1.
Anal Bioanal Chem ; 414(2): 1015-1028, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34750644

RESUMO

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.


Assuntos
Congelamento , Vitamina D/análogos & derivados , Vitamina D/sangue , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodos
2.
Anal Bioanal Chem ; 413(20): 5067-5084, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34184102

RESUMO

An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.


Assuntos
Sociedades Médicas/normas , Vitamina D/análogos & derivados , Vitamina D/química , Humanos , Padrões de Referência , Manejo de Espécimes , Vitamina D/sangue
3.
Epilepsia Open ; 5(1): 73-79, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32140645

RESUMO

OBJECTIVE: Biochemical assessment is recommended for patients prior to initiating and following a ketogenic diet (KD). There is no published literature regarding current practice in the UK and Ireland. We aimed to explore practice in comparison with international guidelines, determine approximate costs of biochemical testing in KD patients across the UK and Ireland, and promote greater consistency in KD services nationally. METHODS: A survey was designed to determine the biochemical tests requested for patients at baseline, 3, 6, 12, 18, and 24 months + on KD. The survey was circulated to 39 centers across the UK and Ireland. RESULTS: Sixteen centers completed the survey. Full blood count, electrolytes, calcium, liver function tests (LFTs), lipid profile, and vitamin D were requested at all centers at baseline, in keeping with international guidelines. Bicarbonate, total protein, and urinalysis were less consistently requested. Magnesium and zinc were requested by all centers, despite not being specifically recommended for pre-diet evaluation in guidelines. Urea and electrolyte profiles and some LFTs were consistently requested at follow-up, in accordance with guidelines. Other LFTs and renal tests, full blood count, lipid profile, acylcarnitine profile, selenium, vitamin D, and urinalysis were less consistently requested at follow-up. The mean costs of the lowest and highest number of tests requested at baseline in our participating centers were £167.54 and £501.93; the mean costs of the lowest and highest number of tests requested at 3-month follow-up were £19.17 and £450.06. SIGNIFICANCE: Biochemical monitoring of KD patients varies widely across the UK and Ireland and does not fully correspond to international best practice guidelines. With an ongoing drive for cost-effectiveness within health care, further work is needed to streamline practice while ensuring patient safety.