Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 30(6): 2658-2665, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37491510

RESUMO

The ejection fraction (LVEF) is a commonly used marker of left ventricular function. However, because it is strongly influenced by loading conditions, it can be inaccurate in representing cardiac contractility. We therefore evaluated a gated SPECT based tool to simultaneously assess preload, afterload, and contractility. Using gated SPECT-determined ventricular volumes and arterial tension measurements, we calculated ventricular and arterial elastance (Ev and Ea), as well as end-diastolic volumes, which are surrogates for contractility, afterload, and preload, respectively. We applied this protocol to 1462 consecutive patients and assessed the ventricular function in patients with and without myocardial infarction. The median LVEF was 68% (IQR 62-74%). Patients with infarction exhibited decreased contractility (ventricular elastance of 3 mmHg/ml vs. 6 mmHg/ml), compensated by an increase of preload (end-diastolic volume of 100 ml vs. 78 ml) and a decrease in afterload (arterial elastance of 1.8 mmHg/ml vs. 2.2 ml/mmHg). These interactions yielded a preserved ejection fraction in both groups. Gated SPECT-measured volumes were consistent with values reported in the literature. In addition, the combination of nuclear imaging and arterial tension measurement accounted for not only the ejection fraction but also the loading context, providing a more accurate representation of cardiac contractility.


Assuntos
Contração Miocárdica , Função Ventricular Esquerda , Humanos , Volume Sistólico , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
J Neurol Surg B Skull Base ; 82(5): 540-546, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34513560

RESUMO

Background A nasal access guide (NAG) for endoscopic endonasal approaches (EEAs) to the skull-base has been developed and approved for clinical use but its utility has not been formally investigated. Objective The study aims to assess the effect of a NAG on endoscopic visualization during cadaveric dissection and to perform a workflow analysis with process-based performance measures in the operating room and their effect on clinical outcomes. Methods Skull-base course participants were observed during hands-on cadaveric dissection with and without NAG. Instances of endoscope withdrawal for lens cleaning and inadequate visualization due to lens soiling were tabulated. Participants completed a Likert-scale survey examining the NAG utility and provided an overall grading. Surgical workflow and process-based performance on patients undergoing EEA to the skull-base was analyzed. Passage of powered and dissecting instruments, removal of endoscopes for cleaning, and dislodgment or migration of the device were reviewed. Postoperative assessments included mucosal trauma and synechiae formation. Results Instances of endoscope soiling and manual cleaning were significantly reduced by 40% and 61% with the NAG during cadaveric dissection. The overall grading of the device was 2.75/3. Surgical workflow was observed in 35 patients. Average number of passes of endoscopes, instruments, and powered tools during a 10-minute observation period were 3,17, and 5 during the surgical approach, and 3, 18, and 1 during tumor dissection. Dislodgement of the device occurred in 25.7% and migration of the device in 2.8% of cases. Postoperative synechiae, exposed cartilage or septal perforation was not observed in follow up. Conclusion NAG can significantly reduce inadequate visualization during EEA to the skull-base and has the potential to reduce instances of nasal trauma. Participants assessed its overall utility as being "excellent."

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA