Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Stud Health Technol Inform ; 270: 123-127, 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32570359

RESUMO

Iodine-containing contrast agents (CA) are important for enhanced image contrast in CT imaging especially in CT angiography (CTA). CA however poses a risk to the patient since it can e.g. harm the kidneys. In clinical routine often a standard dose is applied that does not take differences between individual patients into account. We propose a method that as a preliminary stage determines excessive image contrast and CA overdosing by assessing the image contrast in CTA images obtained with the ulrich medical CT motion contrast media injector with RIS/PACS interface. A resulting CA dose recommendation is linked to a set of clinical parameters collected for each assessed patient. We used the established data set to implement an automatic classification for individual CA dose adjustment. The classification determines similar cases of new patients to take on the associated CA dose adjustment recommendation. The computation of similar patient data is based on the previously collected patient-individual parameters. The study shows that as basis for a recommendations the largest proportion of patients receive too much CA. A first evaluation of the automatic classification showed an overall error rate of 22% to recognize the correct class for CA dose adjustments using a k-NN-Classifier and a leave-one-out method. The classification's positive predictive value for correctly assigning a CA overdosing was 85.71%.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
2.
Rofo ; 190(4): 348-358, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29495050

RESUMO

PURPOSE: Calculation of process-orientated costs for inpatient endovascular treatment of peripheral artery disease (PAD) from an interventional radiology (IR) perspective. Comparison of revenue situations in consideration of different ways to calculate internal treatment charges (ITCs) and diagnosis-related groups (DRG) for an independent IR department. MATERIALS AND METHODS: Costs (personnel, operating, material, and indirect costs) for endovascular treatment of PAD patients in an inpatient setting were calculated on a full cost basis. These costs were compared to the revenue situation for IR for five different scenarios: 1) IR receives the total DRG amount. IR receives the following DRG shares using ITCs based on InEK shares for 2) "Radiology" cost center type, 3) "OP" cost center type, 4) "Radiology" and "OP" cost center type, and 5) based on DKG-NT (scale of charges of the German Hospital Society). RESULTS: 78 patients (mean age: 68.6 ±â€Š11.4y) with the following DRGs were evaluated: F59A (n = 6), F59B (n = 14), F59C (n = 20) and F59 D (n = 38). The length of stay for these DRG groups was 15.8 ±â€Š12.1, 9.4 ±â€Š7.8, 2.8 ±â€Š3.7 and 3.4 ±â€Š6.5 days Material costs represented the bulk of all costs, especially if new and complex endovascular procedures were performed. Revenues for neither InEK shares nor ITCs based on DKG-NT were high enough to cover material costs. Contribution margins for the five scenarios were 1 = €â€Š1,539.29, 2 = €â€Š-1,775.31, 3 = €â€Š-2,579.41, 4 = €â€Š-963.43, 5 = €â€Š-2,687.22 in F59A, 1 = €â€Š-792.67, 2 = €â€Š-2,685.00, 3 = €â€Š-2,600.81, 4 = €â€Š-1,618.94, 5 = €â€Š-3,060.03 in F59B, 1 = €â€Š-879.87, 2 = €â€Š-2,633.14, 3 = €â€Š-3,001.07, 4 = €â€Š-1,952.33, 5 = €â€Š-3,136.24 in F59C and 1 = €â€Š703.65, 2 = €â€Š-106.35, 3 = €â€Š-773.86, 4 = €â€Š205.14, 5 = €â€Š-647.22 in F59 D. InEK shares return on average €â€Š150 - 500 more than ITCs based on the DKG-NT catalog. CONCLUSION: In this study positive contribution margins were seen only if IR receives the complete DRG amount. InEK shares do not cover incurred costs, with material costs representing the main part of treatment costs. Internal treatment charges based on the DKG-NT catalog provide the worst cost coverage. KEY POINTS: · Internal treatment charges based on the DKG-NT catalog provide the worst cost coverage for interventional radiology at our university hospital.. · Shares from the InEK matrix such as the cost center "radiology" or "OP" as revenue for IR are not sufficient to cover incurred costs. A positive contribution margin is achieved only in the case of a compensation method in which IR receives the total DRG amount.. CITATION FORMAT: · Vogt FM, Hunold P, Haegele J et al. Comparison of the Revenue Situation in Interventional Radiology Based on the Example of Peripheral Artery Disease in the Case of a DRG Payment System and Various Internal Treatment Charges. Fortschr Röntgenstr 2017; 190: 348 - 357.


Assuntos
Grupos Diagnósticos Relacionados/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Preços Hospitalares/estatística & dados numéricos , Reembolso de Seguro de Saúde/economia , Programas Nacionais de Saúde/economia , Doença Arterial Periférica , Radiologia Intervencionista/economia , Angiografia/economia , Custos e Análise de Custo , Alemanha , Humanos , Classificação Internacional de Doenças/economia , Doença Arterial Periférica/economia , Doença Arterial Periférica/terapia , Recursos Humanos em Hospital/economia
3.
Circ Cardiovasc Imaging ; 4(6): 610-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21911738

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) is considered the reference standard for assessment of left ventricular ejection fraction (LVEF) and myocardial damage. However, few studies have evaluated the relationship between CMR findings and patient outcome, and of these, most are small and none multicenter. We performed an international, multicenter study to assess the prognostic importance of routine CMR in patients with known or suspected heart disease. METHODS AND RESULTS: From 10 centers in 6 countries, consecutive patients undergoing routine CMR assessment of LVEF and myocardial damage by cine and delayed-enhancement imaging (DE-CMR), respectively, were screened for enrollment. Clinical data, CMR protocol information, and findings were collected at all sites and submitted to the data coordinating center for verification of completeness and analysis. The primary end point was all-cause mortality. A total of 1560 patients (age, 59±14 years; 70% men) were enrolled. Mean LVEF was 45±18%, and 1049 (67%) patients had hyperenhanced tissue (HE) on DE-CMR indicative of damage. During a median follow-up time of 2.4 years (interquartile range, 1.2, 2.9 years), 176 (11.3%) patients died. Patients who died were more likely to be older (P<0.0001), have coronary disease (P=0.004), have lower LVEF (P<0.0001), and have more segments with HE (P<0.0001). In multivariable analysis, age, LVEF, and number of segments with HE were independent predictors of mortality. Among patients with near-normal LVEF (≥50%), those with above-median HE (>4 segments) had reduced survival compared to patients with below- or at-median HE (P=0.02). CONCLUSIONS: Both LVEF and amount of myocardial damage as assessed by routine CMR are independent predictors of all-cause mortality. Even in patients with near-normal LVEF, significant damage identifies a cohort with a high risk for early mortality.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Volume Sistólico/fisiologia , Adulto , Fatores Etários , Idoso , Distribuição de Qui-Quadrado , Estudos de Coortes , Doença da Artéria Coronariana/mortalidade , Testes Diagnósticos de Rotina , Feminino , Humanos , Cooperação Internacional , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Análise de Sobrevida
4.
Acta Cardiol ; 66(3): 349-57, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21744705

RESUMO

OBJECTIVE: Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). METHODS AND RESULTS: 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). CONCLUSIONS: Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Músculos Papilares/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Diástole/fisiologia , Feminino , Coração/fisiopatologia , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Sístole/fisiologia
5.
Eur J Radiol ; 74(3): 492-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19394783

RESUMO

PURPOSE: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). MATERIALS AND METHODS: 33 consecutive patients were examined on a 1.5T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5m; flip angle (FA), 60 degrees ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. RESULTS: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P<0.001), whereas ejection fraction estimation yielded equivalent results (P>0.121). In both readers and for all parameters variances did not differ significantly (P>or=0.409) and the two approaches showed an excellent linear correlation (r>0.951). CONCLUSION: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Imagem Cinética por Ressonância Magnética/métodos , Mecânica Respiratória , Disfunção Ventricular Esquerda/diagnóstico , Adulto , Idoso , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
6.
Eur J Radiol ; 74(3): 484-91, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19375878

RESUMO

PURPOSE: To quantify left ventricular (LV) function and mass (LVM) derived from dual-source computed tomography (DSCT) and the influence of beta-blocker administration compared to cardiac magnetic resonance imaging (CMR). METHODS: Thirty-two patients undergoing cardiac DSCT and CMR were included, where of fifteen received metoprolol intravenously before DSCT. LV parameters were calculated by the disc-summation method (DSM) and by a segmented region-growing algorithm (RGA). All data sets were analyzed by two blinded observers. Interobserver agreement was tested by the intraclass correlation coefficient. RESULTS.: 1. Using DSM LV parameters were not statistically different between DSCT and CMR in all patients (DSCT vs. CMR: EF 63+/-8% vs. 64+/-8%, p=0.47; EDV 136+/-36 ml vs. 138+/-35 ml, p=0.66; ESV 52+/-21 ml vs. 52+/-22 ml, p=0.61; SV 83+/-22 ml vs. 87+/-19 ml, p=0.22; CO 5.4+/-0.9l/min vs. 5.7+/-1.2l/min, p=0.09, LVM 132+/-33 g vs. 132+/-33 g, p=0.99). 2. In a subgroup of 15 patients beta-blockade prior to DSCT resulted in a lower ejection fraction (EF), stroke volume (SV), cardiac output (CO) and increase in end systolic volume (ESV) in DSCT (EF 59+/-8% vs. 62+/-9%; SV 73+/-17 ml vs. 81+/-15 ml; CO 5.7+/-1.2l/min vs. 5.0+/-0.8 l/min; ESV 52+/-27 ml vs. 57+/-24 ml, all p<0.05). 3. Analyzing the RGA parameters LV volumes were not significantly different compared to DSM, whereas LVM was higher using RGA (177+/-31 g vs. 132+/-33 g, p<0.05). Interobserver agreement was excellent comparing DSM values with best agreement between RGA calculations. CONCLUSION: Left ventricular volumes and mass can reliably be assessed by DSCT compared to CMR. However, beta-blocker administration leads to statistically significant reduced EF, SV and CO, whereas ESV significantly increases. DSCT RGA reliably analyzes LV function, whereas LVM is overestimated compared to DSM.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/tratamento farmacológico , Adulto , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
7.
J Magn Reson Imaging ; 21(4): 376-82, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15779026

RESUMO

PURPOSE: To evaluate the impact of parallel acquisition techniques (PATs) on image quality and detection of liver metastases using three-dimensional volumetric interpolated breath-hold examination (VIBE) for clinical liver imaging. MATERIALS AND METHODS: Forty-nine patients with various primary malignancies underwent abdominal dynamic contrast-enhanced three-dimensional VIBE magnetic resonance imaging (MRI) (1.5 T) using a standard phased array coil. Recently introduced Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) and SENSitivity Encoding (mSENSE) PAT reconstruction algorithms were added to reduce scan time twofold. Overall image quality, motion, and aliasing artifacts were classified on a 5-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were performed for quantitative comparison. All sequences were evaluated concerning the number of detected lesions. RESULTS: PAT resulted in a reduction of data acquisition time from 23 to 13 seconds. Both GRAPPA and mSENSE data sets yielded 30% less SNR (34.8 +/- 14.1 and 33.1 +/- 13.3, P < 0.001) and 35% less CNR (21.2 +/- 15.0 and 20.9 +/- 12.7, P < 0.05) in comparison to unaccelerated VIBE (SNR = 50.8 +/- 20.3/CNR = 32.5 +/- 19.1). Similarly, PAT revealed lower-image-quality scores than unaccelerated VIBE. GRAPPA resulted in more fold-over artifacts than mSENSE. mSENSE revealed slightly fewer motion artifacts than no PAT. The unaccelerated late-venous-phase VIBE sequence revealed 146 lesions in the same patients. Accelerated images with mSENSE reconstruction detected 138 lesions. GRAPPA revealed 127 lesions, and thus performed inferior to mSENSE. CONCLUSION: At least for arrays with small numbers of elements, such as arrays used in this study, the PAT-induced reduction in scanning times must be weighed against compromises in image quality, which translate into poorer diagnostic performance regarding detection of small hepatic lesions. Thus, the PAT implementations tested in this study should probably be reserved for patients unable to hold their breaths for regular three-dimensional VIBE data sets.


Assuntos
Abdome , Imageamento por Ressonância Magnética/métodos , Neoplasias Abdominais/diagnóstico , Algoritmos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Respiração
8.
AJR Am J Roentgenol ; 184(3): 765-73, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15728595

RESUMO

OBJECTIVE: The purpose of our study was to quantify left ventricular function and mass derived from retrospectively ECG-gated 16-MDCT coronary angiography data sets using a new analysis software based on automatic contour detection in comparison to corresponding standard of reference measurements acquired with MRI. SUBJECTS AND METHODS: Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 18 patients (men, 15; women, three; age range, 38-70 years; mean, 57.4 +/- 10.2 [SD] years) who were referred for CT coronary angiography. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed with a recently developed imaging software using an automated contour detection algorithm of left ventricular endo- and epicardial contours and by manual tracing. The data were compared with similar measurements on MRI as the standard of reference. RESULTS: EDV, ESV, EF, and LVM derived from an automated contour detection algorithm were not statistically significantly different from manual tracing (CT(auto) vs CT(manual): EDV = 137.1 +/- 45.7 mL vs 134.2 +/- 39.9 mL, ESV = 58.8 +/- 34.2 mL vs 58.1 +/-30.1 mL, EF = 59.2% +/- 13.7% vs 58.1% +/- 12.0%, LVM = 130.9 +/- 29.1 g vs 133.7 +/- 33.2 g; p > 0.05). However, EDV (118.7 +/- 43.6 mL), ESV (50.1 +/- 33.5 mL), and LVM (142.8 +/-38.4 g) as calculated on MR data sets were statistically significantly different from those calculated on CT (p < 0.05), whereas MRI-based EF (59.9% +/- 14.4%) did not differ statistically significantly from those based on both CT algorithms (p > 0.05). CONCLUSION: Automatic and manual analysis of data acquired during CT coronary angiography using a 16-MDCT scanner allows a reliable assessment of left ventricular ejection fraction and a rough estimation of left ventricular volumes and mass.


Assuntos
Angiografia Coronária/métodos , Endocárdio/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Software , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Endocárdio/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Pericárdio/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA