echocardiographic screening of FDRs of a BAV index case is not only clinically important but also cost-effective and cost-saving. Sensitivity analysis supported the model's robustness, suggesting its generalization.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Análise Custo-Benefício , Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/genética , Humanos
3.
Cardiovasc Revasc Med ; 15(4): 233-4, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24721586

RESUMO

Sudden Cardiac Death--SCD --is a major unmet health problem that needs urgent and prompt solution. AICDs are very expensive, risky and indicated for a small group of patients, at the highest risk. AEDs--Automatic External Defibrillators--are designed for public places and although safe, cannot enter the home-market due to their cost and need for constant, high-cost maintenance. We developed TED, a low-cost AED that derives its energy off the mains, designed for home-use, to save SCD victims' lives.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Serviços de Assistência Domiciliar , Fibrilação Ventricular/terapia , Animais , Morte Súbita Cardíaca/etiologia , Desfibriladores/economia , Cardioversão Elétrica/economia , Eletricidade , Desenho de Equipamento , Custos de Cuidados de Saúde , Humanos , Teste de Materiais , Modelos Animais , Ratos , Fatores de Risco , Suínos , Tempo para o Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia
4.
J Am Soc Echocardiogr ; 23(3): 258-64, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20138473

RESUMO

BACKGROUND: The purpose of this multicenter study was to determine the reliability of visual assessments of segmental wall motion (WM) abnormalities and global left ventricular function among highly experienced echocardiographers using contemporary echocardiographic technology in patients with a variety of cardiac conditions. METHODS: The reliability of visual determinations of left ventricular WM and global function was calculated from assessments made by 12 experienced echocardiographers on 105 echocardiograms recorded using contemporary echocardiographic equipment. Ten studies were reread independently to determine intraobserver reliability. RESULTS: Interobserver reliability for visual differentiation between normal, hypokinetic, and akinetic segments had an intraclass correlation coefficient of 0.70. The intraclass correlation coefficient for dichotomizing segments into normal versus other abnormal was 0.63, for hypokinetic versus other scores was 0.26, and for akinetic versus other scores was 0.58. Similar results were found for intraobserver reliability. Interobserver reliability for WM score index was 0.84 and for left ventricular ejection fraction was 0.78. Similar values were obtained for the intraobserver reliability of WM score index and ejection fraction. Compared to angiographic data, the accuracy of segmental WM assessments was 85%, and correct determination of the culprit artery was achieved in 59% of patients with myocardial infarctions. CONCLUSION: Among experienced readers using contemporary echocardiographic equipment, interobserver and intraobserver reliability was reasonable for the visual quantification of normal and akinetic segments but poor for hypokinetic segments. Reliability was good for the visual assessment of global left ventricular function by WM score index and ejection fraction.


Assuntos
Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Feminino , Humanos , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
5.
Circ Cardiovasc Imaging ; 3(1): 47-53, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19926829

RESUMO

BACKGROUND: Identification and quantification of segmental left ventricular wall motion abnormalities on echocardiograms is of paramount clinical importance but is still performed by a subjective visual method. We constructed an automatic tool for assessment of wall motion based on longitudinal strain. METHODS AND RESULTS: Echocardiograms of 105 patients (3 apical views) were blindly analyzed by 12 experienced readers. Visual segmental scores (VSS) and peak systolic longitudinal strain were assigned to each of 18 segments per patient. Ranges of peak systolic longitudinal strain that best fit VSS (by receiver operating characteristic analysis) were used to generate automatic segmental scores (ASS). Comparisons of ASS and VSS were performed on 1952 analyzable segments. There was agreement of wall motion scores between both methods in 89.6% of normal, 39.5% of hypokinetic, and 69.4% of akinetic segments. Correlation between methods was r=0.63 (P<0.0001). Interobserver and intraobserver reliability using interclass correlation for scoring segmental wall motion into 3 scores by ASS was 0.82 and 0.83 and by VSS 0.70 and 0.69, respectively. Compared with VSS (majority rule), ASS had a sensitivity, specificity, and accuracy of 87%, 85%, and 86%, respectively. ASS and VSS had similar success rates for correct identification of wall motion abnormalities in territories supplied by culprit arteries. VSS had greater specificity and positive predictive values, whereas ASS had higher sensitivity and negative predictive values for identifying the culprit artery. CONCLUSIONS: Automatic quantification of wall motion on echocardiograms by this tool performs as well as visual analysis by experienced echocardiographers, with a greater reliability and similar agreement to angiographic findings.


Assuntos
Automação , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Contração Miocárdica , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Angiografia Coronária , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Ultrassonografia , Disfunção Ventricular Esquerda/fisiopatologia
6.
Am J Med Sci ; 335(6): 457-64, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18552576

RESUMO

BACKGROUND: Octogenarian Israeli prime-minister Ariel Sharon recently sustained a mild, reversible stroke. A patent foramen ovale (PFO) was detected and anticoagulants were given pending PFO closure. A few days later, he sustained major intracerebral hemorrhage and has since remained in vegetative state. The events triggered serious criticism in the mass media, experts promoting one management option over others. Because knowledge of outcome and hindsight bias evaluation of appropriateness of care, we sought to systematically review the clinical case. METHODS: We performed a formal decision analysis to identify the preferred management between anticoagulation, antiplatelets, PFO closure, or no treatment. Using the best evidence available, we built a decision tree. MAIN OUTCOMES: recurrent stroke and treatment complications within 1 year. RESULTS: Optimal decision was found to be critically sensitive to assumptions about etiology, efficacy and safety of treatments, recurrence risk, and to small changes in utilities. In multiway sensitivity analysis, when the risk of recurrent stroke was <0.12 per year, no treatment was the best management. PFO closure is dominant only when the risk of recurrent stroke is >0.12 per year closure effectiveness is assumed to be <0.28. When closure effectiveness is >0.6, it is inferior to anticoagulation and antiplatelet management. CONCLUSIONS: Uncertainties precluded a clear-cut answer and choice was found to be a "toss-up," often associated with much controversy. Use of novel therapies, such as PFO closure, outside clinical trials will not reduce uncertainty about efficacy.


Assuntos
Árvores de Decisões , Forame Oval Patente/complicações , Hemorragias Intracranianas , Ataque Isquêmico Transitório , Modelos Estatísticos , Administração dos Cuidados ao Paciente , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Cateterismo Cardíaco , Forame Oval Patente/cirurgia , Humanos , Hemorragias Intracranianas/etiologia , Hemorragias Intracranianas/prevenção & controle , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/tratamento farmacológico , Administração dos Cuidados ao Paciente/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA