Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chemosphere ; 125: 25-32, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25655442

RESUMO

The removal and transformation of 15 common fragrance allergens and two polycyclic musks in water samples were studied using UV irradiation and chlorination treatments. The monitoring of the reaction was carried out by a HS-SPME method coupled to GC-MS analysis. Different behaviours were observed depending on the compound and the treatment applied. Elimination experiments showed that all target compounds were affected by at least one of the two treatments. A total of 15 UV transformation products were detected and chemical structures were proposed for five of them. In the chlorination experiments, only galaxolide and benzyl cinnamate transformation products were observed.


Assuntos
Halogenação , Perfumes/química , Raios Ultravioleta , Poluentes Químicos da Água/química , Purificação da Água/métodos , Ácidos Graxos Monoinsaturados/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos
2.
Environ Sci Technol ; 44(21): 8289-94, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20919722

RESUMO

Contamination by environmental tobacco smoke (ETS) on premises where smoking is permitted is evaluated. Although all target VOCs evaluated show significant differences between smoking and nonsmoking indoors, the results obtained indicate that 2,5-dimethylfuran is the most appropriate and effective marker of ETS contamination given that this compound is only detected in environments where people have smoked and so the detection of this compound cannot be attributed to other contamination sources such as traffic. Moreover, the air levels of this compound due to coffee aroma are below the detection limits for this methodology. A preliminary study is performed to evaluate whether 2,5-dimethylfuran, a smoking breath biomarker, can be detected in passive smokers working in smoking environments. The compound was continuously detected in the breath of nonsmoking employees after being in direct contact with ETS for just a few hours. The Tedlar gas sampling bags had 5% loss of 2,5-dimethylfuran after 3 h of storage, which we took as the maximum recommended period for air sample storage.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental , Furanos/análise , Logradouros Públicos , Poluição por Fumaça de Tabaco/análise , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Biomarcadores/análise , Testes Respiratórios , Exposição Ambiental , Estações do Ano , Poluição por Fumaça de Tabaco/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA