Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 24(12): 1917-1925, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36026521

RESUMO

AIMS: Pulmonary vein isolation (PVI) either by balloon devices or radiofrequency forms the cornerstone of invasive atrial fibrillation (AF) treatment. Although equally effective cryoballoon (CB)-based PVI offers shorter procedure duration and a better safety profile. Beside the worldwide established Arctic Front Advance system, a novel CB device, POLARx, was recently introduced. This CB incorporates unique features, which may translate into improved efficacy and safety. However, multicentre assessment of periprocedural efficacy and safety is lacking up to date. METHODS AND RESULTS: A total of 317 patients with paroxysmal or persistent AF were included and underwent POLARx CB-based PVI in 6 centres from Germany and Italy. Acute efficacy and safety were assessed in this prospective multicenter observational study. In 317 patients [mean age: 64 ± 12 years, 209 of 317 (66%) paroxysmal AF], a total of 1256 pulmonary veins (PVs) were identified and 1252 (99,7%) PVs were successfully isolated utilizing mainly the short tip POLARx CB (82%). The mean minimal CB temperature was -57.9 ± 7°C. Real-time PVI was registered in 72% of PVs. The rate of serious adverse events was 6.0% which was significantly reduced after a learning curve of 25 cases (9.3% vs. 3.0%, P = 0.018). The rate of recurrence-free survival after mean follow-up of 226 ± 115 days including a 90-day blanking period was 86.1%. CONCLUSION: In this large multicentre assessment, the novel POLARx CB shows a promising efficacy and safety profile after a short learning curve.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia
2.
Circ Cardiovasc Interv ; 8(7): e002474, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26156150

RESUMO

BACKGROUND: Renal denervation is a new treatment considered for several possible indications. As new systems are introduced, the incidence of acute renal artery wall injury with relation to the denervation method is unknown. We investigated the acute repercussion of renal denervation on the renal arteries of patients treated with balloon-based and nonballoon-based denervation systems by quantitative angiography, intravascular ultrasound, and optical coherence tomography (OCT). METHODS AND RESULTS: Twenty-five patients (50 renal arteries) underwent bilateral renal denervation with 5 different systems, 3 of which balloon-based (Paradise [n=5], Oneshot [n=6], and Vessix V2 [n=5)]) and 2 nonballoon-based (Symplicity [n=6] and EnligHTN [n=3]). Analysis included quantitative angiography and morphometric intravascular ultrasound measurements pre and post procedure and assessment of vascular trauma (dissection, edema, or thrombus) by OCT after denervation. A significant reduction in lumen size by quantitative angiography and intravascular ultrasound was observed in nonballoon denervation but not in balloon denervation. By postdenervation OCT, dissection was seen in 14 arteries (32.6%). The percentage of frames with dissection was higher in balloon-based denervation catheters. Thrombus and edema were detected in 35 (81.4%) and 32 (74.4%) arteries, respectively. In arteries treated with balloon-based denervation that had dissection by OCT, the balloon/artery ratio was higher (1.24 [1.17-1.32] versus 1.10 [1.04-1.18]; P<0.01). CONCLUSIONS: A varying extent of vascular injury was observed after renal denervation in all systems; however, different patterns were identified in balloon-based and in nonballoon-based denervation systems. In balloon denervation, the presence of dissections by OCT was associated with a higher balloon/artery ratio.


Assuntos
Cateterismo Periférico/efeitos adversos , Imagem Multimodal , Artéria Renal/inervação , Simpatectomia/métodos , Lesões do Sistema Vascular/diagnóstico , Idoso , Angiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Lesões do Sistema Vascular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA