Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Open Heart ; 8(1)2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33462106

RESUMO

INTRODUCTION: In patients with chronic coronary syndrome, percutaneous coronary intervention targets haemodynamically significant stenoses, that is, those thought to cause ischaemia. Intracoronary ECG (icECG) detects ischaemia directly where it occurs. Thus, the goal of this study was to test the accuracy of icECG during pharmacological inotropic stress to determine functional coronary lesion severity in comparison to the structural parameter of quantitative angiographic per cent diameter stenosis (%S), as well as to the haemodynamic indices of fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). METHOD: The primary study endpoint of this prospective trial was the maximal change in icECG ST-segment shift during pharmacological inotropic stress induced by dobutamine plus atropine obtained within 1 min after reaching maximal heart rate(=220 - age). IcECG was acquired by attaching an alligator clamp to the angioplasty guidewire positioned downstream of the stenosis. For the pressure-derived stenosis severity ratios, coronary perfusion pressure and simultaneous aortic pressure were continuously recorded. RESULTS: There was a direct linear relation between icECG ST-segment shift and %S: icECG=-0.8+0.03*%S (r2=0.164; p<0.0001). There were inverse linear correlations between FFR and %S: FFR=1.1-6.1*10-3*%S (r2=0.494; p<0.0001), and between iFR and %S: iFR=1.27-8.6*10-3*%S (r2=0.461; p<0.0001). Using a %S-threshold of ≥50% as the reference for structural stenosis relevance, receiver operating characteristics-analysis of absolute icECG ST-segment shift during hyperemia showed an area under the curve (AUC) of 0.678±0.054 (p=0.002; sensitivity=85%, specificity=50% at 0.34 mV). AUC for FFR was 0.854±0.037 (p<0.0001; sensitivity=64%, specificity=96% at 0.78), and for iFR it was 0.816±0.043 (p<0.0001;sensitivity=62%, specificity=96% at 0.83). CONCLUSIONS: Hyperaemic icECG ST-segment shift detects structurally relevant coronary stenotic lesions with high sensitivity, while they are identified highly specific by FFR and iFR.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Isquemia Miocárdica/diagnóstico , Função Ventricular/fisiologia , Idoso , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Isquemia Miocárdica/fisiopatologia , Estudos Prospectivos
2.
Circ Cardiovasc Interv ; 12(7): e007744, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31272228

RESUMO

BACKGROUND: The present study aimed to quantitatively measure the pressure-derived function of the palmar arch and forearm arterial collateral circulation during transradial access. METHODS AND RESULTS: Palmar arch and forearm collateral function was determined using radial artery pressure signals in the nonobstructed vessel and during brief manual occlusions of the more proximal radial artery and of the radial plus ulnar arteries. Collateral flow index (CFI), the ratio of mean occlusive divided by mean nonocclusive arterial blood pressure, both subtracted by central venous pressure, was determined for CFI during radial artery occlusion (CFIrad) and CFI during radial plus ulnar artery occlusion. Before invasive CFI measurements, arterial palmar arch and forearm function was tested noninvasively by the modified Allen test (MAT). Two hundred fifty patients undergoing transradial access coronary angiography were included in the study. CFIrad was equal to 0.802±0.150 (95% CI, 0.783-0.820). CFI during radial plus ulnar artery occlusion was equal to 0.424±0.188 (95% CI, 0.400-0.447). There was an inverse linear relation between CFIrad and MAT in seconds (s): MAT=64-63×CFIrad ( r2=0.229; P<0.0001). Two hundred eleven patients had a normal and 39 patients an abnormal (>15 seconds) MAT. The group with normal MAT had a CFIrad of 0.830±0.111, and patients with abnormal MAT had a CFIrad of 0.648±0.224 ( P<0.0001). CONCLUSIONS: Direct invasive hemodynamic assessment of the palmar arch and forearm arterial function reveals collateral supply to the briefly occluded in comparison to the patent radial artery of 0.802. During external occlusion of both radial and ulnar artery, CFI amounts to an unexpectedly high value of 0.424.


Assuntos
Cateterismo Periférico , Circulação Colateral , Antebraço/irrigação sanguínea , Mãos/irrigação sanguínea , Hemodinâmica , Artéria Radial/fisiopatologia , Artéria Ulnar/fisiopatologia , Idoso , Pressão Arterial , Velocidade do Fluxo Sanguíneo , Cateterismo Periférico/efeitos adversos , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Punções , Fluxo Sanguíneo Regional , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA