RESUMO
OBJECTIVES: The purpose of this study was to assess the performance and limitations of low-voltage zones (LVZ) localization by optimized late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) scar imaging in patients with cardiac implantable electronic devices (CIEDs). BACKGROUND: Scar evaluation by LGE-CMR can assist ventricular tachycardia (VT) ablation, but challenges with electroanatomical maps coregistration and presence of imaging artefacts from CIED limit accuracy. METHODS: A total of 10 patients underwent VT ablation and preprocedural LGE-CMR using wideband imaging. Scar was segmented from CMR pixel signal intensity maps using commercial software (ADAS-VT, Galgo Medical) with bespoke tools and compared with detailed electroanatomical maps (CARTO). Coregistration of EP and imaging-derived scar was performed using the aorta as a fiducial marker, and the impact of coregistration was determined by assessing intraobserver/interobserver variability and using computer simulations. Spatial smoothing was applied to assess correlation at different spatial resolutions and to reduce noise. RESULTS: Pixel signal intensity maps localized low-voltage zones (V <1.5 mV) with area under the receiver-operating characteristic curve: 0.82 (interquartile range [IQR]: 0.76-0.83), sensitivity 74% (IQR: 71%-77%), and specificity 78% (IQR: 73%-83%) and correlated with bipolar voltage (r = -0.57 [IQR: -0.68 to -0.42]) across patients. In simulations, small random shifts and rotations worsened LVZ localization in at least some cases. The use of the full aortic geometry ensured high reproducibility of LVZ localization (r >0.86 for area under the receiver-operating characteristic curve). Spatial smoothing improved localization of LVZ. Results for LVZ with V <0.5 mV were similar. CONCLUSIONS: In patients with CIEDs, novel wideband CMR sequences and personalized coregistration strategies can localize LVZ with good accuracy and may assist VT ablation procedures.
Assuntos
Meios de Contraste , Taquicardia Ventricular , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgiaRESUMO
Data presented in this article are supplementary materials to our article entitled "Catheter Ablation for Fascicular Ventricular Tachycardia: A Systematic review" (Creta et al., 2018). The current article provides additional procedural data regarding the catheter ablation for fascicular ventricular tachycardia (FVT) performed in the patients enrolled in our analysis. Furthermore, we provide data regarding the quality assessment of the studies included in our systematic review.
RESUMO
INTRODUCTION: Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. OBJECTIVE: To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. METHODS: EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. RESULTS: Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I2 = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I2 = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I2 = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. CONCLUSION: LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients.
Assuntos
Estimulação Cardíaca Artificial/métodos , Endocárdio/fisiopatologia , Insuficiência Cardíaca/prevenção & controle , Insuficiência Cardíaca/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , HumanosRESUMO
Adrenergic stimulation of brown adipocytes (BA) induces mitochondrial uncoupling, thereby increasing energy expenditure by shifting nutrient oxidation towards thermogenesis. Here we describe that mitochondrial dynamics is a physiological regulator of adrenergically-induced changes in energy expenditure. The sympathetic neurotransmitter Norepinephrine (NE) induced complete and rapid mitochondrial fragmentation in BA, characterized by Drp1 phosphorylation and Opa1 cleavage. Mechanistically, NE-mediated Drp1 phosphorylation was dependent on Protein Kinase-A (PKA) activity, whereas Opa1 cleavage required mitochondrial depolarization mediated by FFAs released as a result of lipolysis. This change in mitochondrial architecture was observed both in primary cultures and brown adipose tissue from cold-exposed mice. Mitochondrial uncoupling induced by NE in brown adipocytes was reduced by inhibition of mitochondrial fission through transient Drp1 DN overexpression. Furthermore, forced mitochondrial fragmentation in BA through Mfn2 knock down increased the capacity of exogenous FFAs to increase energy expenditure. These results suggest that, in addition to its ability to stimulate lipolysis, NE induces energy expenditure in BA by promoting mitochondrial fragmentation. Together these data reveal that adrenergically-induced changes to mitochondrial dynamics are required for BA thermogenic activation and for the control of energy expenditure.