Head Face Med ; 20(1): 33, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760840

RESUMO

BACKGROUND: Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS: Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS: The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS: The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Estudos Retrospectivos , Cuidados Pré-Operatórios/métodos , Implantação Dentária/métodos , Adulto Jovem , Implantes Dentários , Implantação Dentária Endóssea/métodos
2.
J Dent Sci ; 18(3): 1227-1234, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37404638

RESUMO

Background/purpose: Immediate implant placement in the mandibular anterior tooth region requires a thorough understanding of the alveolar bone anatomy for determining the ideal implant position and preventing labial bone perforation. The anatomical characteristics of the jaws are closely related to the sagittal root position (SRP) and labial concavity of the alveolar bone. This study evaluated SRP, labial concavity, and labial bone perforation in the mandibular anterior tooth region. Materials and methods: Cone-beam computed tomography images of 116 participants (696 teeth) were uploaded to medical imaging software. SRP classification, labial concavity of the alveolar bone, and labial bone perforation were analyzed. A t-test was performed to compare measurements between the central and lateral incisors, central incisors and canines, and lateral incisors and canines. Results: The results revealed that the frequency of SRP Class I (88.20%) was the highest, and that of SRP Class III was the lowest (0.53%). Central incisors had the highest mean labial concavity (144.5°), followed by the canines (143.9°) and lateral incisors (143.3°), and the differences were significant between any two of the tooth groups (all P < 0.05). The frequency distribution of labial bone perforation was the highest in central incisors (69.9%), followed by the canines (40.5%) and lateral incisors (10.8%). Conclusion: The majority of mandibular anterior teeth had SRP Class I, with Class III being the least prevalent. Central incisors had the highest mean alveolar bone concavity angle and the most frequent labial bone perforations.

3.
Artigo em Inglês | MEDLINE | ID: mdl-35162090

RESUMO

The information on the outpatient expenditure of patients with oromaxillofacial cancer is minimal. This study aimed to compare the average annual expenditure on dental treatment for these patients 5 years before and 5 years after oromaxillofacial cancer diagnosis. In this study, 7731 patients who received oromaxillofacial cancer diagnosis in 2005 were selected from the Registry of Catastrophic Illness Database as the case-cohort. In the control cohort, 38,655 people without cancer were selected from the National Health Insurance Research Database, with the case-control ratio being 1:5. All participants were observed for 5 years before diagnosis and 5 years after diagnosis. The conditional logistic regression model was used to determine the odds ratios of annual expenditures incurred by participants in the case-cohort. The measurement results indicated that in the oromaxillofacial cancer cohort, the average annual dental expenditure levels at 1, 2, 3, 4, and 5 years after diagnosis were US $97.34, US $77.23, US $109.65, US $128.43, and US $128.03 and those at these years before diagnosis were US $37.52, US $32.10, US $31.86, US $29.14, and US $29.35, respectively. In conclusion, the average annual expenditure on the dental treatment of oromaxillofacial cancer patients after five years of diagnosis was increased compared to five years before diagnosis.


Assuntos
Gastos em Saúde , Neoplasias , Estudos de Coortes , Assistência Odontológica , Humanos , Pacientes Ambulatoriais , Taiwan/epidemiologia
4.
Tomography ; 7(2): 219-227, 2021 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-34072906

RESUMO

The retromolar canal is an anatomical variation that occurs in the mandibular bone. The retromolar canal typically originates in the mandibular canal on the distal side of the third molar and extends forward and upward to the retromolar foramen (RMF), which contains the neurovascular bundle. Accidentally damaging the neurovascular bundle in the retromolar canal during the extraction of the third molar, dental implant surgery, or maxillofacial orthognathic surgery may lead to subsequent complications such as incomplete local anesthesia, paresthesia, and bleeding during operation. The objective of this study was to investigate the prevalence of the RMF in the Taiwanese population in a medical center by using dental cone-beam computed tomography (CBCT) and to identify the position of the RMF in the mandibular bone. The dental CBCT images for the mandibular bone of 68 hemi-mandible were uploaded to the medical imaging software Mimics 15.1 to determine the prevalence of the RMF in the Taiwanese population and the three positional parameters of the RMF in the mandibular bone: (1) The diameter of the RMF, (2) the horizontal distance from the midpoint of the RMF to the distal cementoenamel junction of the second molar, and (3) the vertical distance from the midpoint of the RMF to the upper border of the mandibular canal. Seven RMFs were observed in the 68 hemi-mandibles. Thus, the RMF prevalence was 10.3%. In addition, the diameter of the RMF was 1.41 ± 0.30 mm (mean ± standard deviation), the horizontal distance from the midpoint of the RMF to the distal cementoenamel junction of the the second molar was 12.93 ± 2.87 mm, and the vertical distance from the midpoint of the RMF to the upper border of the mandibular canal below second molar was 13.62 ± 1.3487 mm. This study determined the prevalence of the RMF in the Taiwanese population in a medical center and its relative position in the mandibular bone. This information can provide clinicians with a reference for posterior mandible anesthesia and surgery to ensure medical safety.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dente Serotino , Estudos Transversais , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Taiwan
5.
Health Phys ; 112(5): 470-477, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28350702

RESUMO

Reference phantoms are widely applied to evaluate the radiation dose for external exposure. However, the frequently used reference phantoms are based on Caucasians. Dose estimation for Asians using a Caucasian phantom can result in significant errors. This study recruited 40 volunteers whose body sizes are close to the average Taiwanese population. Magnetic resonance imaging was performed to obtain the organ volume for construction of the Taiwanese reference man (TRM) and Taiwanese reference woman (TRW). The dose conversion coefficients (DCC) resulting from photo beams in anterior-posterior, posterior-anterior, right-lateral, left-lateral, and isotropic irradiation geometries were estimated. In the anterior-posterior geometry, the mean DCC differences among organs between the TRM and ORNL phantom at 0.1, 1, and 10 MeV were 7.3%, 5.8%, and 5.2%, respectively. For the TRW, the mean differences from the ORNL phantom at the three energies were 10.6%, 7.4%, and 8.3%. The DCCs of the Taiwanese reference phantoms and the ORNL phantom presented similar trends in other geometries. The torso size of the phantom and the mass and geometric location of the organ have a significant influence on the DCC. The Taiwanese reference phantoms can be used to establish dose guidelines and regulations for radiation protection from external exposure.


Assuntos
Modelos Biológicos , Modelos Estatísticos , Método de Monte Carlo , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Adulto , Biomimética/normas , Simulação por Computador , Feminino , Humanos , Masculino , Doses de Radiação , Proteção Radiológica/normas , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taiwan
6.
J Biomech ; 46(15): 2611-8, 2013 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-24011361

RESUMO

This study compared the capabilities of micro-computed tomography (micro-CT) and dental cone-beam computed tomography (CBCT) in assessing trabecular bone parameters and cortical bone strength. Micro-CT and CBCT scans were applied to 28 femurs from 14 rats to obtain independent measurements of the volumetric cancellous bone mineral density (vCanBMD) in the femoral head, volumetric cortical bone mineral density (vCtBMD) in the femoral diaphysis, cross-sectional moment of inertia (CSMI), and bone strength index (BSI) (=CSMI×vCtBMD). Five structural parameters of the trabecular bone of the femoral head were calculated from micro-CT images. A three-point bending test was then conducted to measure the fracture load of each femur. Bivariate linear Pearson analysis was conducted to calculate the correlation coefficients (r values) of the micro-CT, dental CBCT, and three-point bending measurements. The statistical analyses showed a strong correlation between vCanBMD values obtained using micro-CT and dental CBCT (r=0.830). There were strong or moderate correlation between vCanBMD measured using dental CBCT and five parameters of trabecular structure measured using micro-CT. Additionally, the results were satisfactory regardless of whether micro-CT or dental CBCT was used to measure the femoral diaphysis vCtBMD (r=0.733 and 0.680, respectively), CSMI (r=0.756 and 0.726, respectively), or BSI (r=0.846 and 0.847, respectively) to predict fracture loads. This study has yielded a new method for using dental CBCT to evaluate bone parameters and bone strength; however, further studies are necessary to validate the use of dental CBCT on humans.


Assuntos
Fraturas do Fêmur , Fêmur , Modelos Biológicos , Microtomografia por Raio-X , Animais , Diáfises , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/fisiopatologia , Fêmur/diagnóstico por imagem , Fêmur/fisiopatologia , Humanos , Masculino , Ratos , Ratos Sprague-Dawley , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA