Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Japonês | MEDLINE | ID: mdl-30787225

RESUMO

We developed a simplified tool for measuring image quality of medical liquid-crystal displays (LCDs) using a commercially available color digital camera. This tool implemented as a plug-in software for ImageJ (open-source image processing program) was designed to compute modulation transfer functions (MTFs) and Wiener spectra (WS) of monochrome and color LCDs from LCD photographed images captured by a camera. The intensities of the red (R), green (G), and blue (B) signals of the unprocessed image data depend on the spectral sensitivity of the image sensor used in the camera. In order to evaluate image quality based on LCD luminance, the plug-in software calibrates the RGB signals from the camera using measured luminance of the LCD and converts them into grayscale signals that correspond to the luminance of the LCD. The MTFs and WS are determined based on the line response from a one-pixel line image and the one-dimensional noise profiles acquired by scanning the uniform image using numerically synthesized slit, respectively. With this plug-in software for ImageJ, we are able to readily compute MTFs and WS of both monochrome and color LCDs from unprocessed image data of cameras. Our simplified tool is helpful to evaluate and understand the physical performance of LCDs for a large number of display users in hospitals and medical centers.


Assuntos
Apresentação de Dados , Processamento de Imagem Assistida por Computador , Cristais Líquidos , Cor , Software
2.
Ann Nucl Med ; 28(9): 836-50, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25001261

RESUMO

PURPOSE: A recently developed technique which reconstructs quantitative images from original projection data acquired using existing single-photon emission computed tomography (SPECT) devices enabled quantitative assessment of cerebral blood flow (CBF) at rest and after acetazolamide challenge. This study was intended to generate a normal database and to investigate its inter-institutional consistency. METHODS: The three institutions carried out a series of SPECT scanning on 32 healthy volunteers, following a recently proposed method that involved dual administration of (123)I-iodoamphetamine during a single SPECT scan. Intra-institute and inter-institutional variations of regional CBF values were evaluated both at rest and after acetazolamide challenge. Functional images were pooled for both rest and acetazolamide CBF, and inter-institutional difference was evaluated among these images using two independent software programs. RESULTS: Quantitative assessment of CBF images at rest and after acetazolamide was successfully achieved with the given protocol in all institutions. Intra-institutional variation of CBF values at rest and after acetazolamide was consistent with previously reported values. Quantitative CBF values showed no significant difference among institutions in all regions, except for a posterior cerebral artery region after acetazolamide challenge in one institution which employed SPECT device with lowest spatial resolution. Pooled CBF images at rest and after acetazolamide generated using two software programs showed no institutional differences after equalization of the spatial resolution. CONCLUSIONS: SPECT can provide reproducible images from projection data acquired using different SPECT devices. A common database acquired at different institutions may be shared among institutions, if images are reconstructed using a quantitative reconstruction program, and acquired by following a standardized protocol.


Assuntos
Acetazolamida/farmacologia , Encéfalo/efeitos dos fármacos , Encéfalo/diagnóstico por imagem , Fármacos Cardiovasculares/farmacologia , Circulação Cerebrovascular/efeitos dos fármacos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Anfetaminas , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Mapeamento Encefálico , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Descanso , Software
3.
Nucl Med Commun ; 33(4): 371-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22227559

RESUMO

PURPOSE: Intrabullous ventilation in patients with pulmonary emphysema (PE) was cross-sectionally evaluated using dynamic xenon-133 gas single photon emission computed tomography (SPECT). METHODS: Fifty-two patients with PE with a total of 109 bullae of more than 4 cm in maximum diameter underwent xenon-133 gas SPECT. The real xenon-133 gas half-clearance time (T1/2) at each bulla was compared with that at the surrounding lung in the same lobe. The emphysema subtype of the surrounding lung was classified into centrilobular, panlobular, and paraseptal on computed tomography (CT). RESULTS: All bullae except for one in all patients showed xenon-133 gas wash-in. Of the 108 bullae with wash-in, 95 (87.9%) bullae in 46 (88%) patients showed marked xenon-133 gas retention with a T1/2 beyond 110 s (mean: 184 s ± 91). The surrounding lungs of these bullae also showed marked retention with a T1/2 of greater than 100 s (mean: 174 s ± 82), and the majority (N=92, 96.8%) were centrilobular or panlobular on CT. The remaining 13 (12.0%) bullae in six (11%) patients showed minimal retention with a T1/2 of less than 80 s (mean: 62 s ± 11), regardless of no significant difference in size compared with the bullae with marked retention. All the surrounding lungs of these bullae except for one also showed minimal retention with a T1/2 of less than 70 s (mean: 60 s ± 18), which was significantly less compared with that of the bullae with marked retention (P<0.0001), and the majority (N=11, 84.6%) were paraseptal with or without an interstitially fibrotic change and predominantly located at the lower lung lobe on CT. The T1/2 of the 108 bullae with xenon-133 gas wash-in was significantly correlated with that of the surrounding lungs (r=0.884, P<0.0001). CONCLUSION: Intrabullous ventilation in patients with PE appears to depend on the ventilation status of the surrounding lung, and bullae with the surrounding lungs of paraseptal-type emphysema tend to show minimal air trapping. Xenon-133 gas SPECT is useful for assessment of the interaction between intrabullous and surrounding lung's ventilation, which is difficult on CT.


Assuntos
Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ventilação Pulmonar , Tomografia Computadorizada por Raios X , Radioisótopos de Xenônio/farmacocinética
4.
Nucl Med Commun ; 31(9): 821-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20936746

RESUMO

PURPOSE: Lung perfusion impairment in patients with pulmonary arteriovenous fistula (AVF) was evaluated by automated deep inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. METHODS: Participants were 14 patients with a single (N=6) or multiple nodular AVFs (N=8) diagnosed by contrast-enhanced CT scan and/or pulmonary angiography. After the injection of 185MBq Tc-99m-macroaggregated albumin, a whole-body scan was obtained to quantify an intrapulmonary right-to-left shunt. Subsequently, DIBrH SPECT was obtained using the continuous rotating acquisition mode of a dual-headed SPECT system, which was automatically coregistered with DIBrH CT. The anatomic relationship between AVF and perfusion defects was assessed on the fusion images. RESULTS: The whole-body scan depicted systemic organs indicating the presence of an intrapulmonary right-to-left shunt in all the patients. DIBrH SPECT showed 34 perfusion defects in these patients, which were located at the AVF and in the surrounding lungs of the AVF on the fusion images, regardless of the absence of morphologic abnormality on CT in all the patients. These defects were considered to be caused by the 'steal phenomenon' associated with the high and fast pulmonary arterial flow to each AVF, which were more extensive and severe in the multiple AVFs compared with a single AVF (P=0.0012), occasionally extending to the entire lobe with AVF or even to the adjacent lobe. In five patients, the fusion images detected a total of six tiny AVFs with unexpectedly extensive 'steal phenomenon'-induced defects, which had been missed by other radiological imaging techniques. The summed value of the shunt index estimated by the whole-body scan and the lung perfusion defect extent estimated by DIBrH SPECT was significantly correlated with PaO2 in all the patients (P < 0.0001), with a better correlation compared with the shunt index alone. CONCLUSION: In addition to the right-to-left shunt, 'steal phenomenon'-induced perfusion defects are common in the surrounding lung of pulmonary nodular AVF and cause hypoxemia. DIBrH SPECT-CT fusion images contribute to the objective evaluation of 'steal phenomenon'-induced lung perfusion impairment in AVF and the detection of tiny, subtle AVFs that may be missed by other radiological imaging techniques.


Assuntos
Fístula Arteriovenosa/diagnóstico por imagem , Pulmão/irrigação sanguínea , Circulação Pulmonar , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Fístula Arteriovenosa/fisiopatologia , Automação , Criança , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Respiração
5.
Nucl Med Commun ; 31(7): 673-81, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20418789

RESUMO

PURPOSE: Cross-sectional lung ventilation (V)-perfusion (Q) imbalance in primary pulmonary arterial hypertension (PAH) and passive pulmonary hypertension (PH) was characterized by automated V/Q single-photon emission computed tomography (SPECT). MATERIALS AND METHODS: Technegas/macro-aggregated albumin SPECT-derived V/Q SPECT and V/Q profile were automatically built to characterize cross-sectional lung V-Q imbalance in 12 patients with primary (idiopathic or familial) PAH and 15 patients with passive PH associated with left ventricular dysfunction or failure. The abnormality of V/Q distribution in these patients was correlated with PaO2 and pulmonary arterial pressure and with lung morphologic changes on computed tomography (CT). RESULTS: Markedly low V/Q ratios (reverse V-Q mismatch) in the background lungs with heterogeneous V/Q distribution was seen in 12 of the 12 (100%) patients with primary PAH and in 10 of the 15 (66%) patients with passive PH, which were predominantly seen in the upper lung zone. Including these regions with reverse V-Q mismatch, the V/Q profile frequently showed flattened peaks with asymmetric and broadened V/Q distribution in all patients, with significant correlation between the standard deviation of V/Q ratios in the entire lungs and PaO2 and mean pulmonary arterial pressure (both; P<0.01). At the regions of the lungs with reverse V-Q mismatch, bronchial lumens compressed by dilated pulmonary arteries and heterogeneous lung attenuations were frequently seen on CT. CONCLUSION: Patients with primary PAH and passive PH seem to characteristically have a high prevalence of reverse V-Q mismatch indicative of an inadequate hypoxic vasoconstriction reflex on V/Q SPECT, frequently accompanied with heterogeneous lung attenuations and compressed airways on CT.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Tomografia Computadorizada de Emissão de Fóton Único , Relação Ventilação-Perfusão , Adulto , Idoso , Albuminas , Automação , Estudos de Casos e Controles , Feminino , Humanos , Pulmão/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Pertecnetato Tc 99m de Sódio , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Ann Nucl Med ; 24(4): 269-77, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20340054

RESUMO

PURPOSE: Tc-99m-Technegas-MAA single photon emission computed tomography (SPECT)-derived ventilation (V)/perfusion (Q) quotient SPECT was used to assess lung V-Q imbalance in patients with pulmonary emphysema. METHODS: V/Q quotient SPECT and V/Q profile were automatically built in 38 patients with pulmonary emphysema and 12 controls, and V/Q distribution and V/Q profile parameters were compared. V/Q distribution on V/Q quotient SPECT was correlated with low attenuation areas (LAA) on density-mask computed tomography (CT). Parameters of V/Q profile such as the median, standard deviation (SD), kurtosis and skewness were proposed to objectively evaluate the severity of lung V-Q imbalance. RESULTS: In contrast to uniform V/Q distribution on V/Q quotient SPECT and a sharp peak with symmetrical V/Q distribution on V/Q profile in controls, lung areas showing heterogeneously high or low V/Q and flattened peaks with broadened V/Q distribution were frequently seen in patients with emphysema, including lung areas with only slight LAA. V/Q distribution was also often asymmetric regardless of symmetric LAA. All the proposed parameters of V/Q profile in entire lungs of patients with emphysema showed large variations compared with controls; SD and kurtosis were significantly different from controls (P < 0.0001 and P < 0.001, respectively), and a significant correlation was found between SD and A-aDO2 (P < 0.0001). CONCLUSIONS: V/Q quotient SPECT appears to be more sensitive to detect emphysematous lungs compared with morphologic CT in patients with emphysema. SD and kurtosis of V/Q profile can be adequate parameters to assess the severity of lung V-Q imbalance causing gas-exchange impairment in patients with emphysema.


Assuntos
Pulmão/irrigação sanguínea , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/fisiopatologia , Ventilação Pulmonar , Tomografia Computadorizada de Emissão de Fóton Único , Automação , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Reprodutibilidade dos Testes , Pertecnetato Tc 99m de Sódio , Agregado de Albumina Marcado com Tecnécio Tc 99m
7.
Ann Nucl Med ; 22(5): 339-47, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18600410

RESUMO

OBJECTIVE: Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. METHODS: Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. RESULTS: DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P < 0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P < 0.05). CONCLUSIONS: DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease.


Assuntos
Circulação Pulmonar , Enfisema Pulmonar/diagnóstico , Técnica de Subtração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Estatística como Assunto
9.
Eur J Radiol ; 67(3): 472-80, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17905552

RESUMO

PURPOSE: The relation between lung perfusion defects and intravascular clots in acute pulmonary thromboembolism (PTE) was comprehensively assessed on deep-inspiratory breath-hold (DIBrH) perfusion SPECT-computed tomographic pulmonary angiography (CTPA) fusion images. MATERIALS AND METHODS: Subjects were 34 acute PTE patients, who had successfully performed DIBrH perfusion SPECT using a dual-headed SPECT and a respiratory tracking system. Automated DIBrH SPECT-CTPA fusion images were used to assess the relation between lung perfusion defects and intravascular clots detected by CTPA. RESULTS: DIBrH SPECT visualized 175 lobar/segmental or subsegmental defects in 34 patients, and CTPA visualized 61 intravascular clots at variable locations in 30 (88%) patients, but no clots in four (12%) patients. In 30 patients with clots, the fusion images confirmed that 69 (41%) perfusion defects (20 segmental, 45 subsegmental and 4 lobar defects) of total 166 defects were located in lung territories without clots, although the remaining 97 (58%) defects were located in lung territories with clots. Perfusion defect was absent in lung territories with clots (one lobar branch and three segmental branches) in four (12%) of these patients. In four patients without clots, nine perfusion defects including four segmental ones were present. CONCLUSION: Because of unexpected dissociation between intravascular clots and lung perfusion defects, the present fusion images will be a useful adjunct to CTPA in the diagnosis of acute PTE.


Assuntos
Angiografia/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Mecânica Respiratória , Técnica de Subtração
10.
J Comput Assist Tomogr ; 30(1): 83-91, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16365579

RESUMO

Regional computed tomography attenuation (CTA) alteration at perfusion defects in acute pulmonary thromboembolism (PTE) was comprehensively assessed using deep-inspiratory breath-hold SPECT-CT fusion images. Subjects were 14 acute and 9 chronic PTE patients and 13 control subjects. Regional perfusion, CTA, and intravascular clots were correlated on deep-inspiratory breath-hold SPECT-unenhanced/angiographic CT fusion images. Fusion images visualized hypo-CTA in 57% of the acute PTE patients, which preferentially occurred at extensively and severely decreased perfusion areas caused by central clots. CTA at 35 defects of acute PTE was significantly decreased compared with that of normal lungs (P<0.001), but the degree was less compared with chronic PTE (P<0.0001). Fusion images also revealed variable relationships of clots and regional perfusion/CTA in the distal lungs of each central clot. Fusion images provide important information about the actual effects of intravascular clots on peripheral perfusion/CTA and indicate that lung CTA can be decreased at perfusion defects in acute PTE.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Agregado de Albumina Marcado com Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA