Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Fish Biol ; 83(4): 1046-66, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24090562

RESUMO

Recent data on fishmeal and fish-oil supply are presented identifying key producer countries and raw material sources and distinguishing between whole fish and by-products. The conversion of these raw materials into marine ingredients is discussed and global volumes presented. This is followed by a summary of the main countries using these marine ingredients over recent years. Uses of fishmeal and fish-oil by market segment are then presented. From this, a global mass balance of inputs and outputs is derived which allows the calculation of the input-to-output ratios (fish in:fish out; FIFO) for the main aquaculture production types to be made. Current areas of focus by the industry include the need to demonstrate sustainable practice, more strategic use of marine ingredients, greater use of fishery and land-animal by-products as well as vegetable substitutes, and novel sources of essential omega-3 fats, notably the long-chain polyunsaturated fatty acids, eicosapentaenoic (EPA) and docosahexaenoic (DHA) acids. Implications are drawn for future supply prospects of fishmeal and fish-oil and their future role in aquaculture, agriculture and human health.


Assuntos
Aquicultura/economia , Óleos de Peixe/provisão & distribuição , Produtos Pesqueiros/provisão & distribuição , Animais , Aquicultura/métodos , Conservação dos Recursos Naturais/economia , Conservação dos Recursos Naturais/métodos , Ácidos Graxos Ômega-3
2.
Pharm Res ; 17(11): 1432-6, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11205739

RESUMO

PURPOSE: Simulated pharmacokinetic (PK) studies were done to determine the effect of intrinsic clearance (CL(INT)) on the probability of meeting bioequivalence criteria for extent (AUC) and rate (Cmax) of drug absorption when the absorption rate and fraction absorbed (F) were formulated either to be equivalent or to differ by 25%. METHODS: Simulated PK studies were done using a linear first-pass model with CL(INT) values ranging from 15 L/HR to 900 L/HR. Test/Reference absorption rate constants (Ka) and fraction absorbed (Fa) ratios of 1.0 or 1.25 were used for all simulations. The impact of the value of CL(INT) and its intrasubject variation upon the probability of concluding bioequivalence at the two different Ka and F ratios was studied. Additionally, the effect of fraction metabolized i.v., (Fm) on the probabilities of concluding equivalence was studied at values of 0.25 and 0.75. RESULTS: When CL(INT) values were raised above those for liver blood flow, the frequency of trials in which bioequivalence was correctly declared decreased when parent AUC was used as a bioequivalence criterion. Only when CL(INT) exceeded liver blood flow did the metabolite become important in assessing extent of absorption. CONCLUSIONS: The Cmax for the parent drug provided the most accurate assessment of bioequivalence. The Cmax for the metabolite was insensitive to changes related to rate of input, and when CL(INT) exceeded liver blood flow, evaluation of the metabolite Cmax data may lead to a conclusion of bioequivalence for products that were not.


Assuntos
Modelos Biológicos , Equivalência Terapêutica , Adolescente , Adulto , Antidepressivos Tricíclicos/sangue , Antidepressivos Tricíclicos/farmacocinética , Ensaios Clínicos como Assunto , Clomipramina/sangue , Clomipramina/farmacocinética , Simulação por Computador , Preparações de Ação Retardada , Antagonistas dos Receptores Histamínicos H1/sangue , Antagonistas dos Receptores Histamínicos H1/farmacocinética , Humanos , Dinitrato de Isossorbida/sangue , Dinitrato de Isossorbida/farmacocinética , Cinética , Fígado/metabolismo , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Terfenadina/sangue , Terfenadina/farmacocinética , Vasodilatadores/sangue , Vasodilatadores/farmacologia
4.
Pharm Res ; 16(1): 130-4, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9950291

RESUMO

PURPOSE: To compare the applicability and accuracy of truncated area (AUCt; where t represents truncated time) versus area to the last quantifiable time point [AUC(O-T)] for assessing bioequivalence. Drugs with either very low or very high intra-subject variability in clearance (CL) were selected for study. Clearance variability was defined by the number of subjects with a quantifiable plasma value (Cp) at each collection time from 24 hrs to last collection time (T). METHODS: Data for amiodarone and danazol, drugs with different distributions of subject CL were examined. For amiodarone, the number of subject samples observed (test + reference) at the time of the last quantifiable concentrations was 60 at 240 hrs(T), 16 at 144 hrs and 4 at 96 hrs: while danazol had 4 at 96 hr(T), 3 at 72 hrs, 16 at 60 hrs, 7 at 48 hrs, 14 at 36 hrs, 11 at 24 hrs, 13 and 2 at 16 and 12 hrs, respectively. Simulations (Scenarios A and B) were performed to obtain populations (N = 24) with CL patterns similar to those of amiodarone and danazol. For scenario A (CL pattern similar to amiodarone), log-normally distributed CL values (28.8 L/HR) with intra-subject coefficient of variation (CV) of 25%, 40% and 60% gave the desired CL pattern. Scenario B (CL pattern similar to danazol) required that a subpopulation with an increase in CL of 40% from baseline (i.e., 40.32 L/HR) in 5%, 10% and 20% of the population represent the desired distribution. Power was evaluated by the percentage of times the simulated trials were declared bioequivalent (i.e., the number of times the test vs. reference 90% CI was within 80-125%), while accuracy was determined when the true difference in fraction absorbed (i.e., 1.25) was within the CI. Each simulation was repeated 300 times. RESULTS: The simulation results for Scenario A indicated that the statistical results using truncated area (AUCt) had power and accuracy equivalent to that obtained using the AUC(O-T) metric. However, results for Scenario B indicated that AUCt had less power and accuracy than that obtained using AUC(0-T). The confidence interval (CI) for amiodarone was the same whether AUC (0-T) or AUCt was used as the metric for extent, while for danazol, the AUC(0-T) and AUCt differed in the lower limit by 7%. CONCLUSIONS: The truncated area, AUCt, has the greatest power and accuracy when the population clearance is such that most subjects have measurable plasma concentrations at last collection time(T), resulting in a proportional loss of data from each subject.


Assuntos
Amiodarona/farmacocinética , Simulação por Computador , Danazol/farmacocinética , Absorção Intestinal , Adulto , Análise de Variância , Estudos Cross-Over , Feminino , Humanos , Pessoa de Meia-Idade , Método de Monte Carlo , Reprodutibilidade dos Testes , Equivalência Terapêutica
6.
Pharm Res ; 15(7): 1077-84, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9688063

RESUMO

PURPOSE: Two methods to confirm attainment of steady-state conditions in multiple-dose bioequivalence studies are described and evaluated: (1) the Cmin method and (2) the Area Below the Cmin plasma-concentration-versus-time-curve method (ABCM method). METHODS: Cmin Method-After repetitive drug administration to presumed steady-state, successive trough, or Cmin, values are evaluated to determine if they are equal. ABCM Method-The ABCM of successive doses from dose two to presumed steady-state [ABCM(ss)] are divided by the ABCM for the first dose, ABCM(t), to give ABCM(ss)/ ABCM(t)=R, which describes the increase in ABCM(n) with successive doses. The quantity, R, is then divided by an accumulation ratio to render the value independent of intra-subject clearance differences. Monte Carlo simulations were done to test the effects of data error and slow-clearing subpopulations on the method's performance. Data from multiple-dose bioequivalence studies were evaluated using confidence intervals for both methods to determine how well each predicted steady-state for immediate-release and controlled-release drug products. RESULTS/CONCLUSIONS: The Cmin method more accurately predicted the attainment of steady-state conditions for immediate-release formulations compared to the ABCM method. Conversely, the ABCM procedure more accurately predicted the attainment of steady-state conditions for controlled-release formulations compared to the Cmin method. The simulation results were further supported by the experimental data.


Assuntos
Método de Monte Carlo , Farmacocinética , Equivalência Terapêutica , Adolescente , Adulto , Antialérgicos/administração & dosagem , Antialérgicos/farmacocinética , Antimaláricos/administração & dosagem , Antimaláricos/farmacocinética , Compartimentos de Líquidos Corporais , Clorfeniramina/administração & dosagem , Clorfeniramina/farmacocinética , Simulação por Computador , Estudos Cross-Over , Preparações de Ação Retardada , Humanos , Masculino , Computação Matemática , Quinidina/administração & dosagem , Quinidina/farmacocinética
7.
Ophthalmic Physiol Opt ; 17(3): 187-95, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9196660

RESUMO

In January 1993 the Royal Group of Hospitals Trust, which employs approximately 5000 staff, implemented the Health and Safety (Display Screen Equipment) Northern Ireland Regulations (1992). During 1994 all regular display screen equipment users were offered a vision screening test. In total 571 employees were screened using computerized vision screening software (City Visual Systems Ltd). Risk assessments were completed for 293 display screen work-stations. One hundred and twelve full eye examinations, carried out by optometrists, were performed on those who failed vision screening and on those who specifically requested an optometric assessment. Results indicate that whereas the proportion of users experiencing visual and general symptoms differed markedly from department to department (28-82%), the median number of individuals failing the screening test was 25% (range 9-40%). Those involved in uninterrupted display screen equipment work for prolonged periods reported visual and general work-related symptoms twice as frequently as those who spent less time working with DSE. The outcome of full eye examinations confirmed that less than 5% of display screen users required spectacles solely for display screen use. Work-station analysis indicated that ergonomic problems were common. The authors conclude that the successful management of health risks from display screen equipment requires simultaneous attention to work-place design, working patterns and eye care.


Assuntos
Apresentação de Dados , Seleção Visual , Adolescente , Adulto , Terminais de Computador , Feminino , Hospitais de Ensino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/diagnóstico , Doenças Profissionais/prevenção & controle , Medição de Risco , Fatores Sexuais , Fatores de Tempo , Transtornos da Visão/diagnóstico , Transtornos da Visão/prevenção & controle , Acuidade Visual , Campos Visuais
8.
Pharm Res ; 12(11): 1634-41, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8592662

RESUMO

PURPOSE: A Monte Carlo simulation study was done to investigate the effects of high intrasubject variation in clearance (CL), and volume of distribution (V) on the calculation of the 90% confidence interval (CI) for Cmax for single dose and multiple dose studies. METHODS: Simulations were done for both immediate release and sustained release scenarios. The simulated data were compared with clinical data from bioequivalence studies performed on indomethacin and verapamil. RESULTS: Previous reviews and simulations have shown that the probability of failure for the Cmax for single dose studies was always greater than that for multiple dose studies. However, the results for the simulated scenarios currently investigated indicate that if intra-subject (period-to-period) variation in CL and V is high (% CV's above 25%, and 12%, respectively), multiple dose studies can exhibit a higher probability of failure for Cmax than do single dose studies. Furthermore, Cmax values from studies performed with a sustained release scenario are more sensitive to changes in Ka, CL, and V than are results of studies on immediate release products. As an example, the probability of failure for immediate release products in simulated single dose studies is about 11% and 21% when the mean difference in Ka is 10% and 20%, respectively; while, the probability of failure for multiple dose studies is about 36% regardless of the difference in Ka. The corresponding values for the probability of failure for sustained release products were 25%, 53% for single dose studies and 39% for multiple dose studies. The simulations also indicate that changes in the fraction absorbed have a greater effect on the estimation of Cmax in multiple dose regimens than in single dose studies. CONCLUSIONS: The results from these investigations indicate that multiple dose studies do not necessarily always reduce variability in Cmax.


Assuntos
Indometacina/farmacocinética , Absorção Intestinal , Método de Monte Carlo , Equivalência Terapêutica , Verapamil/farmacocinética , Absorção , Adolescente , Adulto , Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/farmacocinética , Disponibilidade Biológica , Bloqueadores dos Canais de Cálcio/administração & dosagem , Bloqueadores dos Canais de Cálcio/farmacocinética , Simulação por Computador , Preparações de Ação Retardada , Humanos , Indometacina/administração & dosagem , Cinética , Masculino , Pessoa de Meia-Idade , Verapamil/administração & dosagem
9.
Pharm Res ; 12(5): 700-8, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7479556

RESUMO

Simulations were conducted to address the question of whether metabolite data are required for bioequivalence evaluation of immediate release formulations with drugs exhibiting linear pharmacokinetics and first-pass effect. Plasma level-time profiles were generated for parent drug and metabolite using relevant rate constants obtained from a bivariate normal distribution and designated random error. Simulation results showed that the need for metabolite data (Cmax) in the assessment of bioequivalence depends on the relative variability between the absorption process of the drug and first-pass route for metabolite(s). The importance of metabolite Cmax data in the evaluation of rate of availability is clearly demonstrated for drugs with a high degree of intra-subject variation in the first-pass metabolism compared to the absorption process of the drug. Under such conditions, a wider confidence interval was found for the metabolite rather than parent drug. Opposite results were obtained when the intra-subject variance was high for drug absorption relative to first-pass effect. Discrepancies were observed for the scenarios in which the elimination pathway of the metabolite is more variable than the absorption process of the drug. The simulation results were in agreement with real bioequivalence data. It is thus recommended that, in the absence of the information on the relative variability of absorption and first-pass process, both parent drug and metabolite data be included for documentation of bioequivalence, should the metabolite(s) play an important role in the determination of efficacy and safety of the drug.


Assuntos
Preparações Farmacêuticas/metabolismo , Farmacocinética , Absorção , Análise de Variância , Simulação por Computador , Humanos , Métodos , Equivalência Terapêutica
10.
Pharm Res ; 11(9): 1330-6, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7816765

RESUMO

The purpose of this study was to evaluate the relative performance and usefulness of single dose (SD) and multiple dose (MD) regimens for bioequivalence (BE) determination. Drugs such as indomethacin, procainamide, erythromycin, quinidine, nifedipine were tested for BE under SD and MD dose regimens. Drugs characterized by low accumulation indices (AI) showed virtually no change in the 90% confidence interval (CI) of AUC and CMAX upon multiple dosing. On the other hand, drugs with higher AI appeared to have smaller CI at steady-state. For example, the CI range of AUC and CMAX of quinidine (AI of 1.54) decreased from 26 to 12 and from 22 to 12, respectively, upon multiple dosing. A Monte Carlo simulation study of SD and MD bioequivalence trials was performed. The probability of failing the bioequivalence test was evaluated for several situations defined by different levels of variability and correlation in ka constants, presence or absence of inter- and/or intra-individual variability in clearance (CL) and volume of distribution (V), and different degrees of accumulation. All the possible combinations of these factors were tested with SD and MD study designs. All simulations used 1000 data sets with 30 subjects in each data set for a total of 144 unique designs (total of 144,000 simulations of bioequivalence trials). Upon multiple dosing, narrowing of CI ranges was observed for drugs simulated to have high AI high variability and a large difference in absorption constants (ka) between test and reference formulations.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Equivalência Terapêutica , Adolescente , Adulto , Estudos Cross-Over , Eritromicina/administração & dosagem , Eritromicina/farmacocinética , Humanos , Indometacina/administração & dosagem , Indometacina/farmacocinética , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Nifedipino/administração & dosagem , Nifedipino/farmacocinética , Procainamida/administração & dosagem , Procainamida/farmacocinética , Quinidina/administração & dosagem , Quinidina/farmacocinética
11.
Pharm Res ; 8(1): 25-32, 1991 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2014204

RESUMO

The estimation of bioequivalency using metabolite data was investigated for immediate release formulations with drugs exhibiting linear pharmacokinetics and no first-pass effect. This was accomplished by generating parent drug and metabolite plasma level profiles assuming formation and excretion rate-limited pharmacokinetic models with absorption rate constants obtained from bivariate normal distributions and designated random errors. Simulation results indicated that bioequivalence determination using Cmax of parent drug and metabolite was independent of the metabolite models as evaluated by confidence interval approach. However, a clear difference with respect to the outcome of bioequivalence evaluation arises depending upon the utilization of Cmax values for the parent drug and metabolite. The major reason for this disparity was attributed to the minimal effect of the absorption process for the parent drug on the formation of the metabolite. This phenomenon results in an apparent lower intrasubject variability for Cmax of the metabolite and, in turn, a tighter confidence interval for Cmax of the metabolite in comparison with the parent drug. The simulated results have been found to be in agreement with the bioequivalency data for acetohexamide, allopurinol, procainamide, and sulindac. In all cases, the interval of the 90% confidence limit for Cmax of the metabolite is always smaller than that of the parent drug, regardless of the drug pharmacokinetics and the level of error contained in the data.


Assuntos
Disponibilidade Biológica , Farmacocinética , Acetoexamida/farmacocinética , Adolescente , Adulto , Alopurinol/farmacocinética , Análise de Variância , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Procainamida/farmacocinética , Sulindaco/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA