Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur Radiol ; 33(3): 1769-1778, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36370173

RESUMO

OBJECTIVE: To assess the risk of cancer induced by diagnostic X-ray exposure in multiple radiological examinations and to explore the relevant influences to provide a reference for rational usage of X-ray examinations. METHODS: Data for all adult patients who underwent X-ray examinations from August 2004 to April 2020 in a general hospital was collected, including sex, age, primary diagnosis, and X-ray examination. Based on the Biological Effects of Ionizing Radiations report, age and sex and effective dose for a single X-ray examination were used to calculate the lifetime attributable risk (LAR). Patients whose cancer LAR values were in the top 5% were considered to have a high cancer risk; the factors influencing this status were explored by using multivariate logistic regression analyses. RESULTS: In total, 1,143,413 patients with 3,301,286 X-ray examinations were included. LARs of cancer incidence and death were < 0.2% and < 0.13% among 95% of patients and they were > 1% among 0.21% and 0.07% of patients. High risks of incidence and death were significantly associated with corrected exposure frequency (odds ratio [OR], 1.080 and 1.080), sex (OR, male vs. female, 0.421 and 0.372), and year of birth (OR, 1.088 and 1.054), with all p values < 0.001. Among 20 disease categories, congenital disease (OR, 3.792 and 4.024), genitourinary disease (OR, 3.608 and 3.202), digestive disease (OR, 3.247 and 3.272), and tumor disease (OR, 2.706 and 2.767) had the strongest associations with high risks of incidence and death (all p values < 0.001). CONCLUSIONS: Cancer risk induced by diagnostic X-ray examinations can be considered acceptable clinically. Patients having certain diseases are potentially at a relative higher risk due to recurrent examinations. KEY POINTS: • It was the first large-scale investigation of cumulative X-ray exposure in China, involving more than 3.3 million X-ray scans of all types of diagnostic X-ray examinations for about 1.1 million patients during the past 16 years. • The study revealed that the incidence risk of cancer induced by X-ray-related examinations was 0.01% on average, which was substantially lower than that of cancer induced by non-X-ray radiation. The risk could be considered acceptable clinically. • Patients having certain diseases were potentially at a relatively higher cancer risk due to recurrent X-ray examinations. The cumulative effect of X-ray exposure could not be ignored and was worthy of attention.


Assuntos
Neoplasias Induzidas por Radiação , Adulto , Humanos , Masculino , Feminino , Estudos de Coortes , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Radiografia , Fatores de Risco , Incidência , Doses de Radiação , Medição de Risco
2.
Front Oncol ; 12: 849368, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387122

RESUMO

Objectives: Upper gastrointestinal (G.I.) cancer screening has been conducted in China for decades. However, the economic burden for treatment "intensively" occurred in advance due to screening in resource-limited communities remain unclear. Methods: We compared the treatment costs for upper G.I. cancers from the screening and control arms of a population-based randomized trial in a high-risk area for esophageal cancer (EC) in China based on claims data from the health insurance system in the local area which included whole population coverage. Results: The average out-of-pocket cost per treatment of EC in the screening arm was lower than that in the control arm ($5,972 vs. $7,557). This difference was a consequence of down-staging from screening which resulted in lower cost therapy for earlier stage cancers. Moreover, this result is similar for cardial and non-cardial gastric cancer in the two study arms ($7,933 vs. $10,605). However, three times as many (103 vs. 36) families in the screening arm suffered catastrophic health expenditure for all cancer types. The overall treatment cost for all EC patients in the screening arm ($1,045,119) was 2.44 times that in the control arm ($428,292), and the ratio for cardial and non-cardial gastric cancer was 1.12 ($393,261 vs. $351,557). Conclusion: Cancer treatment secondary to screening may triple the likelihood of catastrophic patient medical expenditure, and sharply increase the economic pressure on the local community, particularly for cancer types which are of high prevalence. Financial support for patients and the health insurance system should be taken into consideration when planning budgets for cancer screening programs in communities which are resource-limited.

3.
J Surg Res ; 247: 356-363, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31679801

RESUMO

BACKGROUND: Currently, very limited information is available regarding the economic burdens of patients with extremity post-traumatic osteomyelitis (OM). This study aimed to investigate direct health care costs and utilization for inpatients with extremity post-traumatic OM and analyze its constituent ratios and influencing factors in Southern China. METHODS: We searched in the electronic medical record system for inpatients who had received surgical interventions at our department between 2013 and 2016 for extremity post-traumatic OM. Data of direct health care costs incurred during their hospitalizations were collected in six main categories (service, diagnosis, treatment, materials, pharmaceuticals, and miscellaneous expenses). In addition, data of total medical costs for contemporaneous inpatients with non-post-traumatic OM were also collected as controls. RESULTS: A total of 278 post-traumatic OM and 10,420 controls were included. The median cost for the post-traumatic OM inpatients was $10,504 US dollars, 4.8-fold higher than that for those with non-post-traumatic OM ($2189, P < 0.001). The direct cost in the category of materials accounted for the largest proportion (61%), followed by that in pharmaceuticals (12%) and treatment (11%). The median number of hospital admissions for post-traumatic OM patients was 1 time, with a median length-of-stay of 22 d. The most influencing factors for the health care costs of the post-traumatic OM inpatients were use of an external fixator ($16,016 for those who used versus $4956 for those who did not, P < 0.001), external fixator type ($19,563 for ring fixator versus $14,966 for rail fixator, P < 0.001), infection site ($13,755 for tibia, $14,216 for femur and $5673 for calcaneus, P < 0.001), and infection-associated injury type ($12,890 for infection after open fracture versus $8087 for infection after closed fracture, P = 0.001). CONCLUSIONS: An unexpectedly large proportion of the direct health care costs for inpatients with extremity post-traumatic OM went to cover an external fixator, with expenses for pharmaceuticals and treatment accounting for only a little more than the tenth of the total health care costs. Use of external fixator, external fixator type, infection site, and infection-associated injury type directly influenced the health care costs.


Assuntos
Efeitos Psicossociais da Doença , Fraturas Ósseas/complicações , Custos de Cuidados de Saúde/estatística & dados numéricos , Hospitalização/economia , Osteomielite/economia , Adulto , China , Fixadores Externos/economia , Fixadores Externos/estatística & dados numéricos , Extremidades/lesões , Feminino , Fraturas Ósseas/economia , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Osteomielite/diagnóstico , Osteomielite/etiologia , Osteomielite/terapia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Estudos Retrospectivos , Adulto Jovem
4.
Opt Express ; 26(8): 10152-10161, 2018 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-29715955

RESUMO

A quasi-distributed liquid leakage (QDLL) sensor in local area is proposed and experimentally demonstrated, providing a real-time yet low-cost method than the existing local QDLL sensor. The sensor mainly consists of a flexible lamp belt (FLB) with light-emitting diodes (LEDs) and a polymer optical fiber (POF) processed with side-coupling structures. The side-coupling structures are illuminated by the LEDs one by one, forming a series of sensing probes. The lights are side-coupled into the POF through the side-coupling structure and pulse sequences are obtained from the power meters connected to the both ends of the POF. Each pulse represents a sensing probe, and the intensity of them increase when the coupling medium changes from air to liquid. The location of the leakage incident can be got by the position of each pulse in its output sequence. The influence of different side-coupling structures on side-coupling ratio are investigated. The experiment results validate the detection and localization abilities of the QDLL sensor along a 1 m-long POF with a spatial resolution of 0.1 m, which can be improved by adjusting the side-coupling structure. Furthermore, the temperature dependence is studied and can be compensated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA