RESUMO
BACKGROUND: A limitation associated with coronary computed tomography angiography (CCTA) is the lack of a normal reference value for aortic root dimensions and the uncertainty of the influence of age and gender on these dimensions. The purpose of the present study was to identify the normal values and variations of aortic root dimensions in healthy individuals and investigate how gender and age affect aortic root size. METHODS: A total of 1286 healthy yellow population (52.7 ± 11.0 years, 634 male) who underwent CCTA were retrospectively included in the present study. Male and female patients were divided into seven groups according to age (< 30 years old, 30-39, 40-49, 50-59, 60-69, 70-79, ≥ 80 years old). In these age groups, we measured and compared the parameters of the aortic root. RESULTS: After body surface area (BSA) correction, the aortic root parameters of females were found to be greater than those of males in the 40-49 age group (P<0.05). There were no significant differences in aortic root parameters between genders in other age groups, except for the diameter of the ascending aorta, which was greater in females (P<0.05). In males, age was positively correlated with aortic root parameters (P<0.05), except for the annulus short diameter and LVOT short diameter. In females, age was positively correlated with aortic root parameters (P<0.05), except for the left coronary ostia height and the LVOT short diameter. CONCLUSION: Aortic root dimensions are affected by age and gender. After BSA correction, females show larger aortic root dimensions than males, and aortic root diameters increase with age.
RESUMO
PURPOSE: To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. MATERIALS AND METHODS: This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. RESULTS: A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P < .01 for all). For stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P < .01 for all). There were no significant differences between stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). CONCLUSION: The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter.