RESUMO
The 143 low- and middle-income countries (LMICs) of the world constitute 80% of the world's population or roughly 5.86 billion people with much variation in geography, culture, literacy, financial resources, access to health care, insurance penetration, and healthcare regulation. Unfortunately, their burden of cardiovascular disease in general and acute ST-segment-elevation myocardial infarction (STEMI) in particular is increasing at an unprecedented rate. Compounding the problem, outcomes remain suboptimal because of a lack of awareness and a severe paucity of resources. Guideline-based treatment has dramatically improved the outcomes of STEMI in high-income countries. However, no such focused recommendations exist for LMICs, and the unique challenges in LMICs make directly implementing Western guidelines unfeasible. Thus, structured solutions tailored to their individual, local needs, and resources are a vital need. With this in mind, a multicountry collaboration of investigators interested in LMIC STEMI care have tried to create a consensus document that extracts transferable elements from Western guidelines and couples them with local realities gathered from expert experience. It outlines general operating principles for LMICs focused best practices and is intended to create the broad outlines of implementable, resource-appropriate paradigms for management of STEMI in LMICs. Although this document is focused primarily on governments and organizations involved with improvement in STEMI care in LMICs, it also provides some specific targeted information for the frontline clinicians to allow standardized care pathways and improved outcomes.
Assuntos
Consenso , Países em Desenvolvimento/economia , Recursos em Saúde/economia , Pobreza/economia , Infarto do Miocárdio com Supradesnível do Segmento ST/economia , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Serviços Médicos de Emergência/economia , Serviços Médicos de Emergência/normas , Pessoal de Saúde/economia , Pessoal de Saúde/normas , Recursos em Saúde/normas , Humanos , Intervenção Coronária Percutânea/economia , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Terapia Trombolítica/economia , Terapia Trombolítica/normasRESUMO
AIMS: TTK Chitra heart valve prosthesis (CHVP), a tilting disc mechanical heart valve of low cost and proven efficacy, has been in use for the last 15 years. Although various studies substantiating its long-term safety and efficacy are available, no study had assessed its echocardiographic characteristics. The purpose of this study was to determine the normal Doppler parameters of CHVP in the mitral position and to assess whether derivation of mitral valve area (MVA) using the continuity equation (CE) and more commonly used pressure half-time (PHT) method is comparable in the functional assessment of this tilting disc mitral prosthesis. METHODS AND RESULTS: Doppler echocardiography was performed in 40 consecutive patients with CHVP in the mitral position. All patients were clinically stable, without evidence of prosthetic valve dysfunction such as significant obstruction or regurgitation, endocarditis, left ventricular dysfunction (ejection fraction <40%), or significant aortic regurgitation. Valve sizes studied included 25, 27, and 29 mm. Mitral valve area was derived both by the PHT method and by the CE, using the stroke volume measured in the ventricular outflow tract divided by the time-velocity integral of CHVP jet. The peak Doppler gradient ranged from 5 to 21 (mean 11.0) mmHg, and the mean gradient ranged from 1.7 to 9.2 (mean 4.1) mmHg. Mean gradient negatively correlated with an increase in the actual orifice area (AOA) derived from the valve orifice diameter given by the manufacturer (r = -0.45, P = 0.004). Mitral valve area calculated by both PHT and CE increased significantly with an increase in the AOA (r = 0.42, P = 0.007 and r = 0.32, P = 0.046, respectively). Mitral valve area by the CE averaged 1.55 +/- 0.36 cm(2) (range 0.85 cm(2) for a 25 mm valve to 2.41 cm(2) for a 29 mm valve) and was smaller than by PHT (mean 2.04 +/- 0.41 cm(2), range 1.40-3.14 cm(2); P = 0.0001; t-test), irrespective of whether PHT is less than or >110 ms. CONCLUSION: The Doppler parameters obtained with CHVP in the mitral position are comparable with those obtained with the different prosthetic valves in common use. In the selected group of patients with CHVP, assessment of MVA by the PHT method is comparable with that by the CE. Areas by both methods were smaller than the AOA provided by the manufacturer, as seen in other similar design valves.