Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ophthalmology ; 130(1): 111-119, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36652194

RESUMO

PURPOSE: To investigate the extent of iris trabecular contact (ITC) measured by anterior segment OCT (AS-OCT) and its association with primary angle-closure (PAC) and PAC glaucoma (PACG) in eyes with gonioscopic angle-closure and to determine the diagnostic performance of ITC for detection of gonioscopic angle-closure. DESIGN: Multicenter, prospective study. PARTICIPANTS: A total of 119 healthy participants with gonioscopic open-angle and 170 patients with gonioscopic angle-closure (94 with PAC suspect and 76 with PAC/PACG) were included. METHODS: One eye of each subject was randomly selected for AS-OCT imaging. Angle-opening distance (AOD500) and trabecular iris space area (TISA500) were measured every 10° for 360°. Two criteria of ITC500 were examined: (1) AOD500 = 0 mm and (2) TISA500 = 0 mm2. The association between the extent of ITC500 and PAC/PACG in eyes with gonioscopic angle-closure was analyzed with logistic regression analysis. MAIN OUTCOME MEASURES: Sensitivity and specificity of ITC500 for detection of gonioscopic angle-closure; odds ratio (OR) of PAC/PACG. RESULTS: The sensitivity of ITC500 ≥ 10° for detection of gonioscopic angle-closure ranged from 82.4% (AOD500 = 0 mm) to 84.7% (TISA500 = 0 mm2), and the specificity was 85.7% (for both AOD500 = 0 mm and TISA500 = 0 mm2). The extent of ITC500 determined by AS-OCT, not cumulative gonioscopy score (i.e., the sum of the modified Shaffer grades over 4 quadrants), was associated with the odds of PAC/PACG in eyes with gonioscopic angle-closure; the odds of PAC/PACG increased by 5% for every 10° increase in ITC500 (OR, 1.051, 95% confidence interval [CI], 1.022-1.080 for AOD500 = 0 mm; OR, 1.049, 95% CI, 1.022-1.078 for TISA500 = 0 mm2). Axial length and anterior chamber depth were not associated with PAC/PACG in eyes with gonioscopic angle-closure (P ≥ 0.574). CONCLUSIONS: A greater extent of ITC measured by AS-OCT, not angle-closure determined by gonioscopy, was associated with a greater odds of PAC/PACG in eyes with gonioscopic angle-closure.


Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Humanos , Gonioscopia , Estudos Prospectivos , Pressão Intraocular , Tomografia de Coerência Óptica/métodos , Iris , Glaucoma de Ângulo Fechado/diagnóstico
2.
Nat Biomed Eng ; 6(5): 593-604, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34992272

RESUMO

The clinical diagnostic evaluation of optic neuropathies relies on the analysis of the thickness of the retinal nerve fibre layer (RNFL) by optical coherence tomography (OCT). However, false positives and false negatives in the detection of RNFL abnormalities are common. Here we show that an algorithm integrating measurements of RNFL thickness and reflectance from standard wide-field OCT scans can be used to uncover the trajectories and optical texture of individual axonal fibre bundles in the retina and to discern distinctive patterns of loss of axonal fibre bundles in glaucoma, compressive optic neuropathy, optic neuritis and non-arteritic anterior ischaemic optic neuropathy. Such optical texture analysis can detect focal RNFL defects in early optic neuropathy, as well as residual axonal fibre bundles in end-stage optic neuropathy that were indiscernible by conventional OCT analysis and by red-free RNFL photography. In a diagnostic-performance study, optical texture analysis of the RNFL outperformed conventional OCT in the detection of glaucoma, as defined by visual-field testing or red-free photography. Our findings show that optical texture analysis of the RNFL for the detection of optic neuropathies is highly sensitive and specific.


Assuntos
Glaucoma , Doenças do Nervo Óptico , Glaucoma/diagnóstico por imagem , Humanos , Fibras Nervosas/patologia , Doenças do Nervo Óptico/diagnóstico por imagem , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA