1.
Acad Radiol ; 30(6): 1129-1140, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35871059

RESUMO

RATIONALE AND OBJECTIVES: High-resolution T2-weighted magnetic resonance imaging (MRI) of the pelvis is the main technique used for diagnosing benign and malignant uterine diseases. However, the procedure may be time-consuming and requires training and experience. Therefore, this study was performed to compare the image quality of standard clinical BLADE (stBLADE) with a prototypical accelerated simultaneous multi-slice (SMS) BLADE procedure with either improved temporal resolution (tr) at the same slice thickness (SL) or improved spatial resolution (sr) with the same examination time and a prototypical isotropic 3D SPACE procedure with inner-volume excitation and iterative denoising. MATERIALS AND METHODS: Patients who underwent clinically indicated MRI of the uterus were included in this prospective study and underwent stBLADE (acquisition time, 2 min 59 s; SL, 4 mm) and SMS BLADE (tr) with the same SL (4 mm) but reduced examination time (1 min 20 s) as well as SMS BLADE (sr) with thinner slices (3 mm) and comparable examination time (3 min 16 s). In addition, 3D SPACE was acquired in a sagittal orientation (5 min 36 s). The short axis of the cervix and the long axis of the corpus uteri were reconstructed in 1-mm and 3-mm SLs, retrospectively. Subjective overall image impression, delineation of anatomy/organs, lesion demarcation, and motion artifacts were assessed using a 5-point Likert scale and compared among the different techniques. The preferred sequence was then selected by three independent assessors. RESULTS: The analysis was based on 38 women (mean age, 44 ± 15 years). The overall image impression was similar for stBLADE, SMS BLADE (sr), and SMS BLADE (tr) but was significantly lower for 3D SPACE than stBLADE (p = 0.01). SMS BLADE (sr) was considered the preferred sequence because of slightly better performance in terms of overall image impression, organ delineation, and lesion demarcation, but without statistical significance. Both SMS BLADE (tr) and (sr) produced significantly fewer motion artifacts than stBLADE (p < 0.01 and p = 0.01), with no significant difference between SMS BLADE (tr) and (sr), while 3D SPACE had a significantly lower rating than stBLADE (p < 0.01). Image quality was rated as the least diagnostic criterion in all sequences and all cases. CONCLUSION: SMS BLADE (sr) was the preferred sequence for MRI of the female pelvis, with higher sr than stBLADE. SMS BLADE (tr) may also be used to reduce the acquisition time without compromising image quality. Despite its lower image quality, 3D SPACE can also reduce the examination time and improve the workflow because of the possibility of retrospective multiplanar reconstructions.


Assuntos
Imageamento por Ressonância Magnética , Pelve , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Estudos Retrospectivos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Pelve/diagnóstico por imagem , Útero/diagnóstico por imagem , Artefatos
2.
In Vivo ; 35(4): 2217-2226, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34182500

RESUMO

BACKGROUND/AIM: To determine whether a prototypical compressed-sensing volume-interpolated breath-hold (csVIBE) provides diagnostic value in detecting rectosigmoid infiltration in deep infiltrating endometriosis (DIE). PATIENTS AND METHODS: csVIBE was employed in 151 women undergoing pelvic magnetic resonance imaging, of whom 43 had undergone surgery for suspected endometriosis. The accuracy of T2-weighted BLADE and BLADE/csVIBE, additional diagnostic value of csVIBE, and diagnostic confidence were rated by two readers. Additionally, the presence of the "mushroom cap sign" was assessed on BLADE and csVIBE. RESULTS: The diagnostic accuracy, sensitivity, and specificity of BLADE and BLADE/csVIBE were not significantly different between Readers A and B. For both readers, the confidence in the diagnosis increased with csVIBE, but this increase in the odds ratio was not significant for both readers. Both readers preferred csVIBE over BLADE with regard to detection of the "mushroom cap sign." CONCLUSION: csVIBE may provide a diagnostic benefit for surgical strategy selection through better delineation of the "mushroom cap sign."


Assuntos
Endometriose , Endometriose/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Pelve , Reto , Sensibilidade e Especificidade
3.
Acta Radiol ; 62(5): 695-704, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32600068

RESUMO

BACKGROUND: The combination of motion-insensitive, high-temporal, and spatial resolution imaging with evaluation of quantitative perfusion has the potential to increase the diagnostic capabilities of magnetic resonance imaging (MRI) in the female pelvis. PURPOSE: To compare a free-breathing compressed-sensing VIBE (fbVIBE) with flexible temporal resolution (range = 4.6-13.8 s) with breath-hold VIBE (bhVIBE) and to evaluate the potential value of quantifying uterine perfusion. MATERIAL AND METHODS: A total of 70 datasets from 60 patients (bhVIBE: n = 30; fbVIBE: n = 40) were evaluated by two radiologists. Only temporally resolved reconstruction (fbVIBE) was performed on 30 of the fbVIBE datasets. For a subset (n = 10) of the fbVIBE acquisitions, a time- and motion-resolved reconstruction (mrVIBE) was evaluated. Image quality (IQ), artifacts, diagnostic confidence (DC), and delineation of uterine structures (DoS) were graded on Likert scales (IQ/DC/DoS: 1 (non-diagnostic) to 5 (perfect); artifacts: 1 (no artifacts) to 5 (severe artifacts)). A Tofts model was applied for perfusion analysis. Ktrans was obtained in the myometrium (Mm), junctional zone (Jz), and cervix (Cx). RESULTS: The median IQ/DoS/DC scores of fbVIBE (4/5/5 κ >0.7-0.9) and bhVIBE (4/4/4; κ = 0.5-0.7; P > 0.05) were high, but Artifacts were graded low (fbVIBE/bhVIBE: 2/2; κ = 0.6/0.5; P > 0.05). Artifacts were only slightly improved by the additional motion-resolved reconstruction (fbVIBE/mrVIBE: 2/1.5; P = 0.08); fbVIBE was preferred in most cases (7/10). Significant differences of Ktrans values were found between Cx, Jz, and Mm (0.12/0.21/0.19; P < 0.05). CONCLUSION: The fbVIBE sequence allows functional and morphological assessment of the uterus at comparable IQ to bhVIBE.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças Uterinas/diagnóstico por imagem , Doenças Uterinas/fisiopatologia , Útero/diagnóstico por imagem , Útero/fisiologia , Adulto , Artefatos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Respiração
4.
Anticancer Res ; 38(2): 969-978, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29374729

RESUMO

AIM: The purpose of this IRB-approved, retrospective study was to compare image quality between 2D and high-resolution 3D, T2-weighted (T2WI) magnetic resonance imaging (MRI) sequences and to investigate the additional value of ultra-high b-value diffusion-weighted imaging (DWI; b=2,000 mm/s2) for both rectal cancer staging and evaluating treatment response. MATERIALS AND METHODS: From 12 February to 24 August 2016, 26 consecutive patients (22 males, four females; mean age: 61.9±14.0 years) with histologically-proven rectal cancer. In total 31 examinations [12 prior to and 19 after chemoradiation (CRT)] were included. The patients underwent pelvic MRI on a 3.0-T scanner (Magnetom Skyra, Erlangen, Germany). Three radiologists (3, 4, and 5 years of experience in MRI, respectively) independently assessed all images and rated the image quality of DWI (b=800 mm/s2), apparent diffusion coefficient map, DWI (b=2,000 mm/s2), 3D sagittal T2WI, 3D axial T2WI, 2D sagittal T2WI, and 2D axial T2WI of each patient, respectively. In addition, signal intensity ratios (SIR) were calculated between rectal cancer and obturator internus muscle (background) in all patients after CRT on DWI (b=2,000 mm/s2) and correlated with histopathological regression grade (RG). RESULTS: Tumor delineation was significantly better by 2D T2WI than 3D T2WI both before and after CRT (before CRT: Z=-3.2, p=0.02; after CRT: Z=-4.408, p<0.001; all: Z=-5.192; p<0.001) and was the preferred method, although image quality ratings were not significantly different (3D sagittal: 4.00±0.48; 2D sagittal: 4.03±0.34, p=0.713; 3D axial: 3.85±0.61, 2D axial: 3.78±0.64, p=0.537). Independent t-test showed significantly higher SIR between those with RG 1 or 2 (moderate response: mean score=2.02) and those with RG 3+4 (good response: mean score=0.8) (t=3.044, p=0.011). In those with RG 4 (complete response), SIR of b2000 was 0.946 compared to a 1.41 average of the whole cohort. In two patients, tumor was invisible on b2000 following CRT (RG 3 and 4, respectively). Interobserver agreement was mostly good (κ≥0.6) regarding image quality assessment, except for poor agreement (κ=0.4) in DWI (b2000) between the two less-experienced readers. CONCLUSION: In conclusion, 3D T2WI might be useful for evaluating response to neoadjuvant therapy in a comprehensive, cost-effective protocol, where 2D imaging seems to be preferable. In addition, DWI (b2000) may be beneficial in assessing both the primary and the residual tumor after CRT in rectal cancer and SIR may be helpful in assessing response to CRT.


Assuntos
Adenocarcinoma/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Garantia da Qualidade dos Cuidados de Saúde , Neoplasias Retais/patologia , Adenocarcinoma/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimiorradioterapia Adjuvante , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Neoplasias Retais/terapia , Estudos Retrospectivos , Resultado do Tratamento
5.
Anticancer Res ; 38(1): 427-432, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29277805

RESUMO

BACKGROUND/AIM: Exctracapsular extension (ECE) in prostate cancer has a high impact on treatment decision. MRI might predict presence of ECE non-invasively. PATIENTS AND METHODS: Triplanar T2w-sequences, DWI (diffusion weighted imaging) and DCE (dynamic contrast-enhanced imaging) of 34 patients with PCa were analyzed to prior prostatectomy. Sensitivity (SS) and specificity (SP) of T2w, apparent diffusion coefficient (ADC), plasma flow (PF) and mean transit time (MTT) normalized by PCa/normal tissue ratio for prediction of CI (capsular infiltration)/ECE were determined by area-under-the-receiver-operating-characteristics analysis. RESULTS: SS/SP for detecting ECE was 29/85. AUC (area under the curve) of ECE cases was 0.98/0.92/0.69 (cut-off-ratios 3.2/0.51/0.46), SS 93/100/86% and SP 95/80/50% for PF-/MTT-/ADC-ratios, respectively. PF- and MTT-ratios between CI and without CI/ECE differed significantly (PF, p<0.0001; MTT, p=0.0134) with SS/SP 84/89% for PF and SS/SP 52/100% for MTT-ratios. No significant differences regarding ADC-ratios were identified. CONCLUSION: ECE/CI can be assessed by quantitative DCE analysis with great diagnostic confidence and higher specificity than ADC.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Prostatectomia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/patologia , Próstata/cirurgia , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
6.
Diving Hyperb Med ; 42(3): 146-50, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22987461

RESUMO

INTRODUCTION: A vascular right-to-left shunt (r/l shunt) is a well-known risk factor for the development of decompression sickness (DCS). No studies to date have examined whether divers with a history of DCS with or without a r/l shunt have a reduced risk of suffering recurrent DCS when diving more conservative dive profiles (CDP). METHODS: Twenty-seven divers with a history of DCS recommended previously to dive more conservatively were included in this study and retrospectively interviewed by phone to determine the incidence of DCS recurrence. RESULTS: Twenty-seven divers performed 17,851 dives before examination in our department and 9,236 after recommendations for conservative diving. Mean follow up was 5.3 years (range 0-11 years). Thirty-eight events of DCS occurred in total, 34 before and four after recommendation of CDP. Four divers had a closure of their patent foramen ovale (PFO). A highly significant reduction of DCS risk was observed after recommendation of CDP for the whole group as well as for the sub-groups with or without a r/l shunt. A significant reduction of DCS risk in respect to r/l shunt size was also observed. DISCUSSION: This study indicates that recommendations to reduce nitrogen load after DCS appear to reduce the risk of developing subsequent DCS. This finding is independent of whether the divers have a r/l shunt or of shunt size. The risk of suffering recurrent DCS after recommendation for CDP is less than or equal to an unselected cohort of divers. CONCLUSION: Recommendation for CDP seems to significantly reduce the risk of recurrent DCS.


Assuntos
Doença da Descompressão/prevenção & controle , Mergulho/estatística & dados numéricos , Fidelidade a Diretrizes , Comunicação Interatrial/complicações , Adulto , Idoso , Descompressão , Doença da Descompressão/epidemiologia , Doença da Descompressão/etiologia , Feminino , Seguimentos , Fidelidade a Diretrizes/estatística & dados numéricos , Comunicação Interatrial/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Nitrogênio/administração & dosagem , Estudos Retrospectivos , Risco , Gestão de Riscos , Prevenção Secundária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA