Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 18(7): 780-786, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27461206

RESUMO

AIMS: Understanding normal asymmetry in the aortic root could aid in the development of new surgical repair techniques or devices with improved haemodynamic performance. The purpose of this study was to assess geometric asymmetry and age-related changes in the normal aortic root using 3D computed tomography. METHODS AND RESULTS: The institutional review board approved this retrospective study of 130 normal subjects (mean age, 51.4 years; 58 men). Specialized 3D software measured individual cusp sinus volumes (CSVs), cusp surface areas (CSAs), and intercommissural distances (ICDs). Age-related aortic root changes were evaluated with simple correlation, ANOVA test among age groups, and multivariable linear regression analyses. The CSV and CSA of left coronary cusp (LCC) were significantly smaller than those of right coronary cusp (RCC) and non-coronary cusp (NCC) (both, P < 0.001) in all age groups. The mean ratios of RCC or NCC-to-LCC were 1.38 and 1.36 for CSV, 1.19 and 1.20 for CSA, and 1.21 and 1.06 for ICD, respectively. The CSV and ICD increased in older age with weak-to-moderate correlation coefficients in both men and women. By multivariable linear regression, CSVs and ICDs of all cusps showed a positive correlation with age (P < 0.05), and the female gender was associated with a smaller size of the CSV and CSA. CONCLUSIONS: The LCC was significantly smaller than the other two cusps, and the aortic root size increased with age.


Assuntos
Aorta Torácica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional , Adulto , Fatores Etários , Idoso , Envelhecimento/fisiologia , Análise de Variância , Estudos de Coortes , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Medição de Risco , Sensibilidade e Especificidade , Fatores Sexuais
3.
Circ Cardiovasc Imaging ; 6(5): 784-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23873402

RESUMO

BACKGROUND: Mitral valve (MV) enlargement is a compensatory mechanism capable of preventing functional mitral regurgitation (FMR) in dilated ventricles. Total leaflet area and its relation with closure area measured by 3-dimensional (3D) echocardiography have been related to FMR. Whether these parameters can be assessed with other imaging modalities is not known. Our objectives are to compare cardiac computed tomography (CT)-based measurements of MV leaflets with 3D echocardiography and determine the relationship of these metrics to the presence of FMR. METHODS AND RESULTS: We used 2 cohorts of patients who had cardiac CT to measure MV total leaflet, closure, and annulus areas. In cohort 1 (26 patients), we validated these CT metrics to 3D echocardiography. In cohort 2 (66 patients), we assessed the relation of MV size with the presence of FMR in 3 populations: heart failure with FMR, heart failure without FMR, and normal controls. Cardiac CT and 3D echocardiography produced similar results for total leaflet (R(2)=0.97), closure (R(2)=0.89), and annulus areas (R(2)=0.84). MV size was the largest in heart failure without FMR compared with controls and patients with FMR (9.1 ± 1.7 versus 7.5 ± 1.0 versus 8.1 ± 0.9 cm(2)/m(2); P<0.01). Patients with FMR had reduced ratios of total leaflet to closure areas and total leaflet to annulus areas when compared with patients without FMR (P<0.01). CONCLUSIONS: MV size measured by CT is comparable with 3D echocardiography. MV enlargement in cardiomyopathy suggests leaflet adaptation. Patients with FMR have inadequate adaptation as reflected by decreased ratios of leaflet area and areas determined by ventricle size (annulus and closure areas). These measurements provide additional insight into the mechanism of FMR.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Adaptação Fisiológica , Adulto , Idoso , Análise de Variância , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
Eur J Echocardiogr ; 10(5): 619-24, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19258335

RESUMO

AIMS: Two-dimensional echocardiographic (2DE) assessment of right ventricular (RV) function is difficult, often resulting in inconsistent RV evaluation. Real-time three-dimensional echocardiography (RT3DE) allows the RV to be viewed in multiple planes, which can potentially improve RV assessment and limit interobserver variability when compared with 2DE. METHODS AND RESULTS: Twenty-five patients underwent 2DE and RT3DE. Views of 2DE (RV inflow, RV short axis, and apical four-chamber) were compared with RT3DE views by four readers. RT3DE data sets were sliced from anterior-posterior (apical view) and from base to apex (short axis) to obtain six standardized planes. Readers recorded the RV ejection fraction (RVEF) from 2DE and RT3DE images. RVEF recorded by RT3DE (RVEF(3D)) and 2D (RVEF(2D)) were compared with RVEF by disc summation (RVEF(DS)), which was used as a reference. Interobserver variability among readers of RVEF(3D) and RVEF(2D) was then compared. Overall, mean RVEF(DS), RVEF(3D), and RVEF(2D) were 37 +/- 11%, 38 +/- 10%, 41 +/- 10%, respectively. The mean difference of RVEF(3D)-RVEF(DS) was significantly less than RVEF(2D)-RVEF(DS) (3.7 +/- 4% vs. 7.1 +/- 5%, P = 0.0066, F-test). RVEF(3D) correlated better with RVEF(DS) (r = 0.875 vs. r = 0.69, P = 0.028, t-test). RVEF(3D) was associated with a 39% decrease in interobserver variability when compared with RVEF(2D) [standard deviation of mean difference: 3.7 vs. 5.1, (RT3DE vs. 2DE), P = 0.018, t-test]. CONCLUSIONS: RT3DE provides improved accuracy of RV function assessment and decreases interobserver variability when compared with 2D views.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Direita , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos
6.
Am J Cardiol ; 96(8): 1151-6, 2005 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-16214455

RESUMO

Two-dimensional (2-D) planimetry is limited by the technical demands, time, and observer variability required to locate the minimal orifice area, limiting the confident clinical reporting of mitral valve area (MVA). In 27 consecutive patients, MVA was determined independently by 2 observers using the conventional 2-D method and a new 3-D-guided method. Using a matrix-array probe, the valve was visualized in a long-axis view and a cursor steered to intersect the leaflet tips and provide a perpendicular short-axis plane viewed side-by-side. Two-dimensional and 3-D-guided methods allowed planimetry in 24 patients. Consistent with better orifice localization, 3-D guidance eliminated the overestimation of internal orifice diameters in the planimetered short-axis view relative to the limiting diameter defined by the long-axis view (for 3-D guidance, 0.73 +/- 0.20 vs 0.73 +/- 0.21 cm, p = 0.98, vs 0.90 +/- 0.27 cm in the 2-D short-axis view, p <0.01). Accordingly, mean values for the smallest orifice area by 3-D guidance were less than by 2-D imaging (1.4 +/- 0.5 vs 1.5 +/- 0.5 cm(2), p <0.01), changing the clinical severity classification in 11 of 24 patients (46%). The 2-D method also overestimated MVA relative to 3-D guidance compared with Doppler pressure halftime and (n = 6) Gorlin areas. Phantom studies verified no differences in resolution for the 2 acquisition modes. Three-dimensional guidance reduced intraobserver variability from 9.8% to 3.8% (SEE 0.14 to 0.06 cm(2), p <0.01) and interobserver variability from 10.6% to 6.1% (SEE 0.15 to 0.09 cm(2), p <0.02). In conclusion, matrix-array technology provides a feasible and highly reproducible direct 3-D-guided method for measuring the limiting mitral orifice area.


Assuntos
Ecocardiografia Tridimensional/métodos , Estenose da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/classificação , Estenose da Valva Mitral/patologia , Índice de Gravidade de Doença
7.
Circulation ; 111(20): 2611-6, 2005 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-15897347

RESUMO

BACKGROUND: Tissue Doppler imaging (TDI) is a novel echocardiographic method to quantify regional myocardial function. The objective of this study was to assess whether myocardial velocities and strain rate (SR) could be obtained by TDI in mice and whether these indices accurately quantified alterations in left ventricular (LV) systolic function. METHODS AND RESULTS: TDI was performed in 10 healthy mice to measure endocardial (v(endo)) and epicardial systolic velocities and SR. In further experiments, TDI indices were compared with dP/dt(max) and with sonomicrometer-derived regional velocities, at rest and after administration of dobutamine or esmolol. TDI indices were also studied serially in 8 mice before and 4 and 7 hours after endotoxin challenge. Myocardial velocities and SR were obtained in all mice with low measurement variability. TDI indices increased with administration of dobutamine (v(endo) from 2.2+/-0.3 to 3.8+/-0.2 cm/s [P<0.01]; SR from 12+/-2 to 20+/-2 s(-1) [P<0.05]) and decreased with administration of esmolol (v(endo) 1.4+/-0.2 cm/s [P<0.05]; SR 6+/-1 s(-1) [P<0.01]). Both indices correlated strongly with dP/dt(max) (r2=0.79 for SR and r2= 0.69 for v(endo); both P<0.0001). SR and shortening fraction were predictors of dP/dt(max) even after adjustment for the confounding effect of the other variables. V(endo) correlated closely with sonomicrometer-measured velocity (r2=0.71, P<0.0005). After endotoxin challenge, decreases in both v(endo) and SR were detected before decreases in shortening fraction became manifest. CONCLUSIONS: Myocardial velocities and SR can be measured noninvasively in mice with the use of TDI. Both indices are sensitive markers for quantifying LV global and regional function in mice.


Assuntos
Ecocardiografia Doppler , Disfunção Ventricular Esquerda/diagnóstico , Animais , Cardiotônicos/farmacologia , Dobutamina/farmacologia , Ecocardiografia Doppler/métodos , Ecocardiografia Doppler/normas , Endotoxinas/farmacologia , Testes de Função Cardíaca , Frequência Cardíaca , Cinética , Camundongos , Movimento , Propanolaminas/farmacologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA