Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Neuroradiol ; 33(4): 1075-1086, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37368089

RESUMO

PURPOSE: Information about the cost-effectiveness of a certain treatment is relevant for decision-making and healthcare providers. This study compares the cost-effectiveness of the novel Woven Endobridge (WEB) for intracranial aneurysm treatment with conventional coiling and stent-assisted coiling (SAC) from the perspective of the German Statutory Health Insurance. METHODS: A patient-level simulation was constructed to simulate 55-year-old patients with an unruptured middle cerebral artery aneurysm (size: 3-11 mm) considering WEB treatment, coiling or SAC in terms of morbidity, angiographic outcome, retreatment, procedural and rehabilitation costs and rupture rates. Incremental cost-effectiveness ratios (ICERs) were calculated as costs per quality-adjusted life years (QALYs) and costs per year with neurologic morbidity avoided. Uncertainty was explored with deterministic and probabilistic sensitivity analyses. The majority of data were obtained from prospective multi-center studies and meta-analyses of non-randomized studies. RESULTS: In the base case, lifetime QALYs were 13.24 for the WEB, 12.92 for SAC and 12.68 for coiling. Lifetime costs were 20,440 € for the WEB, 23,167 € for SAC, and 8200 € for coiling. Compared to coiling, the ICER for the WEB was 21,826 €/QALY, while SAC was absolutely dominated by WEB. Probabilistic sensitivity analysis revealed that at a willingness-to-pay of ≥ 30,000 €/QALY, WEB was the preferred treatment. Deterministic sampling showed that the discount rate, material costs and retreatment rates had the largest impact on the ICERs. CONCLUSION: The novel WEB showed at least comparable cost-effectiveness to SAC for treatment of broad-based unruptured aneurysms. Considering all three modalities, coiling had the least costs; however this modality is often not appropriate for the treatment of wide-necked aneurysms.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Pessoa de Meia-Idade , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Análise Custo-Benefício , Estudos Prospectivos , Resultado do Tratamento , Stents , Estudos Retrospectivos
2.
Neuroradiology ; 65(4): 765-773, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36460785

RESUMO

PURPOSE: Endovascular coil occlusion represents the standard treatment for basilar tip aneurysms. Recently, this role has been rivalled by intrasaccular flow disruptors across numerous centres. We retrospectively compared WEB embolization and coiling for the treatment of ruptured basilar tip aneurysms. METHODS: Patients treated with WEB or coiling at four neurovascular centres were reviewed. Procedure-related complications, clinical outcome, and angiographic results were retrospectively compared. RESULTS: The study included 23 patients treated with the WEB (aneurysm size: 6.6 ± 1.9 mm) and 56 by coiling (aneurysm size: 6.7 ± 2.5 mm). Stent-assistance was more often necessary with coiling than with WEB embolization (32% vs. 4%, p = 0.009). A modified Rankin scale score ≤ 2 at discharge had 21 (37.5%) patients in the coiling group and 12 (52.2%) in the WEB group (p = 0.235). Immediate complete and adequate occlusion rates were 52% for the WEB and 87% for coiling. At short-term follow-up, these rates were 87% for the WEB and 72% for coiling, respectively. There was no delayed aneurysm re-bleeding during follow-up. CONCLUSION: Both coiling and WEB seem to prevent rebleeding in ruptured BTA aneurysms. WEB embolization required less frequently stent-support than coiling, potentially advantageous for SAH patients to avoid anti-platelet therapy in the light of concomitant procedures like ventricular drainage.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Correção Endovascular de Aneurisma , Aneurisma Intracraniano , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/cirurgia , Aneurisma Roto/cirurgia , Correção Endovascular de Aneurisma/efeitos adversos , Correção Endovascular de Aneurisma/métodos , Estudos Retrospectivos , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/prevenção & controle
3.
Quant Imaging Med Surg ; 12(7): 3640-3654, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35782261

RESUMO

Background: In stroke magnetic resonance imaging (MRI), contrast-enhanced magnetic resonance angiography (CE-MRA) is the clinical standard to depict extracranial arteries but native MRA techniques are of increased interest to facilitate clinical practice. The purpose of this study was to assess the detection of extracranial internal carotid artery (ICA) stenosis and plaques as well as the image quality of cervical carotid arteries between a novel flow-independent relaxation-enhanced angiography without contrast and triggering (REACT) sequence and CE-MRA in acute ischemic stroke (AIS). Methods: In this retrospective, single-center study, 105 consecutive patients (65.27±18.74 years, 63 males) were included, who received a standard stroke protocol at 3T in clinical routine including Compressed SENSE (CS) accelerated (factor 4) 3D isotropic REACT (fixed scan time: 02:46 min) and CS accelerated (factor 6) 3D isotropic CE-MRA. Three radiologists independently assessed scans for the presence of extracranial ICA stenosis and plaques (including hyper-/hypointense signal) with concomitant diagnostic confidence using 3-point scales (3= excellent). Vessel quality, artifacts, and image noise of extracranial carotid arteries were subjectively scored on 5-point scales (5= excellent/none). Wilcoxon tests were used for statistical comparison. Results: Considering CE-MRA as the standard of reference, REACT provided a sensitivity of 89.8% and specificity of 95.2% for any and of 93.5% and 95.8% for clinically relevant (≥50%) extracranial ICA stenosis and yielded a to CE-MRA comparable diagnostic confidence [mean ± standard deviation (SD), median (interquartile range): 2.8±0.5, 3 (3-3) vs. 2.7±0.5, 3 (2-3), P=0.03]. Using REACT, readers detected more plaques overall (n=57.3 vs. 47.7, P<0.001) and plaques of hyperintense signal (n=12.3 vs. 5.7, P=0.02) with higher diagnostic confidence [2.8±0.5, 3 (3-3) vs. 2.6±0.7, 3 (2-3), P<0.001] than CE-MRA. After analyzing a total of 1,260 segments, the vessel quality of all segments combined [4.61±0.66 vs. 4.58±0.68, 5 (4-5) vs. 5 (4-5), P=0.0299] and artifacts [4.51±0.70 vs. 4.44±0.73, 5 (4-5) vs. 5 (4-5), P>0.05] were comparable between the sequences with REACT showing a lower image noise [4.43±0.67 vs. 4.25±0.71, 5 (4-5) vs. 4 (4-5), P<0.001]. Conclusions: Without the use of gadolinium-based contrast agents or triggering, REACT provides a high sensitivity and specificity for extracranial ICA stenosis and a potential improved depiction of adjacent plaques while yielding to CE-MRA comparable vessel quality in a large patient cohort with AIS.

4.
Phys Med Biol ; 60(15): 5891-909, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26184743

RESUMO

The purpose of this study is to investigate feasibility of a novel real-time dosimetry method for fluoroscopically guided interventions utilizing thin-film detector arrays in several potential locations with respect to the patient and x-ray equipment. We employed Monte Carlo (MC) simulation to establish the fluoroscopic beam model to determine dosimetric quantities directly from measured doses in thin-film detector arrays at three positions: A-attached to the x-ray source, B-on the couch under the patient and C-attached to the fluoroscopic imager. Next, we developed a calibration method to determine skin dose at the entry of the beam ([Formula: see text]) as well as the dose distribution along each ray of the beam in a water-equivalent patient model. We utilized the concept of water-equivalent thickness to determine the dose inside the patient based on doses measured outside of the patient by the thin-film detector array layers: (a) A, (b) B, or (c) B and C. In the process of calibration we determined a correction factor that characterizes the material-specific response of the detector, backscatter factor and attenuation factor for slab water phantoms of various thicknesses. Application of this method to an anthropomorphic phantom showed accuracy of about 1% for [Formula: see text] and up to about 10% for integral dose along the beam path when compared to a direct simulation of dose by MC.


Assuntos
Dosimetria Fotográfica/métodos , Fluoroscopia/métodos , Humanos , Método de Monte Carlo , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA