Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Cardiovasc Magn Reson ; 23(1): 92, 2021 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-34247623

RESUMO

AIM: To evaluate the ability of single heartbeat fast-strain encoded (SENC) cardiovascular magnetic resonance (CMR) derived myocardial strain to discriminate between different forms of left ventricular (LV) hypertrophy (LVH). METHODS: 314 patients (228 with hypertensive heart disease (HHD), 45 with hypertrophic cardiomyopathy (HCM), 41 with amyloidosis, 22 competitive athletes, and 33 healthy controls) were systematically analysed. LV ejection fraction (LVEF), LV mass index and interventricular septal (IVS) thickness, T1 mapping and atypical late gadolinium enhancement (LGE) were assessed. In addition, the percentage of LV myocardial segments with strain ≤ - 17% (%normal myocardium) was determined. RESULTS: Patients with amyloidosis and HCM exhibited the highest IVS thickness (17.4 ± 3.3 mm and 17.4 ± 6 mm, respectively, p < 0.05 vs. all other groups), whereas patients with amyloidosis showed the highest LV mass index (95.1 ± 20.1 g/m2, p < 0.05 vs all others) and lower LVEF compared to controls (50.5 ± 9.8% vs 59.2 ± 5.5%, p < 0.05). Analysing subjects with mild to moderate hypertrophy (IVS 11-15 mm), %normal myocardium exhibited excellent and high precision, respectively for the differentiation between athletes vs. HCM (sensitivity and specificity = 100%, Area under the curve; AUC%normalmyocardium = 1.0, 95%CI = 0.85-1.0) and athletes vs. HHD (sensitivity = 83%, specificity = 75%, AUC%normalmyocardium = 0.85, 95%CI = 0.78-0.90). Combining %normal myocardial strain with atypical LGE provided high accuracy also for the differentiation of HHD vs. HCM (sensitivity = 82%, specificity = 100%, AUCcombination = 0.92, 95%CI = 0.88-0.95) and HCM vs. amyloidosis (sensitivity = 83%, specificity = 100%, AUCcombination = 0.83, 95%CI = 0.60-0.96). CONCLUSION: Fast-SENC derived myocardial strain is a valuable tool for differentiating between athletes vs. HCM and athletes vs. HHD. Combining strain and LGE data is useful for differentiating between HHD vs. HCM and HCM vs. cardiac amyloidosis.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
2.
ESC Heart Fail ; 6(4): 584-602, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31021534

RESUMO

This study aims to assess the usefulness of strain-encoded magnetic resonance (SENC) for the quantification of myocardial deformation ('strain') in healthy volunteers and for the diagnostic workup of patients with different cardiovascular pathologies. SENC was initially described in the year 2001. Since then, the SENC sequence has undergone several technical developments, aiming at the detection of strain during single-heartbeat acquisitions (fast-SENC). Experimental and clinical studies that used SENC and fast-SENC or compared SENC with conventional cine or tagged magnetic resonance in phantoms, animals, healthy volunteers, or patients were systematically searched for in PubMed. Using 'strain-encoded magnetic resonance and SENC' as keywords, three phantom and three animal studies were identified, along with 27 further clinical studies, involving 185 healthy subjects and 904 patients. SENC (i) enabled reproducible assessment of myocardial deformation in vitro, in animals and in healthy volunteers, (ii) showed high reproducibility and substantially lower time spent compared with conventional tagging, (iii) exhibited incremental value to standard cine imaging for the detection of inducible ischaemia and for the risk stratification of patients with ischaemic heart disease, and (iv) enabled the diagnostic classification of patients with transplant vasculopathy, cardiomyopathies, pulmonary hypertension, and diabetic heart disease. SENC has the potential to detect a wide range of myocardial diseases early, accurately, and without the need of contrast agent injection, possibly enabling the initiation of specific cardiac therapies during earlier disease stages. Its one-heartbeat acquisition mode during free breathing results in shorter cardiovascular magnetic resonance protocols, making its implementation in the clinical realm promising.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Animais , Humanos
3.
Sci Rep ; 8(1): 14100, 2018 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-30237411

RESUMO

Myocardial strain is a well validated parameter for estimating left ventricular (LV) performance. The aim of our study was to evaluate the inter-study as well as intra- and interobserver reproducibility of fast-SENC derived myocardial strain. Eighteen subjects (11 healthy individuals and 7 patients with heart failure) underwent a cardiac MRI examination including fast-SENC acquisition for evaluating left ventricular global longitudinal (GLS) and circumferential strain (GCS) as well as left ventricular ejection fraction (LVEF). The examination was repeated after 63 [range 49‒87] days and analyzed by two experienced observers. Ten datasets were repeatedly assessed after 1 month by the same observer to test intraobserver variability. The reproducibility was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Patients with heart failure demonstrated reduced GLS and GCS compared to healthy controls (-15.7 ± 3.7 vs. -20.1 ± 1.4; p = 0.002 for GLS and -15.3 ± 3.7 vs. -21.4 ± 1.1; p = 0.001 for GCS). The test-retest analysis showed excellent ICC for LVEF (0.92), GLS (0.94) and GCS (0.95). GLS exhibited excellent ICC (0.99) in both intra- and interobserver variability analysis with very narrow limits of agreement (-0.6 to 0.5 for intraobserver and -1.3 to 0.96 for interobserver agreement). Similarly, GCS showed excellent ICC (0.99) in both variability analyses with narrow limits of agreement (-1.1 to 1.2 for intraobserver and -1.7 to 1.3 for interobserver agreement), whereas LVEF showed larger limits of agreement (-14.4 to 10.1). The analysis of fast-SENC derived myocardial strain using cardiac MRI provides a highly reproducible method for assessing LV functional performance.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
4.
J Cardiovasc Magn Reson ; 17: 69, 2015 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-26253220

RESUMO

BACKGROUND: Assessment of longitudinal function with cardiovascular magnetic resonance (CMR) is limited to measurement of systolic excursion of the mitral annulus (MAPSE) or elaborate strain imaging modalities. The aim of this study was to develop a fast assessable parameter for the measurement of long axis strain (LAS) with CMR. METHODS: 40 healthy volunteers and 125 patients with different forms of cardiomyopathy were retrospectively analyzed. Four different approaches for the assessment of LAS with CMR measuring the distance between the LV apex and a line connecting the origins of the mitral valve leaflets in enddiastole and endsystole were evaluated. Values for LAS were calculated according to the strain formula. RESULTS: LAS derived from the distance of the epicardial apical border to the midpoint of the line connecting the mitral valve insertion points (LAS-epi/mid) proved to be the most reliable parameter for the assessment of LAS among the different approaches. LAS-epi/mid displayed the highest sensitivity (81.6 %) and specificity (97.5 %), furthermore showing the best correlation with feature tracking (FTI) derived transmural longitudinal strain (r = 0.85). Moreover, LAS-epi/mid was non-inferior to FTI in discriminating controls from patients (Area under the curve (AUC) = 0.95 vs. 0.94, p = NS). The time required for analysis of LAS-epi/mid was significantly shorter than for FTI (67 ± 8 s vs. 180 ± 14 s, p < 0.0001). Additionally, LAS-epi/mid performed significantly better than MAPSE (Delta AUC = 0.09; p < 0.005) and the ejection fraction (Delta AUC = 0.11; p = 0.0002). Reference values were derived from 234 selected healthy volunteers. Mean value for LAS-epi/mid was -17.1 ± 2.3 %. Mean values for men were significantly lower compared to women (-16.5 ± 2.2 vs. -17.9 ± 2.1 %; p < 0.0001), while LAS decreased with age. CONCLUSIONS: LAS-epi/mid is a novel and fast assessable parameter for the analysis of global longitudinal function with non-inferiority compared to transmural longitudinal strain.


Assuntos
Cardiomiopatias/diagnóstico , Interpretação de Imagem Assistida por Computador/normas , Imagem Cinética por Ressonância Magnética/normas , Contração Miocárdica , Função Ventricular Esquerda , Adulto , Fatores Etários , Área Sob a Curva , Fenômenos Biomecânicos , Cardiomiopatias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores Sexuais , Estresse Mecânico , Fatores de Tempo
5.
Clin Res Cardiol ; 104(7): 591-602, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25643953

RESUMO

BACKGROUND: Myocardial deformation measurement is superior to left ventricular ejection fraction in identifying early changes in myocardial contractility and prediction of cardiovascular outcome. The lack of standardization hinders its clinical implementation. The aim of the study is to investigate a novel standardized deformation imaging approach based on the feature tracking algorithm for the assessment of global longitudinal (GLS) and global circumferential strain (GCS) in echocardiography and cardiac magnetic resonance imaging (CMR). METHODS: 70 subjects undergoing CMR were consecutively investigated with echocardiography within a median time of 30 min. GLS and GCS were analyzed with a post-processing software incorporating the same standardized algorithm for both modalities. Global strain was defined as the relative shortening of the whole endocardial contour length and calculated according to the strain formula. RESULTS: Mean GLS values were -16.2 ± 5.3 and -17.3 ± 5.3 % for echocardiography and CMR, respectively. GLS did not differ significantly between the two imaging modalities, which showed strong correlation (r = 0.86), a small bias (-1.1 %) and narrow 95 % limits of agreement (LOA ± 5.4 %). Mean GCS values were -17.9 ± 6.3 and -24.4 ± 7.8 % for echocardiography and CMR, respectively. GCS was significantly underestimated by echocardiography (p < 0.001). A weaker correlation (r = 0.73), a higher bias (-6.5 %) and wider LOA (± 10.5 %) were observed for GCS. GLS showed a strong correlation (r = 0.92) when image quality was good, while correlation dropped to r = 0.82 with poor acoustic windows in echocardiography. GCS assessment revealed only a strong correlation (r = 0.87) when echocardiographic image quality was good. No significant differences for GLS between two different echocardiographic vendors could be detected. CONCLUSIONS: Quantitative assessment of GLS using a standardized software algorithm allows the direct comparison of values acquired irrespective of the imaging modality. GLS may, therefore, serve as a reliable parameter for the assessment of global left ventricular function in clinical routine besides standard evaluation of the ejection fraction.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Software , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Força Compressiva , Ecocardiografia/métodos , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico , Volume Sistólico , Resistência à Tração
6.
Acta Cardiol ; 65(1): 67-77, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20306892

RESUMO

Right ventricular function is acknowledged as an important prognostic element in cardiovascular pathologies. Although recent years have seen significant advances in the exploration of cardiac function, assessing right ventricular performance still remains a challenge for the daily practice. The right ventricle is a complex structure that cannot be approximated by a simple geometric form. It functions in a low impedance system therefore it is sensitive to pressure overload. Along with contractility and loading conditions, ventricular interactions play an important part in right ventricular function and failure. The aims of our review are to describe the main characteristics of RV anatomy, function and failure and also to present the standard and novel tools that can be employed to investigate them. Moreover, the advantages, limitations and clinical significance of each parameter will be discussed.


Assuntos
Ventrículos do Coração/anatomia & histologia , Função Ventricular Direita/fisiologia , Humanos , Imageamento por Ressonância Magnética , Recuperação de Função Fisiológica/fisiologia , Fatores de Risco , Ultrassonografia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/patologia , Disfunção Ventricular Direita/fisiopatologia
7.
J Am Soc Echocardiogr ; 23(3): 301-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20138468

RESUMO

BACKGROUND: The aim of this study was to assess speckle tracking-derived fetal cardiac function in a normal population and in recipient fetuses of twin-to-twin transfusion syndrome (TTTS). METHODS: A case-control study was conducted of 59 uncomplicated singleton pregnancies and 17 recipient fetuses of TTTS. Peak systolic strain, strain rate, velocity, and displacement were calculated, corrected for gestational age, and compared between patients with TTTS and controls. RESULTS: The feasibility of speckle tracking was 83% in controls but only 61% in patients with TTTS. Myocardial velocity and displacement increased over gestation, and regional differences were present within each wall and between walls. Strain and strain rate were stable within each wall but were higher in the right ventricle than in the left ventricle and septum. Right ventricular strain was decreased in patients with TTTS compared with controls (0.75+/-0.34 vs 1.00+/-0.37 multiples of the median, P=.04). CONCLUSION: The feasibility of speckle tracking is low when imaging conditions are challenging, but it can identify right ventricular failure in selected patients with TTTS.


Assuntos
Ecocardiografia/métodos , Transfusão Feto-Fetal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Pré-Natal/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
8.
Eur J Echocardiogr ; 11(2): 81-96, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20124362

RESUMO

For many years, the echocardiographic quantitative assessment of right ventricular (RV) function has been difficult owing to the complex RV anatomy. Identifying an accurate and reliable echocardiographic parameter for the functional assessment of the RV still remains a challenge. The review presents a summary of the most studied and presently used parameters of RV function, with their reported normal values, as well as advantages and limitations of use. Combinations of these parameters are used in daily clinical practice, each one offering only partial information about the status of the RV. Myocardial velocity and strain rate imaging have promising results in the assessment of RV function. There is hope that novel myocardial deformation parameters and three-dimensional echocardiography-derived parameters may add value to the examination of the RV, but validation studies are still needed.


Assuntos
Ecocardiografia Doppler , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita , Diástole , Estudos de Viabilidade , Humanos , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA