1.
Crit Care ; 23(1): 348, 2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31694688

RESUMO

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO2R) uses an extracorporeal circuit to directly remove carbon dioxide from the blood either in lieu of mechanical ventilation or in combination with it. While the potential benefits of the technology are leading to increasing use, there are very real risks associated with it. Several studies demonstrated major bleeding and clotting complications, often associated with hemolysis and poorer outcomes in patients receiving ECCO2R. A better understanding of the risks originating specifically from the rotary blood pump component of the circuit is urgently needed. METHODS: High-resolution computational fluid dynamics was used to calculate the hemodynamics and hemocompatibility of three current rotary blood pumps for various pump flow rates. RESULTS: The hydraulic efficiency dramatically decreases to 5-10% if operating at blood flow rates below 1 L/min, the pump internal flow recirculation rate increases 6-12-fold in these flow ranges, and adverse effects are increased due to multiple exposures to high shear stress. The deleterious consequences include a steep increase in hemolysis and destruction of platelets. CONCLUSIONS: The role of blood pumps in contributing to adverse effects at the lower blood flow rates used during ECCO2R is shown here to be significant. Current rotary blood pumps should be used with caution if operated at blood flow rates below 2 L/min, because of significant and high recirculation, shear stress, and hemolysis. There is a clear and urgent need to design dedicated blood pumps which are optimized for blood flow rates in the range of 0.5-1.5 L/min.


Assuntos
Desenho de Equipamento/normas , Oxigenação por Membrana Extracorpórea/instrumentação , Teste de Materiais/métodos , Desenho de Equipamento/estatística & dados numéricos , Circulação Extracorpórea/métodos , Circulação Extracorpórea/normas , Oxigenação por Membrana Extracorpórea/tendências , Hemodinâmica/fisiologia , Humanos , Estresse Mecânico
2.
J Biomech Eng ; 141(2)2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30458464

RESUMO

The reduction of excessive, nonphysiologic shear stresses leading to blood trauma can be the key to overcome many of the associated complications in blood recirculating devices. In that regard, computational fluid dynamics (CFD) are gaining in importance for the hydraulic and hemocompatibility assessment. Still, direct hemolysis assessments with CFD remain inaccurate and limited to qualitative comparisons rather than quantitative predictions. An underestimated quantity for improved blood damage prediction accuracy is the influence of near-wall mesh resolution on shear stress quantification in regions of complex flows. This study investigated the necessary mesh refinement to quantify shear stress for two selected, meshing sensitive hotspots within a rotary centrifugal blood pump (the blade leading edge and tip clearance gap). The shear stress in these regions is elevated due to presence of stagnation points and the flow around a sharp edge. The nondimensional mesh characteristic number y+, which is known in the context of turbulence modeling, underestimated the maximum wall shear stress by 60% on average with the recommended value of 1, but was found to be exact below 0.1. To evaluate the meshing related error on the numerical hemolysis prediction, three-dimensional simulations of a generic centrifugal pump were performed with mesh sizes from 3 × 106 to 30 × 106 elements. The respective hemolysis was calculated using an Eulerian scalar transport model. Mesh insensitivity was found below a maximum y+ of 0.2 necessitating 18 × 106 mesh elements. A meshing related error of up to 25% was found for the coarser meshes. Further investigations need to address: (1) the transferability to other geometries and (2) potential adaptions on blood damage estimation models to allow better quantitative predictions.