Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
JACC Cardiovasc Interv ; 10(10): 999-1007, 2017 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-28521932

RESUMO

OBJECTIVES: The aim of this study was to investigate the epicardial and microvascular substrates associated with discordances between fractional flow reserve (FFR) and coronary flow reserve (CFR) values. BACKGROUND: Discordances between FFR and CFR remain poorly characterized. METHODS: FFR, hyperemic stenosis resistance (HSR), and intravascular ultrasound were performed as indexes of epicardial function and CFR and hyperemic microvascular resistance (HMR) as measures of microvascular function in 94 patients with moderate coronary stenosis. Maximal plaque burden (PBmax), HSR, and HMR were calculated in 4 quadrants based on values of FFR ≤0.80 and CFR ≤2.0 as follows: concordant normal (preserved FFR and CFR), concordant abnormal (low FFR and CFR), discordant low FFR and preserved CFR, and discordant preserved FFR and low CFR. RESULTS: Sixty-four patients (68%) had concordant FFR and CFR findings, and 30 patients (32%) had discordant FFR and CFR. Compared with patients with preserved FFR and CFR, those with low FFR and CFR had higher PBmax (p = 0.003), higher HSR (p < 0.001), and similar HMR. Among patients with preserved FFR, those with reduced CFR had similar PBmax and HSR but a trend toward higher HMR (p = 0.058) compared with patients with preserved CFR. Among patients with reduced FFR, those with preserved CFR had lower PBmax (p = 0.004), a trend toward lower HSR (p = 0.065), and lower HMR (p = 0.03) compared with patients with reduced CFR. Furthermore, compared with patients with preserved FFR and low CFR, those with low FFR and preserved CFR had higher HSR (p = 0.022) but lower HMR (p = 0.003). CONCLUSIONS: In patients with moderate coronary stenosis, preserved FFR and low CFR is associated with increased microvascular resistance, while low FFR and preserved CFR has modest epicardial stenosis and preserved microvascular function.


Assuntos
Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Ultrassonografia de Intervenção , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Ecocardiografia Doppler , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Microcirculação , Pessoa de Meia-Idade , Placa Aterosclerótica , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Resistência Vascular , Vasodilatadores/administração & dosagem
2.
JACC Cardiovasc Interv ; 9(7): 728-41, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27056313

RESUMO

OBJECTIVES: The purpose of this study was to assess and compare in vivo the restoration of vasomotor function following Absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, California) and metallic Xience V (XV) (Abbott Vascular, Santa Clara, California) stent implantations in porcine coronary arteries at 1 and 2 years. BACKGROUND: Drug-eluting metallic coronary stents induce sustained vasomotor dysfunction, and preliminary observations from arteries with bioresorbable scaffolds have indicated partially restored vasoreactivity. METHODS: A total of 15 Absorb BVS (3.0 × 18.0 mm) and 14 XV (3.0 × 18.0 mm or 3.0 × 12.0 mm) stents were randomly implanted in the main coronaries of 12 nonatherosclerotic swine. The effect of implant on vasomotor performance (constrictive and expansive) was measured in the stented/scaffolded segments and the 5-mm proximal and distal adjacent segments in vivo by angiography assessing mean luminal diameter changes following infusion of vasoactive agents at 1 year (n = 6) and 2 years (n = 6) as well as ex vivo at 2 years using a tissue chamber apparatus. Endothelial cell function and smooth muscle cell phenotype gene marker levels were evaluated with quantitative real-time polymerase chain reaction. RESULTS: The scaffolded Absorb BVS segments showed fully restored constrictive response compared with XV implanted vessels at 1 year: -24.30 ± 14.31% versus -1.79 ± 6.57% (p < 0.004) and at 2 years: -28.13 ± 14.60% versus -3.90 ± 6.44% (p < 0.004). The early restoration of vasomotor function within the scaffolded segments reached a peak at 1 year and did not significantly change up to 2 years. The vasoactive responses of Absorb BVS-implanted vessels within the scaffolded segments were similar to those observed within the proximal and distal edge segments at both time points. Conversely, the stented XV segments demonstrated significantly impaired constrictive response compared with the distal XV edges at 1 year: -1.79 ± 6.57% versus -21.89 ± 7.17% (p < 0.0002) and at 2 years: -3.90 ± 6.44% versus -21.93 ± 15.60% (p < 0.03). Ex vivo assessment of contraction induced by PGF2α and relaxation induced by substance P of isolated BVS segments compared with XV-treated segments generated greater contraction force of 3.94 ± 0.97 g versus 1.83 ± 1.03 g (p < 0.05), and endothelial-dependent relaxation reached 35.91 ± 24.74% versus 1.20 ± 3.79% (p < 0.01). Quantitative real-time polymerase chain reaction gene analysis at 2 years demonstrated increased Connexin 43 messenger ribonucleic acid levels of Absorb BVS-treated vessels compared with XV-treated vessels: 1.92 ± 0.23 versus 0.77 ± 12 (p < 0.05). CONCLUSIONS: Absorb BVS-implanted coronary arteries demonstrate early functional restoration of the scaffolded and adjacent segments at 1 year, which is preserved up to 2 years.


Assuntos
Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Intervenção Coronária Percutânea/instrumentação , Vasoconstrição/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Animais , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/metabolismo , Vasos Coronários/fisiopatologia , Regulação da Expressão Gênica , Técnicas In Vitro , Modelos Animais , Intervenção Coronária Percutânea/efeitos adversos , Fenótipo , Reação em Cadeia da Polimerase em Tempo Real , Recuperação de Função Fisiológica , Suínos , Porco Miniatura , Fatores de Tempo
4.
J Am Heart Assoc ; 5(1)2016 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-26811165

RESUMO

BACKGROUND: We hypothesized that nebivolol, a ß-blocker with nitric oxide-mediated activity, compared with atenolol, a ß-blocker without such activity, would decrease oxidative stress and improve the effects of endothelial dysfunction and wall shear stress (WSS), thereby reducing atherosclerosis progression and vulnerability in patients with nonobstructive coronary artery disease. METHODS AND RESULTS: In this pilot double-blinded randomized controlled trial, 24 patients treated for 1 year with nebivolol 10 mg versus atenolol 100 mg plus standard medical therapy underwent baseline and follow-up coronary angiography with assessments of inflammatory and oxidative stress biomarkers, microvascular function, endothelial function, and virtual histology intravascular ultrasound. WSS was calculated from computational fluid dynamics. Virtual histology intravascular ultrasound segments were assessed for vessel volumetrics and remodeling. There was a trend toward more low-WSS segments in the nebivolol cohort (P=0.06). Low-WSS regions were associated with greater plaque progression (P<0.0001) and constrictive remodeling (P=0.04); conversely, high-WSS segments demonstrated plaque regression and excessive expansive remodeling. Nebivolol patients had decreased lumen and vessel areas along with increased plaque area, resulting in more constrictive remodeling (P=0.002). There were no significant differences in biomarker levels, microvascular function, endothelial function, or number of thin-capped fibroatheromas per vessel. Importantly, after adjusting for ß-blocker, low-WSS segments remained significantly associated with lumen loss and plaque progression. CONCLUSION: Nebivolol, compared with atenolol, was associated with greater plaque progression and constrictive remodeling, likely driven by more low-WSS segments in the nebivolol arm. Both ß-blockers had similar effects on oxidative stress, microvascular function, and endothelial function. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/. Unique identifier: NCT01230892.


Assuntos
Agonistas de Receptores Adrenérgicos beta 3/uso terapêutico , Antagonistas Adrenérgicos beta/uso terapêutico , Atenolol/uso terapêutico , Doença da Artéria Coronariana/tratamento farmacológico , Circulação Coronária/efeitos dos fármacos , Vasos Coronários/efeitos dos fármacos , Diagnóstico por Imagem , Nebivolol/uso terapêutico , Placa Aterosclerótica , Adulto , Biomarcadores/sangue , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Diagnóstico por Imagem/métodos , Método Duplo-Cego , Ecocardiografia Doppler , Feminino , Georgia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Oxidativo/efeitos dos fármacos , Projetos Piloto , Valor Preditivo dos Testes , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Remodelação Vascular/efeitos dos fármacos
5.
Cardiovasc Ultrasound ; 11: 25, 2013 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-23870248

RESUMO

PURPOSE: To evaluate the atherosclerotic evolution in coronary bifurcations located proximally and distally to a bioresorbable scaffold. METHODS: Thirty bifurcations located >5 mm beyond the scaffolded segment, being investigated with serial intravascular ultrasound virtual histology (IVUS-VH) examinations, at baseline and 2-years, in patients enrolled in the ABSORB cohort B1 study were included in this analysis. In each bifurcation, the frames portraying the proximal rim, in-bifurcation, and distal rim of the ostium of the side branch were analyzed. The geometric parameters and plaque types were evaluated at baseline and 2-years follow-up. RESULTS: There were no significant differences in the geometrical parameters such as lumen, vessel and plaque areas as well as in the composition of the atheroma between baseline and 2-years follow-up.When we separately examined the bifurcations located proximally and distally to the scaffolded segment, no changes were found at the distal bifurcations, while at the proximal bifurcations there was a statistical significant decrease in the plaque burden (36.67 ± 13.33% at baseline vs. 35.06 ± 13.20% at 2 years follow-up, p = 0.04).Ten necrotic core rich plaques were found at baseline, of which 2 regressed to either fibrotic plaque or to intimal thickening at 2 years follow-up. The other 8 did not change. Disease progression was noted in 3 plaques (1 adaptive intimal thickening, 1 fibrotic and 1 fibrocalcific plaque) that evolved to necrotic rich plaques. CONCLUSIONS: Plaque regression was noted at the bifurcations located proximally to the bioresorbable scaffold but not at these located distally. Additional studies are required to confirm this finding and examine further the effect of drug elution on atherosclerotic evolution.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Ecocardiografia/métodos , Sirolimo/análogos & derivados , Ultrassonografia de Intervenção/métodos , Idoso , Estenose Coronária , Everolimo , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imunossupressores/administração & dosagem , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sirolimo/administração & dosagem , Técnica de Subtração , Resultado do Tratamento , Interface Usuário-Computador
7.
EuroIntervention ; 9(6): 709-20, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23628499

RESUMO

AIMS: To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS: Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS: The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.


Assuntos
Stents Farmacológicos , Everolimo , Implantes Absorvíveis , Seguimentos , Humanos , Masculino , Sirolimo/administração & dosagem , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 5(6): 656-65, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22721662

RESUMO

OBJECTIVES: This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS). BACKGROUND: The edge vascular response after implantation of the BVS has not been previously investigated. METHODS: The ABSORB Cohort B trial enrolled 101 patients and was divided into B(1) (n = 45) and B(2) (n = 56) subgroups. The adjacent (5-mm) proximal and distal vessel segments to the implanted ABSORB BVS were investigated at either 6 months (B(1)) or 1 year (B(2)) with virtual histology intravascular ultrasound (VH-IVUS) imaging. RESULTS: At the 5-mm proximal edge, the only significant change was modest constrictive remodeling at 6 months (Δ vessel cross-sectional area: -1.80% [-3.18; 1.30], p < 0.05), with a tendency to regress at 1 year (Δ vessel cross-sectional area: -1.53% [-7.74; 2.48], p = 0.06). The relative change of the fibrotic and fibrofatty (FF) tissue areas at this segment were not statistically significant at either time point. At the 5-mm distal edge, a significant increase in the FF tissue of 43.32% [-19.90; 244.28], (p < 0.05) 1-year post-implantation was evident. The changes in dense calcium need to be interpreted with caution since the polymeric struts are detected as "pseudo" dense calcium structures with the VH-IVUS imaging modality. CONCLUSIONS: The vascular response up to 1 year after implantation of the ABSORB BVS demonstrated some degree of proximal edge constrictive remodeling and distal edge increase in FF tissue resulting in nonsignificant plaque progression with adaptive expansive remodeling. This morphological and tissue composition behavior appears to not significantly differ from the behavior of metallic drug-eluting stents at the same observational time points.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Sirolimo/análogos & derivados , Alicerces Teciduais , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Vasos Coronários/patologia , Everolimo , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem
9.
Int J Cardiovasc Imaging ; 27(2): 225-37, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21373888

RESUMO

Cardiovascular disease remains the leading cause of mortality, morbidity and disability in the developed world, predominantly affecting the adult population. In the early 1990s coronary heart disease (CHD) was established as affecting one in two men and one in three women by the age of forty. Despite the dramatic progress in the field of cardiovascular medicine in terms of diagnosis and treatment of heart disease, modest improvements have only been achieved when the reduction of cardiovascular mortality and morbidity indices are assessed. To better understand coronary atherosclerosis, new imaging modalities have been introduced. These novel imaging modalities have been used in two ways: (1) for the characterization of plaque types; (2) for the assessment of the progression and regression of tissue types. These two aspects will be discussed in this review.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Ultrassonografia de Intervenção , Adulto , Doença da Artéria Coronariana/terapia , Progressão da Doença , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Prognóstico , Ruptura Espontânea , Índice de Gravidade de Doença
10.
Eur Heart J ; 32(3): 294-304, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21123276

RESUMO

AIMS: The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT). METHODS AND RESULTS: A total of 12 lesions treated with the BVS 1.0 and 12 selected lesions treated with the revised BVS 1.1 were imaged at baseline and 6-month follow-up with OCT. Late shrinkage and neointimal area (NIA) were derived from OCT area measurements. Neointimal thickness was measured in each strut. Strut appearance has been classified as previously described. Baseline clinical, angiographic, and OCT characteristics were mainly similar in the two groups. At 6 months, absolute and relative shrinkages were significantly larger for the BVS 1.0 than for the BVS 1.1 (0.98 vs. 0.07 mm² and 13.0 vs. 1.0%, respectively; P = 0.01). Neointimal area was significantly higher in the BVS 1.0 than in the BVS 1.1 (in-scaffold area obstruction of 23.6 vs. 12.3%; P < 0.01). Neointimal thickness was also larger in the BVS 1.0 than in the BVS 1.1 (166.0 vs. 76.4 µm; P < 0.01). Consequently, OCT, intravascular ultrasound, and angiographic luminal losses were higher with the BVS 1.0 than with the BVS 1.1. At 6 months, strut appearance was preserved in only 2.9% of the BVS 1.0 struts, but remained unchanged with the BVS 1.1 indicating different state of strut microstucture and/or their reflectivity. CONCLUSION: The BVS 1.1 has less late shrinkage and less neointimal growth at 6-month follow-up compared with the BVS 1.0. A difference in polymer degradation leading to changes in microstructure and reflectivity is the most plausible explanation for this finding.


Assuntos
Stents Farmacológicos/normas , Imunossupressores/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica/métodos , Idoso , Materiais Biocompatíveis/normas , Prótese Vascular/normas , Angiografia Coronária/métodos , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Desenho de Prótese , Falha de Prótese , Sirolimo/administração & dosagem , Alicerces Teciduais , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA