Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Cancers (Basel) ; 14(7)2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35406542

RESUMO

The aims of this systematic review were to (1) assess the utility of PSMA-PET and choline-PET in the assessment of response to systemic and local therapy, and to (2) determine the value of both tracers for the prediction of response to therapy and survival outcomes in prostate cancer. We performed a systematic literature search in PubMed/Scopus/Google Scholar/Cochrane/EMBASE databases (between January 2010 and October 2021) accordingly. The quality of the included studies was evaluated following the "Quality Assessment of Prognostic Accuracy Studies" tool (QUAPAS-2). We selected 40 articles: 23 articles discussed the use of PET imaging with [68Ga]PSMA-11 (16 articles/1123 patients) or [11C]/[18F]Choline (7 articles/356 patients) for the prediction of response to radiotherapy (RT) and survival outcomes. Seven articles (three with [68Ga]PSMA-11, three with [11C]Choline, one with [18F]Choline) assessed the role of PET imaging in the evaluation of response to docetaxel (as neoadjuvant therapy in one study, as first-line therapy in five studies, and as a palliative regimen in one study). Seven papers with radiolabeled [18F]Choline PET/CT (n = 121 patients) and three with [68Ga]PSMA-11 PET (n = 87 patients) were selected before and after enzalutamide/abiraterone acetate. Finally, [18F]Choline and [68Ga]PSMA-11 PET/CT as gatekeepers for the treatment of metastatic prostate cancer with Radium-223 were assessed in three papers. In conclusion, in patients undergoing RT, radiolabeled choline and [68Ga]PSMA-11 have an important prognostic role. In the case of systemic therapies, the role of such new-generation imaging techniques is still controversial without sufficient data, thus requiring additional in this scenario.

3.
J Nucl Med ; 59(4): 691-697, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28970332

RESUMO

Impaired fundic accommodation (FA) limits fundic relaxation and the ability to act as a reservoir for food. Assessing intragastric meal distribution (IMD) during gastric emptying scintigraphy (GES) allows for a simple measure of FA. The 3 goals of this study were to evaluate trained readers' (nuclear medicine and radiology physicians) visual assessments of FA from solid-meal GES; develop software to quantify GES IMD; and correlate symptoms of gastroparesis with IMD and gastric emptying. Methods: After training to achieve a consensus interpretation of GES FA, 4 readers interpreted FA in 148 GES studies from normal volunteers and patients. Mixture distribution and κ-agreement analyses were used to assess reader consistency and agreement of scoring of FA. Semiautomated software was used to quantify IMD (ratio of gastric counts in the proximal stomach to those in the total stomach) at 0, 1, 2, 3, and 4 h after ingestion of a meal. Receiver-operating-characteristic analysis was performed to optimize the diagnosis of abnormal IMD at 0 min (IMD0) with impaired FA. IMD0, GES, water load testing, and symptoms were then compared in 177 patients with symptoms of gastroparesis. Results: Reader pairwise weighted κ-values for the visual assessment of FA averaged 0.43 (moderate agreement) for normal FA versus impaired FA. Readers achieved 84.0% consensus and 85.8% reproducibility in assessing impaired FA. IMD0 based on the division of the stomach into proximal and distal halves averaged 0.809 (SD, 0.083) for normal FA and 0.447 (SD, 0.132) (P < 0.01) for impaired FA. On the basis of receiver-operating-characteristic analysis, the optimal cutoff for IMD0 discrimination of normal FA from impaired FA was 0.568 (sensitivity, 86.7%; specificity, 91.7%). Of 177 patients with symptoms of gastroparesis, 129 (72.9%) had delayed gastric emptying; 25 (14.1%) had abnormal IMD0 Low IMD0 (impaired FA) was associated with increased early satiety (P = 0.02). Conclusion: FA can be assessed visually during routine GES with moderate agreement and high reader consistency. Visual and quantitative assessments of FA during GES can yield additional information on gastric motility to help explain patients' symptoms.


Assuntos
Esvaziamento Gástrico , Gastroparesia/diagnóstico por imagem , Gastroparesia/fisiopatologia , Refeições , Humanos , Processamento de Imagem Assistida por Computador , Cintilografia , Software
5.
AJR Am J Roentgenol ; 209(5): 1136-1142, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28777652

RESUMO

OBJECTIVE: Differences in the attenuation correction methods used in PET/CT scanners versus the newly introduced whole-body simultaneous PET/MRI reportedly result in differences in standardized uptake values (SUVs) in the normal skeleton. The aim of the study was to compare the semiquantitative FDG uptake in the normal skeleton using time-of-flight (TOF) PET/MRI versus PET/CT with and without TOF. SUBJECTS AND METHODS: Participants received a single FDG injection and underwent non-TOF and TOF PET/CT (n = 23) or non-TOF PET/CT and TOF PET/MRI (n = 50). Mean SUV (SUVmean) and maximum SUV (SUVmax) were measured from all PET scans for nine normal regions of the skeleton. Pearson correlation coefficients (r) were used to evaluate the SUVmax and SUVmean of normal skeleton between non-TOF and TOF PET/CT, as well as between non-TOF PET/CT and TOF PET/MRI. In addition, percentage differences in SUVmax and SUVmean of the normal skeleton between non-TOF and TOF PET/CT and between non-TOF PET/CT and TOF PET/MRI were evaluated. RESULTS: The SUVmax and SUVmean in the normal skeleton significantly increased between non-TOF and TOF PET/CT, but they significantly decreased between non-TOF PET/CT and TOF PET/MRI. The SUVmax and SUVmean in normal skeleton showed good correlation between non-TOF PET/CT and TOF PET/MRI (SUVmax, r = 0.88; SUVmean, r = 0.91) and showed a similar trend between non-TOF and TOF PET/CT (SUVmax, r = 0.88; SUVmean, r = 0.94). CONCLUSION: In the normal skeleton, SUVmax and SUVmean showed high correlations between PET/MRI and PET/CT. The MRI attenuation correction used in TOF PET/MRI provides reliable semiquantitative measurements in the normal skeleton.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/metabolismo , Fluordesoxiglucose F18/farmacocinética , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/farmacocinética , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Prospectivos , Imagem Corporal Total
6.
Nucl Med Commun ; 38(4): 325-332, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28230714

RESUMO

PURPOSE: The purpose of this study was to test a method of quantifying skeletal tumour burden with F-NaF PET/CT. PATIENTS AND METHODS: We retrospectively reviewed the charts of 117 patients who underwent F-NaF PET/CT for the detection of bone metastases, 68 women and 49 men, 16-82 years old (mean±SD: 62.9±10.7 years). Mean standardized uptake values (SUVmean) were measured in five anatomic sites to evaluate normal skeleton activity. The influence of sex and age was investigated. Skeletal tumour burden was calculated in 69 exams positive for bone metastases using volumetric data and SUVmean values. Intraobserver and interobserver reproducibility was tested. In 10 patients with breast cancer, skeletal tumour burden in pretreatment and post-treatment F-NaF PET/CT was compared with tumour marker and clinical evolution. RESULTS: The range of normal skeleton SUVmean for the 410 volume of interests analysed was 2.2-5.9 (mean±SD: 4.4±1.5). A threshold of 10 was chosen to exclude F-NaF normal skeleton uptake. An inverse relationship was found between normal skeleton SUVmean and age (r=-0.237; P=0.032). Our results show excellent intraobserver and interobserver reproducibility, with intraclass correlation values of 0.995 and 0.997, respectively. The percentage change in the skeletal tumour burden in response to therapy shows a moderate direct correlation with the percentage variation of the tumour marker (r=0.668; P=0.035). CONCLUSION: The methodology that we used to quantify skeletal tumour burden is easy to perform, highly reproducible and allows for the evaluation of bone tumour response to therapy in a subgroup of breast cancer patients. The possibility of skeletal tumour burden quantification is another advantage of F-NaF PET/CT over the visual and subjective interpretation of bone scintigraphy.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Carga Tumoral , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Feminino , Radioisótopos de Flúor , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Fluoreto de Sódio , Adulto Jovem
8.
Clin Nucl Med ; 40(1): 1-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25489952

RESUMO

PURPOSE: The recent introduction of hybrid PET/MRI scanners in clinical practice has shown promising initial results for several clinical scenarios. However, the first generation of combined PET/MRI lacks time-of-flight (TOF) technology. Here we report the results of the first patients to be scanned on a completely novel fully integrated PET/MRI scanner with TOF. MATERIALS AND METHODS: We analyzed data from patients who underwent a clinically indicated F FDG PET/CT, followed by PET/MRI. Maximum standardized uptake values (SUVmax) were measured from F FDG PET/MRI and F FDG PET/CT for lesions, cerebellum, salivary glands, lungs, aortic arch, liver, spleen, skeletal muscle, and fat. Two experienced radiologists independently reviewed the MR data for image quality. RESULTS: Thirty-six patients (19 men, 17 women, mean [±standard deviation] age of 61 ± 14 years [range: 27-86 years]) with a total of 69 discrete lesions met the inclusion criteria. PET/CT images were acquired at a mean (±standard deviation) of 74 ± 14 minutes (range: 49-100 minutes) after injection of 10 ± 1 mCi (range: 8-12 mCi) of F FDG. PET/MRI scans started at 161 ± 29 minutes (range: 117 - 286 minutes) after the F FDG injection. All lesions identified on PET from PET/CT were also seen on PET from PET/MRI. The mean SUVmax values were higher from PET/MRI than PET/CT for all lesions. No degradation of MR image quality was observed. CONCLUSION: The data obtained so far using this investigational PET/MR system have shown that the TOF PET system is capable of excellent performance during simultaneous PET/MR with routine pulse sequences. MR imaging was not compromised. Comparison of the PET images from PET/CT and PET/MRI show no loss of image quality for the latter. These results support further investigation of this novel fully integrated TOF PET/MRI instrument.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Compostos Radiofarmacêuticos/administração & dosagem , Reprodutibilidade dos Testes
9.
PET Clin ; 7(3): 263-74, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27157457

RESUMO

Diagnostic imaging plays a major role in the evaluation of patients with malignant bone disease. (18)F-Labeled sodium fluoride ((18)F NaF) is a positron-emitting radiopharmaceutical with desirable characteristics (rapid blood clearance and bone uptake) for high-quality functional imaging of the skeleton. In addition to higher sensitivity and specificity, (18)F NaF PET combined with computed tomography (PET/CT) allows for shorter imaging time, thus improving patients' convenience and benefiting the overall workflow of the imaging facility. Although as yet no robust evidence-based data exist, this article summarizes the published data currently available on the role of (18)F NaF PET/CT in the assessment of malignant bone disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA