Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(7)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38422544

RESUMO

Objective. An algorithm was developed for automated positioning of lattice points within volumetric modulated arc lattice radiation therapy (VMAT LRT) planning. These points are strategically placed within the gross tumor volume (GTV) to receive high doses, adhering to specific separation rules from adjacent organs at risk (OARs). The study goals included enhancing planning safety, consistency, and efficiency while emulating human performance.Approach. A Monte Carlo-based algorithm was designed to optimize the number and arrangement of lattice points within the GTV while considering placement constraints and objectives. These constraints encompassed minimum spacing between points, distance from OARs, and longitudinal separation along thez-axis. Additionally, the algorithm included an objective to permit, at the user's discretion, solutions with more centrally placed lattice points within the GTV. To validate its effectiveness, the automated approach was compared with manually planned treatments for 24 previous patients. Prior to clinical implementation, a failure mode and effects analysis (FMEA) was conducted to identify potential shortcomings.Main results.The automated program successfully met all placement constraints with an average execution time (over 24 plans) of 0.29 ±0.07 min per lattice point. The average lattice point density (# points per 100 c.c. of GTV) was similar for automated (0.725) compared to manual placement (0.704). The dosimetric differences between the automated and manual plans were minimal, with statistically significant differences in certain metrics like minimum dose (1.9% versus 1.4%), D5% (52.8% versus 49.4%), D95% (7.1% versus 6.2%), and Body-GTV V30% (20.7 c.c. versus 19.7 c.c.).Significance.This study underscores the feasibility of employing a straightforward Monte Carlo-based algorithm to automate the creation of spherical target structures for VMAT LRT planning. The automated method yields similar dose metrics, enhances inter-planner consistency for larger targets, and requires fewer resources and less time compared to manual placement. This approach holds promise for standardizing treatment planning in prospective patient trials and facilitating its adoption across centers seeking to implement VMAT LRT techniques.


Assuntos
Algoritmos , Benchmarking , Humanos , Estudos Prospectivos , Método de Monte Carlo , Órgãos em Risco
2.
Phys Med Biol ; 64(5): 055015, 2019 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-30673655

RESUMO

Radiochromic film (RCF) is a valuable dosimetric tool, primarily due to its sub-millimeter spatial resolution. For accurate proton dosimetry, the dependence of film response on linear energy transfer (LET) must be characterized and calibrated. In this work, we characterized film under-response, or 'quenching', as a function of dose-weighted linear energy transfer (LETd) in several proton fields and established a simple, linear relationship with LETd. We performed measurements as a function of depth in a PMMA phantom irradiated by a spot-scanning proton beam. The fields had energies of 71.3 MeV, 71.3 MeV with filter, and 159.9 MeV. At each depth (measurements taken in depth step sizes of 0.5-1 mm in the Bragg peak), we measured dose with a PTW Markus ion chamber and EBT3 RCF. EBT3 under-response was characterized by the ratio of dose measured with film to that with ion chamber. LETd values for our experimental setup were calculated using in-house clinical Monte Carlo code. Measured film under-response increased with LETd, from approximately 10% under-response for LETd = 5 keV µm-1 to approximately 20% for LETd = 8 keV µm-1. The under-response for all measurements was plotted versus LETd. A linear fit to the data was performed, yielding a function for under-response, [Formula: see text], with respect to LETd: [Formula: see text]. Finally, the linear under-response relationship was applied to a film measurement within a spread-out Bragg peak (SOBP). Without correcting for LETd-dependence in the SOBP measurement, the discrepancy between film and Monte Carlo profiles was greater than 15% at the distal edge. With correction, the corrected film profile was within 2% and 1 mm of the Monte Carlo profile. RCF response depends on LETd, potentially under-responding by >15% in clinically-relevant scenarios. Therefore, it is insufficient to perform only a dose calibration; LET calibration is also necessary for accurate proton film dosimetry. The LETd-dependence of EBT3 can be described by a single, linear function over a range of clinically-relevant proton therapy LETd values.


Assuntos
Dosimetria Fotográfica/métodos , Transferência Linear de Energia , Terapia com Prótons/métodos , Algoritmos , Calibragem , Simulação por Computador , Humanos , Modelos Lineares , Método de Monte Carlo , Imagens de Fantasmas , Polimetil Metacrilato
3.
Int J Radiat Biol ; 90(10): 936-942, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24844370

RESUMO

PURPOSE: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. MATERIALS AND METHODS: A high dose rate (HDR) (192)Ir brachytherapy source from a commercially available afterloader was used with a 1.3 cm thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit was equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film measurements. RESULTS: The tungsten collimator provided a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator, and was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. CONCLUSIONS: Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring steep dose gradients.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/veterinária , Encéfalo/efeitos da radiação , Radioisótopos de Irídio/farmacologia , Irradiação Corporal Total/instrumentação , Irradiação Corporal Total/veterinária , Animais , Braquiterapia/economia , Desenho Assistido por Computador , Análise Custo-Benefício , Desenho de Equipamento , Análise de Falha de Equipamento , Radioisótopos de Irídio/economia , Camundongos , Miniaturização , Doses de Radiação , Radiometria/economia , Radiometria/instrumentação , Radiometria/veterinária , Irradiação Corporal Total/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA