Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cancers (Basel) ; 15(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36831368

RESUMO

Early assessment of neoadjuvant systemic therapy (NAST) response for triple-negative breast cancer (TNBC) is critical for patient care in order to avoid the unnecessary toxicity of an ineffective treatment. We assessed functional tumor volumes (FTVs) from dynamic contrast-enhanced (DCE) MRI after 2 cycles (C2) and 4 cycles (C4) of NAST as predictors of response in TNBC. A group of 100 patients with stage I-III TNBC who underwent DCE MRI at baseline, C2, and C4 were included in this study. Tumors were segmented on DCE images of 1 min and 2.5 min post-injection. FTVs were measured using the optimized percentage enhancement (PE) and signal enhancement ratio (SER) thresholds. The Mann-Whitney test was used to compare the performance of the FTVs at C2 and C4. Of the 100 patients, 49 (49%) had a pathologic complete response (pCR) and 51 (51%) had a non-pCR. The maximum area under the receiving operating characteristic curve (AUC) for predicting the treatment response was 0.84 (p < 0.001) for FTV at C4 followed by FTV at C2 (AUC = 0.82, p < 0.001). The FTV measured at baseline was not able to discriminate pCR from non-pCR. FTVs measured on DCE MRI at C2, as well as at C4, of NAST can potentially predict pCR and non-pCR in TNBC patients.

2.
Radiol Imaging Cancer ; 3(5): e200155, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34477453

RESUMO

Purpose To determine if amide proton transfer-weighted chemical exchange saturation transfer (APTW CEST) MRI is useful in the early assessment of treatment response in persons with triple-negative breast cancer (TNBC). Materials and Methods In this prospective study, a total of 51 participants (mean age, 51 years [range, 26-79 years]) with TNBC were included who underwent APTW CEST MRI with 0.9- and 2.0-µT saturation power performed at baseline, after two cycles (C2), and after four cycles (C4) of neoadjuvant systemic therapy (NAST). Imaging was performed between January 31, 2019, and November 11, 2019, and was a part of a clinical trial (registry number NCT02744053). CEST MR images were analyzed using two methods-magnetic transfer ratio asymmetry (MTRasym) and Lorentzian line shape fitting. The APTW CEST signals at baseline, C2, and C4 were compared for 51 participants to evaluate the saturation power levels and analysis methods. The APTW CEST signals and their changes during NAST were then compared for the 26 participants with pathology reports for treatment response assessment. Results A significant APTW CEST signal decrease was observed during NAST when acquisition at 0.9-µT saturation power was paired with Lorentzian line shape fitting analysis and when the acquisition at 2.0 µT was paired with MTRasym analysis. Using 0.9-µT saturation power and Lorentzian line shape fitting, the APTW CEST signal at C2 was significantly different from baseline in participants with pathologic complete response (pCR) (3.19% vs 2.43%; P = .03) but not with non-pCR (2.76% vs 2.50%; P > .05). The APTW CEST signal change was not significant between pCR and non-pCR at all time points. Conclusion Quantitative APTW CEST MRI depended on optimizing acquisition saturation powers and analysis methods. APTW CEST MRI monitored treatment effects but did not differentiate participants with TNBC who had pCR from those with non-pCR. © RSNA, 2021 Clinical trial registration no. NCT02744053 Supplemental material is available for this article.Keywords Molecular Imaging-Cancer, Molecular Imaging-Clinical Translation, MR-Imaging, Breast, Technical Aspects, Tumor Response, Technology Assessment.


Assuntos
Prótons , Neoplasias de Mama Triplo Negativas , Amidas , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Terapia Neoadjuvante , Projetos Piloto , Estudos Prospectivos , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem
3.
J Magn Reson Imaging ; 15(1): 55-61, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11793457

RESUMO

PURPOSE: To minimize contrast agent dosage for intra-arterial (IA) contrast-enhanced magnetic resonance angiography (CE-MRA) by examining the effects of encoding order (elliptical vs. sequential) and injection duration (100% to 30% of the acquisition time). MATERIALS AND METHODS: Catheter-based IA gadolinium (Gd) injections were performed in an arterial flow phantom. Blood flow rates, injection rates, and injection durations were systematically varied. Signal-to-noise (SNR) measurements were obtained in the aorta, renal artery, and common iliac artery. RESULTS: No significant SNR losses were observed for any of the vessels with 75% injection duration, or for the aorta and iliac artery with 50% injection duration. Excellent images of all vessels were obtained at 50% injection duration. There was no significant SNR difference between encoding schemes. CONCLUSION: Contrast agent dosage can be substantially reduced without loss of SNR by limiting injection to part of the imaging acquisition time.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio DTPA/administração & dosagem , Angiografia por Ressonância Magnética/métodos , Aorta Abdominal , Velocidade do Fluxo Sanguíneo , Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Artéria Ilíaca , Injeções Intra-Arteriais , Imagens de Fantasmas , Artéria Renal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA