RESUMO
Background: The Southeast European (SEE) region of 10 countries and about 43 million people differs from Western Europe in that most SEE countries lack active cancer registries and have fewer diagnostic imaging devices and radiotherapy (RT) units. The main objective of this research is to initiate a common platform for gathering SEE regional cancer data from the ground up to help these countries develop common cancer management strategies. Methods: To obtain detailed on-the-ground information, we developed separate questionnaires for two SEE groups: a) ONCO - oncologists regarding cancer treatment modalities and the availability of diagnostic imaging and radiotherapy equipment; and b) REG - national radiation protection and safety regulatory bodies regarding diagnostic imaging and radiotherapy equipment in SEE facilities. Results: Based on responses from 13/17 ONCO participants (at least one from each country) and from 9/10 REG participants (all countries but Albania), cancer incidence rates are higher in those SEE countries that have greater access to diagnostic imaging equipment while cancer mortality-to-incidence (MIR) ratios are higher in countries that lack radiotherapy equipment. Conclusion: By combining unique SEE region information with data available from major global databases, we demonstrated that the availability of diagnostic imaging and radiotherapy equipment in the SEE countries is related to their economic development. While immediate diagnostic imaging and radiation therapy capacity building is necessary, it is also essential to develop both national and SEE-regional cancer registries in order to understand the heterogeneity of each country's needs and to establish regional collaborative strategies for combating cancer.
RESUMO
PURPOSE: To evaluate a commercially available Ferrous-Xylenol Orange-Gel (FXG) dosimeter (TrueView™) coupled with Optical-Computed Tomography (OCT) read out, for 3D dose verification in an Ir-192 superficial brachytherapy application. METHODS: Two identical polyethylene containers filled with gel from the same batch were used. One was irradiated with an 18â¯MeV electron field to examine the dose-response linearity and obtain a calibration curve. A flap surface applicator was attached to the other to simulate treatment of a skin lesion. The dose distribution in the experimental set up was calculated with the TG-43 and the model based dose calculation (MBCA) algorithms of a commercial treatment planning system (TPS), as well as Monte Carlo (MC) simulation using the MCNP code. Measured and calculated dose distributions were spatially registered and compared. RESULTS: Apart from a region close to the container's neck, where gel measurements exhibited an over-response relative to MC calculations (probably due to stray light perturbation), an excellent agreement was observed between measurements and simulations. More than 97% of points within the 10% isodose line (80â¯cGy) met the gamma index criteria established from uncertainty analysis (5%/2â¯mm). The corresponding passing rates for the comparison of experiment to calculations using the TG-43 and MBDCA options of the TPS were 57% and 92%, respectively. CONCLUSION: TrueView™ is suitable for the quality assurance of demanding radiotherapy applications. Experimental results of this work confirm the advantage of the studied MBDCA over TG-43, expected from the improved account of scatter radiation in the treatment geometry.