1.
Acta Radiol ; 54(8): 954-60, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23612431

RESUMO

BACKGROUND: The effects of a tin filter on virtual non-enhanced (VNE) images created by dual-energy CT have not been well evaluated. PURPOSE: To compare the accuracy of VNE images between those with and without a tin filter. MATERIAL AND METHODS: Two different types of columnar phantoms made of agarose gel were evaluated. Phantom A contained various concentrations of iodine (4.5-1590 HU at 120 kVp). Phantom B consisted of a central component (0, 10, 25, and 40 mgI/cm(3)) and a surrounding component (0, 50, 100, and 200 mgI/cm(3)) with variable iodine concentration. They were scanned by dual-source CT in conventional single-energy mode and dual-energy mode with and without a tin filter. CT values on each gel at the corresponding points were measured and the accuracy of iodine removal was evaluated. RESULTS: On VNE images, the CT number of the gel of Phantom A fell within the range between -15 and +15 HU under 626 and 881 HU at single-energy 120 kVp with and without a tin filter, respectively. With attenuation over these thresholds, iodine concentration of gels was underestimated with the tin filter but overestimated without it. For Phantom B, the mean CT numbers on VNE images in the central gel component surrounded by the gel with iodine concentrations of 0, 50, 100, and 200 mgI/cm(3) were in the range of -19-+6 HU and 21-100 HU with and without the tin filter, respectively. CONCLUSION: Both with and without a tin filter, iodine removal was accurate under a threshold of iodine concentration. Although a surrounding structure with higher attenuation decreased the accuracy, a tin filter improved the margin of error.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estanho , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sefarose
2.
J Magn Reson Imaging ; 26(2): 274-8, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17610284

RESUMO

PURPOSE: To assess the state and dynamics of the intracranial system in idiopathic normal-pressure hydrocephalus (I-NPH), we determined intracranial compliance using magnetic resonance imaging (MRI). MATERIALS AND METHODS: The intracranial compliance index (ICCI), which was defined as the ratio of the peak-to-peak intracranial volume change (ICVC(p-p)) to the peak-to-peak cerebrospinal fluid (CSF) pressure gradient (PG(p-p)) during the cardiac cycle, was obtained from the net transcranial blood and CSF flow measured with phase-contrast (PC) cine MRI. ICCI was determined in patients with I-NPH (N = 7), brain atrophy, or asymptomatic ventricular dilation (VD) (N = 6), and in healthy volunteers (control group; N = 11). The changes in ICCI indices were also analyzed after a CSF tap test (N = 2). RESULTS: The ICCI in the I-NPH group was significantly lower than in the control and VD groups, whereas no difference was found between the control and VD groups. The ICVC(p-p) was also lower than in the control and VD groups. However, no significant difference was found in the PG(p-p) between groups. The ICCI increased after the tap test. CONCLUSION: Intracranial compliance analysis with MRI makes it possible to noninvasively obtain more detailed information of intracranial biomechanics in the I-NPH and to assist in the diagnosis of I-NPH.


Assuntos
Encéfalo/patologia , Hidrocefalia de Pressão Normal/diagnóstico , Hidrocefalia de Pressão Normal/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes
3.
Ann Nucl Med ; 18(6): 483-8, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15515747

RESUMO

OBJECTIVE: To evaluate the accuracy of diagnosing N3 disease using positron emission tomography (PET) with 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG) in patients with pulmonary disease. SUBJECTS AND METHODS: Twenty patients diagnosed as FDG-PET N3 were enrolled. On FDG-PET, lymph nodes were considered to be positive when increased uptake as compared with that of the surrounding mediastinum was visually observed, or the mean standardized uptake ratio (SUR) was more than 2, 2.5, or 3. On CT, lymph nodes exceeding 1 cm in the shortest diameter were regarded as positive. RESULTS: The PET result was true positive (TP) in 2 patients and false positive (FP) in 18 with an overall accuracy (OA) of 10% using visual criteria. Using an SUR of more than 2.5, the result was TP in 2, FP in 3, and true negative (TN) in 15, the false negative (FN) in 0, with an OA of 85%. CT diagnosis was TP in 2, FP in 9, and TN in 9 with an OA of 55%. The accuracy using the SUR criteria of more than 2.5 was superior to that of CT. CONCLUSION: Of 20 patients with the diagnosis of PET N3, we found frequent over-diagnosis in nodal staging using the visual criteria.


Assuntos
Carcinoma/diagnóstico por imagem , Erros de Diagnóstico , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Carcinoma/diagnóstico , Carcinoma/patologia , Reações Falso-Positivas , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade