1.
Pain Med ; 24(11): 1219-1223, 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37478345

RESUMO

OBJECTIVE: To evaluate the safety and tolerability of MRI-guided focused ultrasound (MRgFUS) for the treatment of facet joint-mediated pain in human subjects for whom conventional treatment had failed. Secondarily, to evaluate effectiveness of the procedure. METHODS: Consecutive patients who underwent MRgFUS at our institution were retrospectively identified. Chart review was performed to obtain relevant clinical and technical data. All patients had chronic low back pain and positive comparative medial branch blocks. RESULTS: Twenty-six MRgFUS treatments in 20 patients were included. Mean sonication energy was 1436.6 Joules. The procedure was technically successful in all patients. Of the treated patients, 29.6% experienced short-term worsening of low back pain immediately after the procedure, all by 1-4 points on a 0-10 scale. One patient (3.8%) reported temporary worsening of preexisting radicular symptoms after the procedure. Of 21 treatments with clinical follow-up of at least 3 months available, 12 (57.1%) had >3 months' pain relief, 2 (10%) had <3 months' benefit, 6 (30%) reported no benefit, and 1 (5%) patient was lost to follow-up. In patients who reported at least some benefit with prior conventional radiofrequency ablation, 8/10 (80%) benefited from the MRgFUS procedure. CONCLUSION: The present study demonstrates that MRgFUS ablation of the lumbar facet joints is a safe and tolerable procedure in human subjects and could provide another option for patients for whom radiofrequency ablation had failed. More than half of all patients received significant durable pain relief, which jumped to 80% for patients who had experienced at least some benefit from prior radiofrequency ablations.


Assuntos
Dor Lombar , Bloqueio Nervoso , Articulação Zigapofisária , Humanos , Dor Lombar/terapia , Bloqueio Nervoso/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Resultado do Tratamento
2.
J Appl Clin Med Phys ; 19(2): 298-304, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29336119

RESUMO

We evaluated a commercially available software package that uses B-mode images to semi-automatically measure quantitative metrics of ultrasound image quality, such as contrast response, depth of penetration (DOP), and spatial resolution (lateral, axial, and elevational). Since measurement of elevational resolution is not a part of the software package, we achieved it by acquiring phantom images with transducers tilted at 45 degrees relative to the phantom. Each measurement was assessed in terms of measurement stability, sensitivity, repeatability, and semi-automated measurement success rate. All assessments were performed on a GE Logiq E9 ultrasound system with linear (9L or 11L), curved (C1-5), and sector (S1-5) transducers, using a CIRS model 040GSE phantom. In stability tests, the measurements of contrast, DOP, and spatial resolution remained within a ±10% variation threshold in 90%, 100%, and 69% of cases, respectively. In sensitivity tests, contrast, DOP, and spatial resolution measurements followed the expected behavior in 100%, 100%, and 72% of cases, respectively. In repeatability testing, intra- and inter-individual coefficients of variations were equal to or less than 3.2%, 1.3%, and 4.4% for contrast, DOP, and spatial resolution (lateral and axial), respectively. The coefficients of variation corresponding to the elevational resolution test were all within 9.5%. Overall, in our assessment, the evaluated package performed well for objective and quantitative assessment of the above-mentioned image qualities under well-controlled acquisition conditions. We are finding it to be useful for various clinical ultrasound applications including performance comparison between scanners from different vendors.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Software , Transdutores , Ultrassonografia/instrumentação , Desenho de Equipamento , Humanos
3.
Phys Med Biol ; 52(19): 5909-19, 2007 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-17881808

RESUMO

The purpose of this work is to assess a fast technique that measures tissue stiffness and temperature during focused ultrasound thermal therapy (FUS). A one-dimensional (1D) MR elastography (MRE) pulse sequence was evaluated for the purpose of obtaining rapid measurements of thermally induced changes in tissue stiffness and temperature for monitoring FUS treatments. The accuracy of the 1D measurement was studied by comparing tissue displacements measured by 1D MRE with those measured by the well-established 2D MRE pulse sequence. The reproducibility of the 1D MRE measurement was assessed, in gel phantoms and ex vivo porcine tissue, for varied FUS intensity levels (31.5-199.9 W cm(-2)) and over a range of displacements at the focus (0.1-1 microm). Temperature elevations in agarose gel phantoms were measured using 1D MRE and calibrated using fiberoptic-thermometer-based measurements. The 1D MRE displacement measurements are highly correlated with those obtained with the 2D technique (R(2) = 0.88-0.93), indicating that 1D MRE can successfully measure tissue displacement. Ten repeated trials at each FUS power level yielded a minimum detectable displacement change of 0.2 microm in phantoms and 0.4 microm in tissue (at 95% confidence level). The 1D MRE temperature measurements correlated well with temperature changes measured simultaneously with fiberoptic thermometers (R(2) = 0.97). The 1D MRE technique is capable of detecting tissue displacements as low as 0.4 microm, which is an order of magnitude smaller than 5 microm displacements expected during FUS therapy (Le et al 2005 AIP Conf. Proc.: Ther. Ultrasound 829 186-90). Additionally, 1D MRE was shown to provide adequate measurements of temperature elevations in tissue. These findings indicate that 1D MRE may be an effective tool for monitoring FUS treatments.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico , Neoplasias/terapia , Terapia Assistida por Computador/métodos , Terapia por Ultrassom/métodos , Elasticidade , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Projetos Piloto , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Termografia/métodos , Resultado do Tratamento