J Environ Radioact ; 155-156: 105-111, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26942843

RESUMO

The reference level for effective dose due to gamma radiation from building materials and construction products used for dwellings is set to 1 mSv per year (EC, 1996, 1999), (CE, 2014). Given the specific conditions presented by the EC in report 112 (1999) considering building and construction materials, an I-index of 1 may generate an effective dose of 1 mSv per year. This paper presents a comparison of the activity concentrations of (4)(0)K, (226)Ra and (232)Th of aggregates and when these aggregates constitute a part of concrete. The activity concentration assessment tool for building and construction materials, the I-index, introduced by the EC in 1996, is used in the comparison. A comparison of the I-indices values are also made with a recently presented dose model by Hoffman (2014), where density variations of the construction material and thickness of the construction walls within the building are considered. There was a ∼16-19% lower activity index in concretes than in the corresponding aggregates. The model by Hoffman further implies that the differences between the I-indices of aggregates and the concretes' final effective doses are even larger. The difference is due, mainly to a dilution effect of the added cement with low levels of natural radioisotopes, but also to a different and slightly higher subtracted background value (terrestrial value) used in the modeled calculation of the revised I-index by Hoffman (2014). Only very minimal contributions to the annual dose could be related to the water and additives used, due to their very low content of radionuclides reported.


Assuntos
Materiais de Construção/normas , Radioisótopos de Potássio/análise , Monitoramento de Radiação , Rádio (Elemento)/análise , Tório/análise , Raios gama , Modelos Teóricos , Doses de Radiação , Valores de Referência , Espectrometria gama , Suécia
2.
Transbound Emerg Dis ; 63(2): e245-50, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25209697

RESUMO

Newcastle disease virus (NDV), also known as virulent forms of avian paramyxovirus serotype 1 (AMPV-1), is the causative agent of Newcastle disease affecting many species of birds and causing heavy losses to the poultry industry worldwide. Early, rapid and sensitive detection of the viruses or the viral nucleic acids is very important for disease diagnosis and control. This study aimed to evaluate sample preparation under field conditions and the application of a real-time RT-PCR method in the portable T-COR4 platform for the rapid, on-site detection of NDV on a farm. In the laboratory setting, the portable real-time RT-PCR assay had a similar performance compared with that obtained with a larger, stationary Rotor Gene real-time thermocycler. In the field conditions, viral nucleic acids were manually extracted just outside of animal units with minimal equipment and real-time RT-PCR detection was performed with the portable thermocycler T-COR4 placed in a nearby room. The portable assay at the farm detected viral RNA in 15 samples and reached an agreement of 83% (39/47) when the same RNA preparations were tested in the Rotor Gene thermocycler under the laboratory setting. The results demonstrated the feasibility of performing field detection but also the need to improve and further simplify sample preparation procedures.


Assuntos
Doença de Newcastle/diagnóstico , Vírus da Doença de Newcastle/isolamento & purificação , Doenças das Aves Domésticas/diagnóstico , Kit de Reagentes para Diagnóstico/veterinária , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Animais , Estudos de Viabilidade , Doença de Newcastle/virologia , Vírus da Doença de Newcastle/genética , Técnicas de Amplificação de Ácido Nucleico/veterinária , Aves Domésticas , Doenças das Aves Domésticas/virologia , RNA Viral/análise , Kit de Reagentes para Diagnóstico/normas , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária
3.
Radiat Prot Dosimetry ; 144(1-4): 555-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21044997

RESUMO

The measured total efficiency for several source positions has been determined for a large, plastic scintillation detector (NE 102A, 91.5 × 76.0 × 24.5 cm(3)) used for whole-body counting gamma spectrometry. The results have been compared with Monte Carlo-calculated total efficiencies; the code used was MCNPX 2.60. For (137)Cs, there was a good agreement between the measured and calculated total efficiencies. MXNPX was also used to calculate the electron light yield for (137)Cs; for the detector material NE 102A, Birks' constant kB was found to be 9.6 mg cm(-2) MeV(-1). The effect of light losses on spectrum resolution has been investigated for (65)Zn.


Assuntos
Plásticos/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Radiometria/instrumentação , Contagem de Cintilação/instrumentação , Contagem Corporal Total , Calibragem , Radioisótopos de Césio/análise , Elétrons , Humanos , Luz , Modelos Estatísticos , Método de Monte Carlo , Distribuição Normal , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiometria/métodos , Contagem de Cintilação/métodos , Radioisótopos de Zinco/análise
4.
Acta Diabetol ; 40 Suppl 1: S39-44, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14618431

RESUMO

Some elements have toxic effects on the human body and there is thus a need to control their levels in human organs and tissues. Moreover, it is important to increase our knowledge of relationships between observable toxic effects and element concentrations in man and his environment. Monitoring and basic occupational and environmental research rely on measurements directly in humans as well as samples from humans and the environment. This paper reviews recent advances in in vivo X-ray fluorescence methods and their applications.


Assuntos
Doença , Metais/farmacocinética , Humanos , Metais/toxicidade , Método de Monte Carlo , Fótons , Espectrometria por Raios X/métodos , Distribuição Tecidual